Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"Beam position monitor"”
-
Characterization of a Beam Position Monitor for Linear Accelerators
… the efficiency of Mo-99 yield, a non-interfering Beam Position Monitor (BPM) system was developed that measures the time-dependent centering of the Bremsstrahlung producing electron beam. The Beam Positioning Monitor is comprised of 4 capacitive pickups positioned at 90 degrees to each other …
-
A Phase Space Beam Position Monitor for Synchrotron Radiation
The stability of the photon beam position on synchrotron beamlines is critical for most if not all synchrotron radiation experiments. On wiggler and bend magnet beamlines, the vertical position is most critical due to the large horizontal width of the beam. The position of the beam at the …
-
Development of a beam position monitor for co-propagating electron and proton beams
… technical challenges due to the use of several beams and the beam parameters involved. To exploit these new technologies, these technical challenges need to be addressed. Innovative beam instrumentation is to be devised, to allow these acceleration experiments to become operational accelerators. …
-
Transverse beam dynamics studies from turn-by-turn beam position monitor data in the ALBA storage ring
LBA es una fuente de luz de sincrotrón de tercera generación, en funcionamiento desde 2011, al servicio de una comunidad científica e industrial nacional e internacional. Varios laboratorios (lineas de luz) explotan la radiación electromagnética hasta los rayos X, para una amplia gama de …
-
Development of a beam position monitor based on Cherenkov diffraction radiation for the AWAKE experiment at CERN
… closely in time and space within the common beam-line before the entrance of the plasma cell. The proton bunches possess a bunch charge of 48 nC and a RMS bunch length of 200 − 400 ps , while the electron bunches carry a much lower bunch charge of ∼ 600 pC and have a few ps bunch length. The …
-
A REAL TIME PHASE SPACE BEAM SIZE AND DIVERGENCE MONITOR FOR SYNCHROTRON RADIATION
My prior work has shown that an electron beam position and angle monitoring system was able to measure the electron source position and angle at a single location in a beamline at a synchrotron source. This system, a phase space ̶ Beam Position Monitor (ps-BPM), relies on a monochromator to prepare …
-
Front end x-ray beam position monitors at the Canadian Light Source
The development of X-ray Beam Position Monitors (XBPM) used on the Canadian Light Source front ends is described in this thesis, from the design concepts to the practical implementation and commissioning. Surveyed into position to provide a fiducialized point of origin for incoming synchrotron …
-
The Interaction Point Collision Feedback System at the International Linear Collider and its sensitivity to expected electromagnetic backgrounds
… (ILC). This is proposed to include a stripline beam position monitor (BPM) positioned 3 m from the Interaction Point (IP). The BPM is required to be able to measure the position of the outgoing electron or positron beam with a resolution of 1 m. Prototype feedback systems have been built and …
-
A comparative study of the existing methods for their suitability to beam stabilization in Storage Ring at Canadian Light Source
The stabilization of electron beam in the Storage Ring (SR) is an important task in the 3rd generation synchrotron facility worldwide. Deviations in the position and angle of electron beam with respect to a desired orbit must be below 10% of the beam size. This requirement corresponds to about 3 μm …
-
GaN radiation detectors for particle physics and synchrotron applications
… detectors for radiation hard, biological and monitoring applications. Gallium nitride (GaN) was investigated as a radiation hard particle detector and as an UV light detector while the properties of single crystal diamond as a soft x-ray beam position monitor were assessed. Photolithographic …
-
Development of the Beam Position Monitors for the Diagnostics of the Test Beam Line in the CTF3 at CERN
… for Particle Accelerators, so called Beam Diagnostics. It is presented the development of a series of electro-mechanical devices called Inductive Pick-Ups (IPU) for Beam Position Monitoring (BPM). A full set of 17 BPM units (16 + 1 spare), named BPS units, were built and installed into …
-
Beam position monitoring in the clic drive beam decelerator using stripline technology
… center of mass energy region, is based on a two-beam operation principle: instead of using active elements (klystrons), the necessary RF power to accelerate the Main Beam (MB) is obtained from the deceleration of a high-current, moderate energy Drive Beam (DB) in the so-called Power Extraction …
-
Etudes de la dynamique faisceau et d’un diagnostic de position pour les lignes de haute énergie du projet MINERVA
… de la conception des lignes de haute énergie positionnées en aval du LINAC sont présentées. Ces lignes de transfert, d’une longueur totale de l’ordre de 120 m, permettent de délivrer le faisceau d’énergie nominale de 100 MeV et d’intensité 4 mA sur trois sites : une installation recevant une …
-
Dynamique des faisceaux dans la section finale de focalisation du futur collisionneur linéaire
… à l’IP, et stabiliser de l’ordre du nanomètre la position verticale du faisceau à l’IP. Depuis 2014, une taille de 44 nm avec un nombre de particules d’environ 0.1 × 10^10 par paquet est atteint de manière regulière.Des cavités radio-frequence seront utilisées pour la stabilisation du faisceau, et …