Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 333 for “"Biochemical oxygen demand"”

  1. ELECTROCHEMICAL MICROBIAL SENSOR FOR RAPID BIOCHEMICAL OXYGEN DEMAND MEASUREMENT

    A microbial sensor for rapid determination of biochemical oxygen demand of wastewaters was developed by coupling a dissolved oxygen probe with a biofilm, containing immobilized Bacillus subtilis and Bacillus licheniformis 7B, and a cross-linked poly(4-vinylpyridine) film. Both steady state and …

    nus Repository record for ELECTROCHEMICAL MICROBIAL SENSOR FOR RAPID BIOCHEMICAL OXYGEN DEMAND MEASUREMENT (opens in a new tab)

  2. Mediated biochemical oxygen demand biosensors for pulp mill wastewaters

    … and SPT2) were developed for the estimation of biochemical oxygen demand (BOD). Measurements of glucose/glutamic acid (GGA) standard solution with potassium ferricyanide mediation resulted in linear ranges extending from the detection limits (i.e. 2 and 5 ppm BOD) to 100 and 200 ppm BOD for the …

    mcgill Repository record for Mediated biochemical oxygen demand biosensors for pulp mill wastewaters (opens in a new tab)

  3. The effect of agitation on the biochemical oxygen demand sewage

    … to determine what effect agitation had upon the biochemical oxygen demand of sewage. In order to determine the effect of agitation, the composition of the sewage, the seed source, the temperature and the dilutions were held constant.

    vt Repository record for The effect of agitation on the biochemical oxygen demand sewage (opens in a new tab)

  4. Metal toxicities as measured by the biochemical oxygen demand test

    Thesis (M.S.)--Michigan State University of Agriculture and Applied Science. Dept. of Chemical Engineering, 1961

    msu Repository record for Metal toxicities as measured by the biochemical oxygen demand test (opens in a new tab)

  5. Correlation of Fluorescence Spectroscopy and Biochemical Oxygen Demand (BOD5) Using Regression Analysis

    … spectroscopy results to correlate with Biochemical Oxygen Demand (BOD5). Fluorescence spectroscopy was applied to samples taken from seven sample sites in the Provo and Orem waste water treatment plants found in Utah County. A total of 161 samples were collected for this research. 23 …

    byu Repository record for Correlation of Fluorescence Spectroscopy and Biochemical Oxygen Demand (BOD5) Using Regression Analysis (opens in a new tab)

  6. Correlation of biochemical oxygen demand with oxidation-reduction potential of settled sewage

    … exists between the O-R potential and the biochemical oxygen demand of settled sewage. The source of the samples was the effluent end of the primary clarifier at the V.P.I. Sewage Disposal Plant. The investigation consisted essentially of performing the standard biochemical oxygen demand …

    vt Repository record for Correlation of biochemical oxygen demand with oxidation-reduction potential of settled sewage (opens in a new tab)

  7. Manometric determination of the biochemical oxygen demand of sulfite paper mill wastes

    … determined by manometric measurement of the free oxygen utilized. In either case, the B.O.D. determination requires at least 24 hours. Since the free oxygen involved in the B.O.D. of a waste is utilized in metabolic processes of various microorganisms present, an increase in the number of …

    vt Repository record for Manometric determination of the biochemical oxygen demand of sulfite paper mill wastes (opens in a new tab)

  8. Statistical Evaluation of Rapid Biochemical Oxygen Demand Test for Monitoring Municipal Wastewater Quality

    … measuring wastewater quality include the 5-day biochemical oxygen demand (BOD5) and carbonaceous BOD (CBOD5). This thesis presents an alternative wastewater quality test that requires much less time to achieve valid results. This research addresses the precision and statistical validity of an …

    regina Repository record for Statistical Evaluation of Rapid Biochemical Oxygen Demand Test for Monitoring Municipal Wastewater Quality (opens in a new tab)

