Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 80 for “"Biacore"”.
-
Development of BIAcore Protocols for Assessing DNA Biomolecular Interactions
No abstract prepared.
-
Biosensor-based studies on coumarins
… 7- hydroxycoumarin which was carried out on the BIAcore, an optical biosensor based on the phenomenon of surface plasmon resonance (SPR). The immunoassay was optimised and internally validated. Monoclonal antibodies were generated by somatic cell fusion using the spleens of mice immunised with a …
-
Immunoassays for the detection of illicit drugs and organophosphate pesticides
… in a competitive ELISA format and on the BIAcore (a surface plasmon resonance based optical biosensor capable of monitoring biomolecular interactions in ‘real-time’). Combinatorial single chain Fv (scFv) antibody phage display libraries were also generated to morphine-3-glucuromde …
-
Development of antibody-based assays for the detection of aflatoxins and organophosphates
… in a surface plasmon resonance-based biosensor (BIAcore), which measures biomolecular interactions in ‘real-time’. Production of hapten-protein conjugates of the organophosphate pesticides chlorpyrifos and pirimiphos, and characterisation of antichlorpyrifos antibodies were also successfully …
-
BINDING STUDIES OF EPIDERMAL GROWTH FACTOR RECEPTOR TARGETED COMPOUNDS USING SURFACE PLASMON RESONANCE
… used Surface Plasmon Resonance (SPR) technology (Biacore) to study the binding kinetics of the antibodies EGF, Cetuximab and a candidate drug P-13 with the receptor EGFR. The candidate drug P-13 was synthesized and tested on Biacore for binding kinetics. This peptide is anticipated to bind to …
-
Molecular Studies on the Interaction of Leptin With Its Receptor
… a variety of biophysical techniques, namely BiaCore and microcalorimetry. To achieve this, it was necessary to express the leptin receptor. Because the receptor cDNA was not available at the start of this project, the initial goal was to obtain the cDNA encoding the extracellular domain of …
-
Sequential injection analysis for the investigation of biomolecular interactions
… immobilized ligant. The commercially available BIAcore instrument, which uses surface plasmon resonance to evaluate biomolecular interactions, represents the standard in biosensor instrumentation. Therefore, comparison is made between results from BIAcore and those obtained with the SIB system. …
-
Synthese von Cluster-Mannosiden als multivalente Inhibitoren für den Mannose-spezifischen Makrophagen-Rezeptor
… und mittels Oberflächenplasmonenresonanz (SPR, Biacore), ELISA und Mikrokalorimetrie bezüglich ihrer biologischen Aktivität untersucht. Das MMR-Protein konnte durch Kultivierung von CHO-Zellen und Aufreinigung des Proteins aus dem Kulturmedium mittels Affinitätschromatographie isoliert werden.
-
Antibody-based biosensor assays for the detection of zilpaterol and markers for prostate cancer
… in a competitive ELISA format and on the Biacore (a surface plasmon resonance-based optical biosensor capable of monitoring biomolecular interactions in 'real-time'). A zilpaterol-HSA conjugate was used to generate and characterise single chain antibody fragments. A combinatorial single …
-
Microarray format for multi-parameter blood group serology
… detection system, we have exploited the Biacore system as a recognised platform for real-time interaction studies. Although this system is not designed for the high throughput applications needed in blood testing, in this study it provided detailed information on the interactions between …
-
Rapid methods for the detection of anti-protozoan drug residues.
… enzyme-linked immunosorbent assay (ELISA) and Biacore assay formats that were applied successfully for the detection of halofuginone in ‘spiked’ egg samples. Immune phage display libraries were constructed and screened for diclazuril using a number of diclazuril-conjugates. A functional …
-
The development and applications of polyclonal and monoclonal antibodies for the detection of illicit drugs in saliva samples
… The antibodies were applied to a biosensor (BIAcore) assay for the detection of amphetamine and methamphetamine in saliva samples. The affinity constants for the antibodies were determined by ELISA and BIAcore methods. The values obtained were found to be similar by both methods. A novel …
-
Novel anitbody-based assays for disease and food contaminant detection
… and subsequently used in an indirect ELISA and Biacore assay for the detection of antibodies to C. pseudotliberculosis in sheep serum samples. These assays were optimised using a variety of positive and negative controls and were then applied to a range of clinical samples from Irish herds. A …
-
Aptamers to the hepatitis C virus polymerase
… Ten rounds of selection were performed using a Biacore 2000 and resultant aptamers cloned from rounds 2, 4, 8 and 10. Sequences of aptamers were aligned to elucidate common motifs and a proportion of the aptamers from rounds 8 and 10 (29/48) were screened for binding ability using the Biacore. …
-
Using a biosensor platform for the detection and characterization of autoantibodies in myasthenia gravis patients
… a sensitive assay using a biosensor platform (Biacore™) for the measurement of these parameters in MG patients with MuSK antibodies. MuSK antigen was immobilized onto Biacore™ sensor chips and diluted sera injected over the surface to measure binding levels. Antibody isotype and subclass were …
-
Generation and application of recombinant antibody fragments for prostate cancer detection.
… kinetic analysis of candidate antibodies by Biacore. A differential expression profile of an anti-fPSA scFv and reformatted scAb was performed by ELISA. Individual antibodies isolated from the ‗biopanning‘ process were then characterised. The murine anti-fPSA antibodies were further analysed …
-
The production, characterisation and applications of polyclonal and monoclonal antibodies to warfarin
… for warfarin and also for the development of a BIACORE-based inhibition immunoassay. A panel of murine monoclonal antibodies to warfarin was also generated by somatic cell fusion procedures, using the spleens of mice, following in vivo immunisation with a variety of warfarin-protein conjugates. …
-
Untersuchungen zur Wirkungsweise von Zyklonukleotiden auf die Thrombozytenaktivierung
… als Wirkort der GMP-Analoga konnte in Biacore-Messungen ausgeschlossen werden. Es gilt nun, speziell den Thromboxanrezeptor auf mögliche Interaktionen mit GMP-Derivaten hin zu untersuchen.
-
Development of High Pressure Surface Plasmon Resonance for the Study of Biosystems
… available sensor chips. We have shown that BIAcore(TM) SA chips maintain their surface binding functionality after pressure exposure and that effects to the surface are reversible to 6000 psi. Three test systems were chosen to be studied using this instrument, each having different …
Page 1 of 4