Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 50 for “"Biomedical Implant"”

  1. Microwave Assisted Calcium Phosphate Coating of Biomedical Implant Materials

    … of using a novel coating method to coat the biomedical implant materials polyether ether ketone (PEEK) and nitinol. In the field of orthopedics, many promising implant materials cannot easily bond directly to the surrounding bone. PEEK is a polymer which exhibits favorable mechanical …

    ohiolink Repository record for Microwave Assisted Calcium Phosphate Coating of Biomedical Implant Materials (opens in a new tab)

  2. Metal-Protein Interactions of Relevance for Biomedical Implant Corrosion

    … but also directly through medical interventions. Biomedical implants, such as hip and knee prostheses, are constructed from metal alloys that corrode and degrade over time, releasing metal ions and metal nanoparticles (NPs) into the surrounding tissues and fluids. These degradation products …

    uwo Repository record for Metal-Protein Interactions of Relevance for Biomedical Implant Corrosion (opens in a new tab)

  3. Numerical optimisation of biomedical implant characteristics for increased service life.

    … optimisation technique with the aim to decrease implant stress shielding which in turn could increase Total Hip Arthroplasty (THA) service life and reduce patient discomfort by employing a distributed stiffness along implant length. Research found that through distributing stiffness along THA …

    adelaide Repository record for Numerical optimisation of biomedical implant characteristics for increased service life. (opens in a new tab)

  4. COMPOSITION – PROCESSING – MICROSTRUCTURE – PROPERTY RELATIONSHIPS OF THE ZINC-MAGNESIUM SYSTEM FOR ABSORBABLE BIOMEDICAL IMPLANT APPLICATIONS

    … as the next generation of temporary medical implants by safely dissolving in the human body upon vascular tissue healing and bone regeneration. Their incorporation in the market could greatly reduce the need and risks associated with additional surgeries and other complications often related …

    msu Repository record for COMPOSITION – PROCESSING – MICROSTRUCTURE – PROPERTY RELATIONSHIPS OF THE ZINC-MAGNESIUM SYSTEM FOR ABSORBABLE BIOMEDICAL IMPLANT APPLICATIONS (opens in a new tab)

  5. Design of Voltage Boosting Rectifiers for Wireless Power Transfer Systems

    … rectifier for wireless power transfer in biomedical implant systems. The rectifier is built using Schottky diodes. The design has been simulated in 0.5µm and 130nm CMOS processes. The challenges for a rectifier in a wireless power transfer systems are observed to be the efficiency, output …

    unt Repository record for Design of Voltage Boosting Rectifiers for Wireless Power Transfer Systems (opens in a new tab)

  6. Bioactivity and Structural Properties of Hydroxyapatite on Ti6A|4V and Si(100) Surfaces by Pulsed Laser Deposition

    Although biomedical implant technology is very advanced, there are still caveats in terms of biocompatibility properties because metals are inert to biological processes such as osseointegration, cell growth, and cell adhesion. This results in statistically significant complications and opens rooms …

    wku-diss Repository record for Bioactivity and Structural Properties of Hydroxyapatite on Ti6A|4V and Si(100) Surfaces by Pulsed Laser Deposition (opens in a new tab)

  7. Electron energy loss spectroscopy and bioapplications of silicon nanowires

    … applications in electronics, photovoltaics and biomedical applications, but as of yet, silicon nanowires are not used in any commercial application. More characterization is needed to better understand and control their surfaces and electronic properties. Here, electron energy loss spectroscopy …

    texas Repository record for Electron energy loss spectroscopy and bioapplications of silicon nanowires (opens in a new tab)

  8. Mechanism of Biocorrosion Caused by Biofilms and Its Mitigation

    … oil and gas industry, water utilities, and the biomedical implant industry. MIC can cause severe corrosion of medical devices. To minimize the effect of MIC, in this study, the mechanisms of MIC and a novel antimicrobial Cu-bearing stainless steel were investigated. For the mechanistic study, …

    ohiolink Repository record for Mechanism of Biocorrosion Caused by Biofilms and Its Mitigation (opens in a new tab)

  9. Cell Adhesion on Synthetic Polymer Substrates

    … relevance of cell culture to the assessment of biomedical implant materials is discussed.

