Biomechanical Testing of Two-Level Cervical Disc Arthroplasty
In vitro biomechanical studies comparing two-level cervical disc arthroplasty with two-level fusion were completed using an established cadaveric cervical spine model. Three conditions were tested: non-instrumented, instrumented with two-level fusion (C5-C6 and C6-C7), and instrumented with …
-
Development and Biomechanical Testing of an Artificial Vertebral Body
… have been made with new devices that restore the biomechanical characteristics of the injured or degenerated human spine. Laboratory testing of implants is crucial for safety and efficacy, and one of the mainstays of testing remains the use of cadaver models for biomechanical analysis. Logistical …
-
Optimizing biomechanical testing of tissues by enhanced biaxial experimental capabilities
… critical tissue effects through experimental testing and database development. Key objectives include understanding pathological changes in diseased human tissue, defining a transfer function between fresh and formalin-fixed tissues, evaluating tissue changes due to ablation, and enhancing …
-
Biomechanical testing of an exercise for strengthening the proximal femur.
Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during …
-
Design, construction and validation of internal organ phantoms for biomechanical testing
… includes the development, construction and testing of internal organ phantoms, with focus on the liver, for biomechanical testing. Phantoms have various biomedical applications such as surgical simulations, minimally invasive surgery, soft tissue characterization, diagnostic tools and …
-
Biomechanical Testing on Cadaveric Spines for Different Treatments that Affect Lumbar Stability
… at 0.125Hz) and quasi-static (±7.5Nm at 0.1Hz) biomechanical tests, for flexion, extension, bending and rotation motions. Six FSUs where disarticulated from four human cadaveric lumbar spines (63 ± 12 years) and were tested under the following sequence: (1) intact, (2) laminectomy decompression, …
-
Development and validation of a surrogate ankle for biomechanical testing of footwear
… of footwear were determined using a multi-axis testing apparatus and evaluated at different lace tensions for multiple motions. The surrogate can be used in future studies to investigate footwear design that may potentially mitigate ankle injury."--Page ii.
-
Biomechanical testing of upright range of motion versus overhead supine range of motion
Rehabilitation of an elbow, following injury, is not a well-studied subject. Clinically, there is not a general consensus on which recovery method is optimal for healing an unstable elbow. When dealing with medial collateral ligament deficiency, many authors have proposed several forearm positions …
-
A study of a Gough-Stewart platform-based manipulator for applications in biomechanical testing.
… and application of a robotic system for in-vitro biomechanical testing to study the mechanisms leading to human joint injury and degeneration in an ethical and safe manner. Six degree of freedom (6-DOF) robotic-based systems, in particular Gough-Stewart platform-based systems, have been …
-
Investigation of Toe Tip Necrosis Syndrome in Feedlot Cattle using Biomechanical Testing and Imaging
… ten healthy specimens were loaded in a materials testing system against an acrylic plate. A camera, located underneath the hoof, imaged the apical region to identify the area of white line separation. Specimens were imaged using a High-Resolution Peripheral Quantitative Computed Tomography …
-
The Development and Application of a Custom Robotic Biomechanical Testing Platform Employing Real-time Load-control to Compare Spinal Biomechanical Testing Protocols: Pure Moment, Ideal Follower Load, and a Novel Trunk Weight Protocol
The human lumbar spine has been the subject of biomechanical study for many decades owing to the numerous medical cases resulting in the development of various corrective surgical procedures and medical devices intended to relieve patient discomfort. Spinal biomechanics is a broad field containing …
-
Biomechanical Testing of Salter-Harris Fractures Type I and II in the Distal Femur and Proximal Tibia
… The purpose of this study is to analyze the biomechanical efficacy of common fixation methods used to stabilize Salter-Harris I and II fracture patterns in both the proximal tibia and distal femur. Rotational stiffness will be used as the primary gauge of efficacy and is tested in flexion and …
-
Computer controlled device to independently control flow waveform parameters during organ culture and biomechanical testing of mouse carotid arteries.
Understanding the mechanisms of cardiovascular disease progression is essential in developing novel therapies to combat this disease that contributes to 1 in 3 deaths in the United States every year. Endothelial dysfunction and its effects on vessel growth and remodeling are key factors in the …
-
Ex Vivo Biomechanical Testing to Examine the Etiology of Low Back Pain as a Result of Whole Body Vibration
… studies. However, the etiological and biomechanical mechanisms of how WBV contributes to LBP and injury are not well understood. Using field-measured occupational WBV exposures in a controlled laboratory setting, this study attempted to expose the human lumbar spine to occupational WBV …
-
Use of a Spine Robot Employing a Real Time Force Control Algorithm to Develop, Simulate, and Compare Spinal Biomechanical Testing Protocols: Eccentric Loading, Pure Moment, and a Novel Head Weight Protocol
In vitro testing provides a critical tool for understanding the biomechanics of the subaxial cervical spine. Previous common testing protocols used to evaluate the subaxial cervical spine include Pure Moment (PM), follower load, and eccentric lever arm (EL) loading methods. Although these methods …
-
Design and Development of Mechanical Testing Systems for Applications in Bone Biomechanics Evaluation: Bone Damage Repair and Classification
Mechanical testing is essential for determining and understanding material characteristics. When engineers develop a product based on their material knowledge, they can analyze the validity and reliability of the final product and, as a result, assure its safety. The mechanical testing …
-
Examination of a new arthrodesis technique for equine cervical vertebrae
… the findings from a single case. 2. Examine the biomechanical properties of the construct in cadaver specimens and compare the biomechanical properties with the currently used arthrodesis technique. Study design – Case report, followed by two in vitro biomechanical investigations. Sample …