Showing 1 to 20 of 107 for “"Biokinetic"”.
-
A generic biokinetic model for C-14 labelled compounds
… of its long half life of 5730 years. The current biokinetic model recommended by the International Commission on Radiological Protection (ICRP) is a conservative estimate of how radiocarbon is treated by the human body. The ICRP generic radiocarbon model consists of a single compartment …
-
A Bayesian approach to biokinetic models of internally deposited radionuclides
… developed and applied to estimate parameters of biokinetic models of internally deposited radionuclides for the first time. Marginal posterior densities for the parameters, given the available data, were obtained and graphed. These densities contain all the information available about the …
-
Coupling Hydrodynamic and Biokinetic Growth Models in Aerated Wastewater Treatment Processes
… thesis, a coupled hydrodynamic and wastewater biokinetic finite volume based CFD model for an aeration tank in OpenFOAM has been created to understand the effect of the hydrodynamics on the biological processes. A pilot-scale aeration tank that is aerated using fine membrane diffusers along the …
-
Mathematical solutions to problems in radiological protection involving air sampling and biokinetic modelling
… recycling models take a little longer. A biokinetic model for plutonium in man following systemic uptake was developed. The proposed ICRP lung model (1989) was represented by a first order compartmental model. These two models were combined, and the recycling algorithm was used to …
-
An investigation into the use of biokinetic models when assessing intakes of plutonium
… on some form of bioassay measurement used with a biokinetic model. There are many published biokinetic models that describe the transfer of radionuclides throughout the body. It would be beneficial at times if one could interchange certain biokinetic models with another to assess an intake based …
-
Bayesian estimation of biokinetic parameters for a two compartment model describing Calcium-45 exchange
… applied to obtain posterior densities of the biokinetic parameters of a two compartment model of Calcium-45 exchange between blood and bone surface with excretion.</p> <p>The mode of the posterior density for the blood to bone surface biokinetic parameter. estimates the rate of exchange to be …
-
Biokinetic behaviour of Chlorella vulgaris in a continuous stirred bioreactor and a novel circulating loop photobioreactor
… rate and mixing properties was used for the biokinetic study of C. vulgaris. The objective was to study individual effects of light intensity and CO2 concentration on the specific growth rate of C. vulgaris. Studies in this photobioreactor could generate high growth rates of 0.043 h-1. The …
-
Evaluation Of Prefermentation As A Unit Process Upon Biological Nutrient Removal Including Biokinetic And Wastewater Parameters
… benefits of primary clarification. Finally, some biokinetic parameters necessary to successfully model both the activated sludge systems and the prefermenter were determined and compared for the prefermented versus the non-prefermented system. Important findings developed during the course of this …
-
Evaluating the Risk to Ostomy Patients Working With Uranium Using the ICRP Biokinetic Model for the Gastrointestinal Tract
The ICRP has published two biokinetic models providing a basis for radiation dose assessment due toradionuclides incorporated inside the gastrointestinal tract. These models are a sufficient tool to assess the committed dose equivalent for occupational exposures to workers assuming normal anatomy. …
-
Bayesian Calibration of the ICRP Zirconium Biokinetic Model and Use of Canned Priors for the Evaluation of Bioassay
… on Radiological Protection (ICRP) publishes biokinetic models that relate measurements of radioactive material in the body and excreta (bioassay) to the amount of the material taken into the body (intake). Given the intake and the biokinetic model, radiation dose to organs and tissues can be …
-
Biokinetic Modeling and Dosimetry of Radiopharmaceutical Extravasation in Lu-177-PSMA Therapy for Metastatic Castration-Resistant Prostate Cancer
… with Lu-177‑PSMA therapy. A compartmental biokinetic model was constructed by appending an extravasation compartment to an established Lu-177‑PSMA framework, with transfer rates fitted from clinical literature. Using the Medical Internal Radiation Dosimetry (MIRD) formalism, the absorbed …
-
A Batch Biokinetic Study of the Preferential Separation of a Mixed Culture of Microorganisms Using Small-Size Hydrocyclones
… separation efficiency. </p> <p> The biokinetic aspects of this investigation are emphasized in this manuscript. </p>
-
Graphene-based wearable textile-triboelectric nanogenerators and biokinetic sensors [Nanogeneratori triboelettrici tessili indossabili a base di grafene e sensori biocinetici]
Questa tesi si concentra sullo sviluppo di nanogeneratori triboelettrici tessili a base di grafene (T-TENG) per la raccolta di energia indossabile e il rilevamento del movimento. È stato sviluppato un nuovo approccio per la sintesi di inchiostro di grafene tramite esfoliazione in fase liquida …
-
Using a Biokinetic Model to Quantify and Optimize Cortisol Measurements for Acute and Chronic Environmental Stress Exposure in Maternal and Child Health
… Therefore, we used R (v. 2.14.2) to create a biokinetic model of cortisol levels using parameters obtained from the published literature that relates cortisol concentrations among these compartments. Additionally, we can show overall elevation or depression of cortisol and changes in pulsatile …
-
Effects of nickel on activated sludge performance at varying COD:TKN ratios
… residence times, and COD removal efficiency, biokinetic coefficients, extent of nitrification, and nickel removal evaluated at each. Data from two earlier studies, in which 0.5 and 1 mg/l nickel doses were applied to similar units, were included for comparison. Organic removal efficiency was …
-
Biokinetic Modeling, Laboratory Examination And Field Analysis Of Dna, Rna And Protein As Robust Molecular Biomarkers Of Chloroethene Reductive Dechlorination In Dehalococcoides Mccartyi
… cultures and at a field site. A comprehensive biokinetic model of a community containing DMC strain 195 was updated to describe continuously fed reactors with specific biomass levels based on quantitative PCR (qPCR)-based population data (DNA and RNA). The model was calibrated and validated …
-
Degrading malonate waste in a membrane bioreactor : modeling and experiments
… of this research was to apply the standard biokinetic model used for conventional activated sludge to a MBR treating malonate, an organic acid contaminant found in industrial wastewater. Consequently, the biokinetic parameters synthesis yield coefficient (Y), endogenous decay coefficient …