Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"Bench Top Model"”.

  1. Assessing Arterial Compliance: Utilizing a Surrogate Arm Bench Top Model for Oscillometric Blood Pressure Monitoring

    … an adaptation of the Yong-Geddes Surrogate Arm model, composed of a blood pressure cuff, artificial artery, pressure transducers, and flow to replicate physiological conditions to validate oscillometric non-invasive blood pressure measurement methods. The experiment phases included tube, blood …

    calpoly Repository record for Assessing Arterial Compliance: Utilizing a Surrogate Arm Bench Top Model for Oscillometric Blood Pressure Monitoring (opens in a new tab)

  2. Analysis of Arterial Compliance Using a Surrogate Arm Bench Top Model for the Validation of Oscillometric Blood Pressure Methods

    … the accuracy of measurements made through the bench top model. The study was performed to perceive the effectiveness of the model as a tool for validating non-invasive blood pressure detection monitors. Three stages of testing were performed to gather pressure and volume data from an artificial …

    calpoly Repository record for Analysis of Arterial Compliance Using a Surrogate Arm Bench Top Model for the Validation of Oscillometric Blood Pressure Methods (opens in a new tab)

  3. Noninvasive Measurement of Arterial Compliance with a Blood Pressure Cuff Using a Surrogate Arm Bench Top Model for Oscillometric Use

    A surrogate arm model was created that is capable of being used for oscillometry. This model is capable of being used as a bench top model for blood pressure cuff devices. The arm consists of endplates and internal supports that are 3D printed with ABS, a silicone rubber outer sleeve, and …

    calpoly Repository record for Noninvasive Measurement of Arterial Compliance with a Blood Pressure Cuff Using a Surrogate Arm Bench Top Model for Oscillometric Use (opens in a new tab)

  4. The Role of Hemodynamics in Determining Drug Deposition in Stent-Based Delivery

    … framework comprising computational and bench-top models has been formulated to explore the relative contributions of key hemodynamic parameters intrinsic to a vascular bed. Using a novel, dynamically similar bench-top model, we determine that arterial drug patterns are sensitive to the …

    unsw Repository record for The Role of Hemodynamics in Determining Drug Deposition in Stent-Based Delivery (opens in a new tab)

  5. Studies of dietary nitrate induced nitrosative stress in the upper gastrointestinal tract

    … been shown at the gastroesophageal junction. A bench top model has been developed to explore the chemistry occurring in an aqueous phase, representing the lumen at the gastroesophageal junction, after the addition of nitrite. Within this model an adjacent lipid phase has been created. The lipid …

    glasgow Download PDF for Studies of dietary nitrate induced nitrosative stress in the upper gastrointestinal tract (opens in a new tab)

  6. Cerebrospinal fluid mechanics during and after experimental spinal cord injury

    … aim of this thesis was to develop a large animal model and a benchtop model of human SCI, and to use these to characterise (1) the pressure response of the CSF during the SCI event, (2) the effect of CSF thickness on mechanical indicators of injury severity, and (3) the pressure differentials and …

    ubc Repository record for Cerebrospinal fluid mechanics during and after experimental spinal cord injury (opens in a new tab) Download PDF for Cerebrospinal fluid mechanics during and after experimental spinal cord injury (opens in a new tab)

  7. Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke

    … in success rate of thrombus removal in a bench-top model was from 67% to 100%. This hybrid device is then tested in a porcine model, in which it is able to restore blood flow in an artery occluded with a thrombus nearly 3 times its working length. In addition to being utilized as a …

    tamu Repository record for Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke (opens in a new tab)

  8. An Investigation of the Ward Leonard System for Use in a Hybrid or Electric Passenger Vehicle

    … HEV vehicles was also research and identified. A bench top model of the Ward Leonard system was tested validating the Control Factor metric. The Ward Leonard system is capable of reducing the controller size by 77% and potentially reducing its cost by 68% or more. This work also provides …

    byu Repository record for An Investigation of the Ward Leonard System for Use in a Hybrid or Electric Passenger Vehicle (opens in a new tab) Download PDF for An Investigation of the Ward Leonard System for Use in a Hybrid or Electric Passenger Vehicle (opens in a new tab)