  9. Biochemical oxygen demand reduction of semi-chemical neutral sulfite waste by heat hydrolysis

    … (2) if pH, dilution and the addition of oxygen were factors that affected the reduction of B.O.D. These factors were determined by adjusting the raw liquor to the desired concentration and cooking the liquor in a closed container until certain conditions were obtained, namely, that of …

    vt Repository record for Biochemical oxygen demand reduction of semi-chemical neutral sulfite waste by heat hydrolysis (opens in a new tab)

  10. BIOSENSORS FOR SENSING ORGANIC SOLUTES AND BIOCHEMICAL OXYGEN DEMAND USING THERMALLY-KILLED MICROBIAL CELLS

    … to 280 °C for 2.5 minutes, was used for sensing biochemical oxygen demand (BOD) of organic solutes, waters and wastewaters. The BOD sensor was fabricated by covering a dissolved oxygen probe with a biofilm, containing the dead cells. The dead cell biosensor showed good sensing characteristics for …

    nus Repository record for BIOSENSORS FOR SENSING ORGANIC SOLUTES AND BIOCHEMICAL OXYGEN DEMAND USING THERMALLY-KILLED MICROBIAL CELLS (opens in a new tab)

  11. The Use of COD, TOC, Fluorescence, and Absorbance Spectroscopy to Estimate Biochemical Oxygen Demand in Wastewater

    … on organic matter, as determined by the five-day biochemical oxygen demand (BOD5) test. More rapid methods, such as chemical oxygen demand (COD), total organic carbon (TOC), fluorescence, and absorbance spectroscopy are also capable of quantifying organic matter. Previous studies indicate it is …

    unlv Repository record for The Use of COD, TOC, Fluorescence, and Absorbance Spectroscopy to Estimate Biochemical Oxygen Demand in Wastewater (opens in a new tab)

  12. A laboratory study of reduction of the biochemical oxygen demand of synthetic sewage by Zoogloea ramigera

    In order to improve the design and to control satisfactorily the operation of the modern sewage disposal and industrial waste treatment plants, a great deal of work remains to be done by competent sanitary engineers, biologists, and chemists. It is the general belief that the stabilization of …

    vt Repository record for A laboratory study of reduction of the biochemical oxygen demand of synthetic sewage by Zoogloea ramigera (opens in a new tab)

  13. A stochastic simulation study of the biochemical oxygen demand and dissolved oxygen in streams and estuaries

    Using Dobbins' deterministic equations Stochastic simulation was used to determine if, for K<sub>1</sub>, K<sub>2</sub> and K<sub>3</sub> randomized, the average BOD and DO would be close to its mean. The BOD and DO was determined by using the mean K values in Dobbins' equations. Similar …

    vt Repository record for A stochastic simulation study of the biochemical oxygen demand and dissolved oxygen in streams and estuaries (opens in a new tab)

  14. Application of the manometric technique to a study of the biochemical oxygen demand of a neutralized acid waste

    The purpose of this investigation was to use the manometric method to determine the effect of the following variables on the B.O.D. values of a neutralized acid industrial waste: pH, type of seed, age of seed, adapted seed, dilution water, and dilution. In order to determine the effect of each …

    vt Repository record for Application of the manometric technique to a study of the biochemical oxygen demand of a neutralized acid waste (opens in a new tab)

  15. Mathematical modeling and analytical solutions of dissolved oxygen and biochemical oxygen demand profiles under three-dimensional, unsteady-state conditions

    … temporal and spatial distribution of Dissolved Oxygen (DO) and Biochemical Oxygen Demand (BOD) for both pervious and impervious channel conditions in 3-dimensions have been constructed, and their analytical solutions were obtained. The solutions were implemented through the application of a …

    njit Repository record for Mathematical modeling and analytical solutions of dissolved oxygen and biochemical oxygen demand profiles under three-dimensional, unsteady-state conditions (opens in a new tab)

Page 1 of 17