    aston Repository record for Cell Adhesion on Synthetic Polymer Substrates (opens in a new tab)

  10. Scalable machining of micro-features for orthopedic and tribological applications

    … in various industrial sectors, including the biomedical and tribological communities. While numerous manufacturing methods are available for the fabrication of these micro-features, advancements in high-precision machinery and piezoelectric actuation have allowed for the development of new and …

    gatech Repository record for Scalable machining of micro-features for orthopedic and tribological applications (opens in a new tab)

  11. Multiscale Modeling and Analysis of Biomedically Relevant UHMWPE-based Composite Materials

    … to present significant opportunities in biomedical engineering, particularly in joint arthroplasty and implant technologies. As applications expand, the need for accurate modeling of microstructure–property relationships to guide informed material design and manufacturing decisions is …

    unh-thes Repository record for Multiscale Modeling and Analysis of Biomedically Relevant UHMWPE-based Composite Materials (opens in a new tab)

  12. Integrated Electromagnetic Wireless Power Harvesting System for mm-size Biomedical Implants

    … recent years has resulted in the development of implantable biopotential sensors. Infection risks and mobility concerns constrain the implanted sensors to operate without any transcutaneous wire connection which raises serious challenges for powering and data telemetry. Lack of enough information …

    rice Repository record for Integrated Electromagnetic Wireless Power Harvesting System for mm-size Biomedical Implants (opens in a new tab)

  13. The effects of calcification on the structure and properties of biomedical polyurethanes

    … has been shown to cause premature failure of biomedical implant devices in several clinical cases. Although several mechanistic theories exist regarding the causes of calcification, it was necessary to consider the nature of the interaction of the calcium salts with the implant material to …

    utk-theses Repository record for The effects of calcification on the structure and properties of biomedical polyurethanes (opens in a new tab)

  14. Characteristics of Porous Ti-6Al-4V Implant Fabricated by Electron Beam Melting (EBM) for Biomedical Applications

    … system demands specific features for the implant materials for rejuvenation of lost body functions. The porous network have significant contributions towards biomechanical rejuvenation of the musculoskeletal system. The bone tissue – implant material interaction possess significant …

    chalmers Repository record for Characteristics of Porous Ti-6Al-4V Implant Fabricated by Electron Beam Melting (EBM) for Biomedical Applications (opens in a new tab)

  15. Surface morphology investigation of a biodegradable magnesium alloy

    … properties of Mg alloy discs as samples of biomedical implants prepared using powder forming technology were investigated. The main motivation of this study was to achieve the manufacturing of porous and micro-surface textured Mg-based biomedical implants with good mechanical and …

    metu Repository record for Surface morphology investigation of a biodegradable magnesium alloy (opens in a new tab)

  16. Battery-less Transmitter and Frequency-Agile Receiver for IoT Applications

    … demands for IoT device, wearable device and biomedical implants have been calling for more low power, energy efficient and highly integrated devices from electronic industry. Implementing transmitter and energy-harvesting circuits on a same chip is a good way to provide battery-less systems …

    rice Repository record for Battery-less Transmitter and Frequency-Agile Receiver for IoT Applications (opens in a new tab)

  17. Wear behavior of Ti-6Al-4V for Joint Implants manufactured by Electron Beam Melting

    … bed-based EBM technology has been utilized for biomedical implant manufacturing. Anisotropic microstructure of the EBM built implant surface is closelyrelated to wear and corrosion behavior during active biomechanical loadings. A series of experimental studies are performed in ambient and in …

    ohiolink Repository record for Wear behavior of Ti-6Al-4V for Joint Implants manufactured by Electron Beam Melting (opens in a new tab)

  18. Corrosion behavior of microarc oxidation and polycaprolactone coatings applied to AZ31 magnesium alloy evaluated in simulated body fluid and balanced salt solution

    Recent research in orthopedic implant materials has focused on the use of magnesium alloys as a base material due to its mechanical properties similar to that of human bone. Rapid corrosion of magnesium materials in aqueous environments poses a significant hurdle to their application as a …

    alaska Repository record for Corrosion behavior of microarc oxidation and polycaprolactone coatings applied to AZ31 magnesium alloy evaluated in simulated body fluid and balanced salt solution (opens in a new tab)

Page 1 of 3