Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 30 for “"Benchtop model"”
-
Effects of Larynx Preservation Method on Phonation Threshold Pressure in an Excised Porcine Benchtop Model
Several studies involving excised animal larynges have been performed to simulate the structural and physiological properties of the human larynx. The most common way to preserve the laryngeal tissue being studied is by immersing it in a 0.9% isotonic saline solution and then flash freezing it. …
-
Effects of Larynx Preservation Method on Phonation Threshold Flow in an Excised Porcine Benchtop Model
An excised animal larynx model has been used in many studies to better understand the physiological and anatomical properties of the human larynx. One difference between an ex vivo model and an in vivo model is that ion loss occurs postmortem. To compensate for this in the excised model, …
-
Variability of the Aerodynamic Measures of Leporine Larynges Exposed to Inhaled Corticosteroids
… measures of phonation utilizing a traditional benchtop model with leporine larynges. The motivation for this study was based on the increase of voice disorders associated with IC use in recent years. The aerodynamic measures examined were phonation threshold pressure (PTP), phonation threshold …
-
The Reversibility of Effects of Combination Inhaled Corticosteroids on Sustained Phonation Pressure and Flow in Ex Vivo Rabbit Larynges
… of ICs may be induced and then reversed, using a benchtop model and rabbit larynges measuring sustained subglottic pressure and airflow. Eighteen rabbits were assigned randomly to 5 subgroups, including baseline, induction experimental, induction control, reversibility experimental, and …
-
Developing a Skin Phantom for the Testing of Biowearables
… need in the biowearables industry for a benchtop model that can accurately emulate the perspiration mechanism and corresponding impedance vs. frequency spectra of skin. This model, or skin phantom, could increase the efficiency and accuracy of early-stage testing of biowearables, as well …
-
Novel Regenerative Shock Absorber for Electric Vehicle Applications
… develop a methodology by which an RSA could be modeled to fit a given application by simulating both the damping effect and the generated voltage. The developed system is a combination of a Rotary Regenerative Shock Absorber (RRSA), in the form of a DC motor, and mechanical methods of motion …
-
Identification and Classification of New Psychoactive Substances Using Raman Spectroscopy and Chemometrics
… of the product i.e. ‘street-like’ mixtures. Five models were developed, and three of these provided an insight into the identification and classification of NPS depending on their purity. These are: the ‘NPS and non-NPS/benchtop’ model, the ‘NPS reference standards/handheld’ model and the ‘NPS and …
-
Testing of a Novel Piezoelectric Material and Its Implementation in a Non-Invasive Contractile Force Measuring Heart-on-Chip Device
… and signaling environment of the heart on a benchtop model. This technology allows researchers to study heart diseases and new drug therapeutic strategies with more physiological relevance to the human heart than animal models and simple cell culture systems. These heart on chip devices are …
-
Development of New Treatment Modalities for Kidney/Ureter Stones
… different sizes and types of kidney stones are modeled inside the ureter and their effects on the urine flow and pressure on the ureter wall are studied. It is concluded that in addition to the stone size, different stone shapes result in different pressures on the ureter wall. In the second …
-
Optimizing the capabilities of the visible kidney system to expand its applicatons for preclinical benchtop testing and physician training
… The Visible Kidney™ preclinical benchtop model is an ongoing IPK model being developed to recreates human-use conditions. This model has been used to evaluate kidney viability, functionality and means to improve and sustain such. The stationary model was re-designed to maximize …
-
Aerodynamic Measurement Stability During Rabbit Versus Pig Benchtop Phonation
… parameters in a traditional excised larynx benchtop model. Specifically, the current author assessed measurement stability of leporine larynges compared to porcine larynges with the following aerodynamic metrics: phonation onset pressure (PTP; cmH2O), phonation onset flow (PTF; L/m), …
-
Cerebrospinal fluid mechanics during and after experimental spinal cord injury
… aim of this thesis was to develop a large animal model and a benchtop model of human SCI, and to use these to characterise (1) the pressure response of the CSF during the SCI event, (2) the effect of CSF thickness on mechanical indicators of injury severity, and (3) the pressure differentials and …
-
Effects of Inhaled Combination Corticosteroid Drugs on Aerodynamic Measures of Phonation and Visual-Perceptual Measures of Vocal Fold and Arytenoid Tissue in Excised Rabbit Larynges
… them, and harvested their larynges for benchtop research. While ensuring proper tissue preservation, researchers then finely dissected the larynges to expose the true vocal folds and run phonation trials. Dependent variables included continuous acoustic signals (Hz), subglottal pressure …
-
Finite element modeling of high frequency irreversible electroporation
… using finite element method (FEM) computational models of HFIRE to determine how specific electroporation waveform parameters affect ablation patterns in tissue and validating these results against experimental measurements. The effects of heterogeneous structures on electroporation profiles were …
-
Analysis of methods for enhancing food safety and traceability in the bulk grain industry
… study by Tenboer et al. (2023) used a small model to collect quantitative data regarding the flow behaviors of uniform granular material in a benchtop model storage bin. The previous study used glass beads in ten different colors for easy differentiation, loaded one color at a time into a …
-
Peptide targeted imaging of neutrophil invasion in cardiac tissue
The goal of this project is to engineer a benchtop model to test the efficacy of neutrophil blocking peptides, and provide a foundation for in vivo studies of peptide blocking. Current medical practices address the initial occlusion of heart flow by a surgical technique that re-opens the affected …
-
Development of a novel antibacterial silver nanocoating to reduce nosocomial infections
… a hospital sink trap community to colonise a benchtop model sink trap system. Antibiofilm activity was evident over long time periods, up to 11 days, but waned by day 25. Placement of silver nanocoated specimens in real-world sink traps in two university buildings provided little overall …
-
The Effect of Size and Location of Composite Attachments on the Extrusive Force Delivered to a Maxillary Central Incisor by a Clear Aligner
… with a clear aligner has been reported. In a benchtop model, all attachment configurations generated greater initial extrusive compared to the No attachment control. Attachment size has a positive relationship with initial extrusive force with larger attachments producing greater force. …
-
Effects of an External Oscillation Device on Phonation Threshold Pressure (PTP)
… of 12 excised pig larynges using a traditional benchtop phonation setup. For each larynx, phonation was elicited during 30 repeated trials, including 15 with and 15 without external oscillation. During the phonation trials, aerodynamic measures were collected. The outcome measure for this study …
-
Physiological and Mechanical Effects of Prosthetic Elevated Vacuum Systems in People with Transtibial Amputation
… effectiveness of EV to manage limb fluid volume, model the mechanics of EV sockets, and optimize the effects of EV. A goal of this research was to better understand how EV functions and work towards establishing clinical guidelines for its use. The clinical effectiveness of EV to manage daily …
Page 1 of 2