Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"Bioaerosol sampling"”

  1. Design of bioaerosol sampling inlets

    … design, fabrication, and testing of an ambient sampling inlet and two additional Stokes-scaled inlets is presented here. Testing of each inlet was conducted at wind speeds of 2, 8, and 24 km/h (0.55, 2.22, and 6.67 m/s), and characterized for particle sizes between 5 and 20 µm AD. The …

    tamu Repository record for Design of bioaerosol sampling inlets (opens in a new tab)

  2. A study of bioaerosol sampling cyclones

    A wetted wall cyclone using an airblast atomizer upstream of the inlet was designed as an improvement of a wetted wall cyclone developed by White et al. in 1975, which uses liquid injection through a port on the wall of the cyclone inlet. In the course of this project, many changes to different …

    tamu Repository record for A study of bioaerosol sampling cyclones (opens in a new tab)

  3. An improved wetted-wall bioaerosol sampling cyclone

    … inlet. The new cyclone has a high aerosol sampling flow rate (1250 L/min) and maintains constant cut-point with the modified White-type cyclone along with greater collection efficiency, lower time response, and reduced pressure drop. The final air-blast atomizer cyclone (AAC2.1a) design …

    tamu Repository record for An improved wetted-wall bioaerosol sampling cyclone (opens in a new tab)

  4. Evaluation of a novel biosensor for bioaerosol sampling and modelling.

    The identification and quantification of bioaerosols in the atmosphere is a significant subject of study. Bioaerosols emitted from composting sites are released directly to the atmosphere, which can be potentially harmful to human health. Although there are several studies undertaken to improve the …

    cranfield Repository record for Evaluation of a novel biosensor for bioaerosol sampling and modelling. (opens in a new tab)

  5. Evaluation of Two Bioaerosol Sampling and Analysis Methods for the Collection of Airborne Bacteria and Viruses

    Bioaerosols, defined as airborne particles of biological origin, include bacteria, fungi, viruses, and their byproducts. They are ubiquitous in both indoor and outdoor environments and can cause respiratory infections, allergic reactions, and toxin-mediated illnesses. Air sampling plays a vital …

    unlv Repository record for Evaluation of Two Bioaerosol Sampling and Analysis Methods for the Collection of Airborne Bacteria and Viruses (opens in a new tab)

  6. Enhanced real-time bioaerosol detection : atmospheric dispersion modeling and characterization of a family of wetted-wall bioaerosol sampling cyclones

    … of biological weapons attacks through improved bioaerosol surveillance, detection, and response capabilities. The effects of bioaerosol release characteristics, transport in the atmospheric surface layer, and implications for bioaerosol sampler design and real-time detection were studied to …

    texas Repository record for Enhanced real-time bioaerosol detection : atmospheric dispersion modeling and characterization of a family of wetted-wall bioaerosol sampling cyclones (opens in a new tab)

  7. FILTER SAMPLING OF AIRBORNE MICROBIAL AGENTS - EVALUATION OF FILTER MATERIALS FOR PHYSICAL COLLECTION EFFICIENCY, EXTRACTION, AND COMPARISON TO TRADITIONAL BIOAEROSOL SAMPLING

    … the use of filter and other traditional sampling techniques for the collection of personal and area samples to evaluate microbial exposures. The first aim of this research was to determine filter materials and extraction methods appropriate for environmental sampling of Bacillus …

    ohiolink Repository record for FILTER SAMPLING OF AIRBORNE MICROBIAL AGENTS - EVALUATION OF FILTER MATERIALS FOR PHYSICAL COLLECTION EFFICIENCY, EXTRACTION, AND COMPARISON TO TRADITIONAL BIOAEROSOL SAMPLING (opens in a new tab)

  8. Molecular microbial ecology of Polar aerial environments

    … there is no consensus as to the most appropriate bioaerosol sampling method, and the degree to which sampling methodology impacts the results of bioaerosol studies is still unknown. This variability was assessed by testing the hypothesis that bacterial community profiles in Polar air samples are …

    northumbria Repository record for Molecular microbial ecology of Polar aerial environments (opens in a new tab)

  9. Ambient aerosol sampling inlet for flow rates of 100 and 400 l/min

    New bioaerosol sampling inlets were designed and tested that have nominal exhaust flow rates of 100 L/min to 400 L/min, and which have internal fractionators and screens to scalp large, unwanted particles and debris from the transmitted size distribution. These units consist of the same aspiration …

    tamu Repository record for Ambient aerosol sampling inlet for flow rates of 100 and 400 l/min (opens in a new tab)

  10. Low-cost fabrication methods for creating an inertial-based, multiphase microfluidic bioaerosol sampler

    … of an inertial-based, multiphase microfluidic bioaerosol sampling device. These desired parameters include optical transparency for visualizing flow conditions, uniform bond quality for a leak free device, good burst pressure capabilities due to high relative air pressures, and medium …

    iastate Repository record for Low-cost fabrication methods for creating an inertial-based, multiphase microfluidic bioaerosol sampler (opens in a new tab)