  9. Computational Modelling of Flow and Mixing in the Proximal Small Intestine

    … contact with the absorptive surfaces. In silico models of intestinal motility such as computational fluid dynamics (CFD) models provide a better understanding of the fluid flow patterns found within the duodenum compared to existing in vitro simulator studies and in vivo studies. Existing CFD …

    auckland-ms Repository record for Computational Modelling of Flow and Mixing in the Proximal Small Intestine (opens in a new tab)

  10. A Bench Top Study Of The Optimization Of Lvad Cannula Implantation To Reduce Risk Of Cerebral Embolism

    Physical bench top experiments are performed to validate and complement ongoing computational fluid dynamics (CFD) analyses of ventricular assist device (VAD) circulation. VADs are used in patients whose hearts do not function to their maximum potential due advanced stages of heart disease and, …

    ucf Repository record for A Bench Top Study Of The Optimization Of Lvad Cannula Implantation To Reduce Risk Of Cerebral Embolism (opens in a new tab)

  11. Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system

    … explores the applications of PCD-CT using a bench-top system, offering insights into its potential benefits over conventional CT systems. Despite its limitations in fully representing a clinical CT system, the bench-top model provides flexibility in assessing clinically useful features. This …

    uvic Repository record for Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system (opens in a new tab)

  12. Influence of dietary antioxidants on luminal nitrite chemistry under conditions simulating the gastro-oesophageal junction

    … were performed in a newly designed closed bench-top model reproducing the chemical environment occurring at the human gastro-oesophageal junction. Each of the experiments was performed with and without NaSCN at different pH values (1.5, 2.5 and 3.0) under both aerobic and anaerobic …

    glasgow Download PDF for Influence of dietary antioxidants on luminal nitrite chemistry under conditions simulating the gastro-oesophageal junction (opens in a new tab)

  13. Mitigation of intrarenal pressure in retrograde intrarenal surgery with a novel isoprenaline eluting guidewire

    … guidewire intended for the administration of topical isoprenaline, a beta-receptor agonist, to the genitourinary system. This is the first study to report the delivery of isoprenaline using a drug-eluting guidewire. This dissertation comprises six chapters. The initial five chapters each have …

    cape-town Repository record for Mitigation of intrarenal pressure in retrograde intrarenal surgery with a novel isoprenaline eluting guidewire (opens in a new tab)

  14. The microstructure of synthetic aggregate produced from waste materials and its influence on the properties of concrete

    … raw materials were extruded and fired in a small bench top model Trefoil rotary kiln. Various temperature profiles were simulated and the effects of firing condition on the water absorption, relative density and mineralogical and microstructural evolution of the synthetic aggregate were …

    whiterose Download PDF for The microstructure of synthetic aggregate produced from waste materials and its influence on the properties of concrete (opens in a new tab)

  15. Biomechanical investigation of a new core suture configuration and a new peripheral repair method for zone II flexor tendon injuries : an experimental ex vivo study

    … of the anatomy in this area. Poor results postoperatively are costly and lead to even more complex second operations, resulting in long time periods where patients are unable to use their hands fully. The repair techniques are numerous, as are the materials available for such repairs, and the …

    strathclyde Repository record for Biomechanical investigation of a new core suture configuration and a new peripheral repair method for zone II flexor tendon injuries : an experimental ex vivo study (opens in a new tab)

  16. HUMAN EYE RESPONSE TO SIMULTANEOUS OPTICAL DEFOCUS

    … myopic eyes, integrating evidence from animal models, short-term clinical trials, and bench-top optical characterization. First, a systematic review exploring the impact of simultaneous optical defocus in animal studies (Chapter 2) was conducted to establish the theoretical framework for how …

    unsw Repository record for HUMAN EYE RESPONSE TO SIMULTANEOUS OPTICAL DEFOCUS (opens in a new tab) Embargoed