Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 41 for “"Biaxial Testing"”.

  1. Biaxial testing device for large animal tissue experiments

    … as part of this research project is a planar biaxial testing device, which exerts opposing linear forces in two axes on a large animal tissue sample in the shape of a square. Improving upon the work of previous research, a new version is built at the Roy J. Carver Co-Laboratory at Iowa State …

    iastate Repository record for Biaxial testing device for large animal tissue experiments (opens in a new tab)

  2. Development of a Biaxial Testing System for Research of Soft Tissue Biomechanics using Laboratory Models

    … MPa). To this end, we developed a biomechanical testing system that allows us to characterize the material properties of small samples with high accuracy and precision. We built and validated the performance of the instrument’s subsystems (displacement, strain rate, gram-force readings, …

    cuny Repository record for Development of a Biaxial Testing System for Research of Soft Tissue Biomechanics using Laboratory Models (opens in a new tab)

  3. Establishment of biaxial testing system for characterization of small animal ventricle viscoelasticity under physiological loadings

    … The objective of this thesis is to establish a biaxial testing system that can characterize rodent ventricle viscoelasticity under physiological loadings. The new tester was validated using polydimethylsiloxane (PDMS) sheets. The results from the biaxial tester's viscoelastic measurement of PDMS …

    colostate Repository record for Establishment of biaxial testing system for characterization of small animal ventricle viscoelasticity under physiological loadings (opens in a new tab)

  4. Mechanical properties of arterial wall

    … on human arteries because of the difficulty of testing artery samples often obtained from autopsy while arteries are still considered "fresh". Various solutions mimicking the physiological environment have been used to preserve artery samples from harvesting to testing. In vitro mechanical …

    ubc Repository record for Mechanical properties of arterial wall (opens in a new tab) Download PDF for Mechanical properties of arterial wall (opens in a new tab)

  5. Biaxial Mechanical Testing of Native and Glycosaminoglycan-Depleted Porcine Aortic Wall

    … experiments: Experiment 1 (n=9) utilized planar biaxial testing to characterize arterial wall mechanics in native porcine aortas. The results of Experiment 1 highlight: (i) decreased tissue thickness moving distally, away from the heart; (ii) increased stiffness from the ascending aorta to the …

    ottawa-retro Repository record for Biaxial Mechanical Testing of Native and Glycosaminoglycan-Depleted Porcine Aortic Wall (opens in a new tab)

  6. Advancing the Extraction of Mechanical Properties from Biaxial Data

    … useful for donor tissue banks. Planar biaxial testing is one of the most common tools for the mechanical characterization of soft tissues. In this experiment, loadings such as displacements or forces are applied to the edges of the square specimens yielding deformations at the center of …

    waterloo Repository record for Advancing the Extraction of Mechanical Properties from Biaxial Data (opens in a new tab)

  7. Biaxial Quantification of Deep Layer Transverse Carpal Ligament Elastic Properties by Sex and Anatomical Region

    … work has been conducted investigating the biaxial elastic properties of the transverse carpal ligament (TCL), an important structure of the wrist with direct implications to carpal tunnel syndrome (CTS). Biaxial testing was conducted on human cadaveric TCL’s to assess differences in deep …

    guelph Repository record for Biaxial Quantification of Deep Layer Transverse Carpal Ligament Elastic Properties by Sex and Anatomical Region (opens in a new tab)

  8. Biomechanical Properties of the Transverse Carpal Ligament

    … to strain significantly more than the medial. Biaxial testing at three different tissue depths was also carried out. Mechanical properties were found to vary significantly by depth with the deeper layers displaying higher mechanical properties. A significant difference with respect to loading …

    guelph Repository record for Biomechanical Properties of the Transverse Carpal Ligament (opens in a new tab)

  9. A Structural and Functional Investigation of Reptilian Skin Using the Leopard Gecko (Eublepharis macularius)

    … and regenerated tail. We also used uniaxial and biaxial tensile testing to explore skin function. Overall, we determined that the vascularity and collagen architecture of regenerated skin is structurally equivalent to original skin. With uniaxial testing, we found that the tensile strength of …

    guelph Repository record for A Structural and Functional Investigation of Reptilian Skin Using the Leopard Gecko (Eublepharis macularius) (opens in a new tab)

  10. Experimental testing, image-based analysis, and finite element simulation of the tricuspid valve: towards personalized management of hypoplastic left heart syndrome