  11. Development of an optimized sampling regime for the determination of the effects of bioaerosols on health

    Bioaerosols vary in size between particle types which affects their airborne properties, influencing the type of sampler that can be used when trying to detect them. Despite this, there is no standardised protocol for measuring bioaerosols. Sampling experiments were performed in indoor environments …

    bedfordshire Repository record for Development of an optimized sampling regime for the determination of the effects of bioaerosols on health (opens in a new tab)

  12. Environmental Detection and Quantification of Airborne Influenza A Virus in an Elementary School, and its Implications for Student and Community Illness

    … were devised to (i) design and evaluate a bioaerosol sampling method to noninvasively detect influenza virus in the school environment, (ii) employ this noninvasive method to quantify airborne influenza virus densities to identify respiratory virus “hotspots” in a public elementary school, …

    ohiolink Repository record for Environmental Detection and Quantification of Airborne Influenza A Virus in an Elementary School, and its Implications for Student and Community Illness (opens in a new tab)

  13. Quantitative Bioprocess Containment Validation

    … ± 0.11 logs. This assay has been used to analyse bioaerosol samples collected by an Aerojet General Cyclone. Throughout the course of the project, work has been carried out to improve the collection efficiency of a cyclone sampler and to investigate the effects of various approaches to bioaerosol …

    ucl Repository record for Quantitative Bioprocess Containment Validation (opens in a new tab)

  14. Detecting and Comparing Bacteria in the Lower Airways of Children with Persistent Bacterial Bronchitis and a Healthy Population

    Lower airway sampling in paediatrics is challenging and often invasive. The role of infection in persistent bacterial bronchitis (PBB) is well established but there has been no microbiological comparison with PBB and a completely normal host. Bioaerosol sampling systems can non-invasively access …

    whiterose Repository record for Detecting and Comparing Bacteria in the Lower Airways of Children with Persistent Bacterial Bronchitis and a Healthy Population (opens in a new tab)

  15. Understanding and optimizing transport of aerosol particles in indoor environments and aerosol concentrators.

    … and in advancing methods to appropriately sample bioaerosols, which, while infectious, are in low concentration in the environment. The work in my dissertation is motivated by both developing bioaerosol sampling techniques for improved signal-to-noise ratios and limits of detection with biological …

    umn Repository record for Understanding and optimizing transport of aerosol particles in indoor environments and aerosol concentrators. (opens in a new tab)

  16. Degree of mixing downstream of rectangular bends and design of an inlet for ambient aerosol

    … with respect to suitability for single point sampling of contaminants. Several configurations, such as a straight duct with unidirectional flow at the entrance section and straight ducts preceded by mixing elements (a 90° mitred bend, double 90° bends in S- and U-type configurations) were …

    tamu Repository record for Degree of mixing downstream of rectangular bends and design of an inlet for ambient aerosol (opens in a new tab)

  17. QUANTITATIVE ESTIMATION OF ENTERIC PATHOGENS AND ANTIBIOTIC RESISTANCE GENES IN AEROSOLS NEAR URBAN WASTE FLOWS

    … pathogen transmission is prevalent. We deployed bioaerosol sampling strategies in three cities using coupled measurement of culturable fecal indicator bacteria (as an indirect proxy for viability) with multiplex quantitative PCR (qPCR) and droplet digital PCR (ddPCR) to estimate densities of …

    gatech Repository record for QUANTITATIVE ESTIMATION OF ENTERIC PATHOGENS AND ANTIBIOTIC RESISTANCE GENES IN AEROSOLS NEAR URBAN WASTE FLOWS (opens in a new tab)

  18. Characterisation of the air microbiome and its application in test and evaluation of biological detection equipment

    … transmission through biological aerosols (bioaerosols). Aerosolised biological threat (biothreat) agents can spread rapidly, affecting large populations while remaining difficult to detect, identify, and monitor. Existing equipment for detecting biothreat agents often struggles with …

    kings Repository record for Characterisation of the air microbiome and its application in test and evaluation of biological detection equipment (opens in a new tab)

  19. Characterising the Emission and Dispersion of Aerosols from the Toilet Plume and Quantification of the Associated Infection Risk

    … and returned to background levels within 10 min. Bioaerosol sampling using Escherichia coli showed that most bacteria were released in the first 5 min after flushing, with ventilation rates having a modest influence on airborne concentrations. Continuous but low-level bacterial deposition …

    whiterose Repository record for Characterising the Emission and Dispersion of Aerosols from the Toilet Plume and Quantification of the Associated Infection Risk (opens in a new tab)

  20. A field comparison of four bioaerosol samplers for enumerating airborne fungi

    … data. A field comparison of four bioaerosol samplers, the Reuter Centrifugal Sampler (RCS), the Andersen N6 Single Stage (N6), the Surface Air System Super 90, and the Air-o-Cell sampler (AOC), was conducted in a variety of public buildings for the measurement of fungal aerosols to …

    ubc Repository record for A field comparison of four bioaerosol samplers for enumerating airborne fungi (opens in a new tab)

Page 1 of 2