    … from three perspectives - in vitro experimental testing, in vivo image analysis, and in silico modeling. Starting with the in vitro studies, we build upon our previous biaxial mechanical characterization studies to provide a deeper understanding of the microstructure-mechanics relationships. In …

    oklahoma-thes Repository record for Experimental testing, image-based analysis, and finite element simulation of the tricuspid valve: towards personalized management of hypoplastic left heart syndrome (opens in a new tab) Restricted access

  11. Mechanical Behavior of Soft Materials (Skin/Rubber) under Cyclic Loading

    … it is helpful to study skin behavior under biaxial testing; a custom biaxial setup was built to study skin behavior under biaxial testing. Fiber orientations of undeformed and deformed samples are studied by histology. Fiber distribution shows that before deformation, fibers are randomly …

    tamu Repository record for Mechanical Behavior of Soft Materials (Skin/Rubber) under Cyclic Loading (opens in a new tab)

  12. Development of an experimental facility for biaxial compressive testing of fiber composite materials

    … purpose of this study was the development of a testing facility and test specimen for the characterization of laminated composites under biaxial compressive stress states. A biaxial testing facility capable of applying almost arbitrary stress paths in the in-plane compressive stress regime, to …

    texas Repository record for Development of an experimental facility for biaxial compressive testing of fiber composite materials (opens in a new tab) Restricted access

  13. Biomechanics of common carotid arteries from mice heterozygous for mgR, the most common mouse model of Marfan syndrome

    … model of Marfan syndrome, were studied in a biaxial testing device. Mechanical data in the form of pressure-diameter and force-stretch tests in both the active and passive states were collected, as well data on the functional responses to phenylephrine, carbamylcholine chloride, and sodium …

    tamu Repository record for Biomechanics of common carotid arteries from mice heterozygous for mgR, the most common mouse model of Marfan syndrome (opens in a new tab)

  14. Design of experiments for validation of multiaxial high cycle fatigue criteria

    … predictions differ are identified. Among them, biaxial stress states with high mid stresses are of special interest since such are often present in rotating engine components. Therefore, a testing method able to generate this state of stress is desirable. A literature review shows that the two …

    chalmers Repository record for Design of experiments for validation of multiaxial high cycle fatigue criteria (opens in a new tab)

  15. Fundamental and engineering application studies of pressure-assisted injection forging of thick-walled tubular components

    … tests was proposed, and particularly, a unique biaxial testing machine was developed and used satisfactorily. The test data were subsequently used to establish constitutive descriptions of the materials and to facilitate the FE modelling to simulate the forming processes. An upper bound analysis …

    strathclyde Repository record for Fundamental and engineering application studies of pressure-assisted injection forging of thick-walled tubular components (opens in a new tab)

  16. Computational construction and simulation of novel heart valve and vein valve designs

    … tissue grown in the lab, was developed based on biaxial testing and implemented in the FEM model. Fluid-structure interaction (FSI) simulation of the optimal design under steady flow was also conducted as a prelude to a next-stage optimization that includes valve dynamic performance metrics. The …

    umn Repository record for Computational construction and simulation of novel heart valve and vein valve designs (opens in a new tab)

  17. Mechanical characterization, modeling, and examination of a muscular intracranial and elastic extracranial artery with an emphasis on microstructure, residual stress, and smooth muscle cell activation

    … for a more microstructrually-based model. Biaxial testing was performed on acute basilar and carotid arteries and cultured basilar arteries. We used a validated 2D, four fiber family constitutive relation to model passive biaxial stress-stretch behaviors of basilar and common carotid …

    tamu Repository record for Mechanical characterization, modeling, and examination of a muscular intracranial and elastic extracranial artery with an emphasis on microstructure, residual stress, and smooth muscle cell activation (opens in a new tab)

  18. Biaxial Behavior of Ultra-High Performance Concrete and Untreated UHPC Waffle Slab Bridge Deck Design and Testing

    … challenges in mixing, placing, and curing UHPC. Biaxial testing was performed to evaluate behavior of UHPC in combined tension and compression stress states. A UHPC bridge deck was designed to perform similarly to a conventional concrete bridge deck, and a single unit bridge deck section was …

    vt Repository record for Biaxial Behavior of Ultra-High Performance Concrete and Untreated UHPC Waffle Slab Bridge Deck Design and Testing (opens in a new tab)

  19. Material and Process Models for the Forming of Oriented Polymer Tubes

    … properties of the tube. The uniaxial and biaxial testing of the OPP tubes enabled representation of the experimental plastic work contours for the material at a range of temperatures. The use of the pressure-modified Hill criterion, the concept of plastic work contours in stress space, and …

    mcmaster Repository record for Material and Process Models for the Forming of Oriented Polymer Tubes (opens in a new tab)

Page 1 of 3