Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 23 for “"Biomedical Ultrasound"”

  1. Gradient-driven and reduced-rate beamforming for biomedical ultrasound

    … can significantly improve the image quality in biomedical ultrasound by reducing the clutter due to interfering signals arriving from undesired directions. Adaptive beamforming is computationally expensive, and the objective of this thesis is to expose and explore tradeoffs between computational …

    uvic Repository record for Gradient-driven and reduced-rate beamforming for biomedical ultrasound (opens in a new tab)

  2. Novel Techniques for Tissue Imaging and Characterization Using Biomedical Ultrasound

    The use of ultrasound technology in the biomedical field has been widely increased in recent decades. Ultrasound modalities are considered more safe and cost effective than others that use ionizing radiation. Moreover, the use of high-frequency ultrasound provides means of high-resolution and …

    wvu Repository record for Novel Techniques for Tissue Imaging and Characterization Using Biomedical Ultrasound (opens in a new tab)

  3. A comparative evaluation of two Synthetic Transmit Aperture with Virtual Source beamforming methods in biomedical ultrasound

    … method, which is an emerging technique in biomedical ultrasound. It promises better imaging quality compared to conventional beamforming, with the same imaging speed. Several specific realizations of the STA-VS methods have been proposed in the literature and the topic is an active research …

    ubc Repository record for A comparative evaluation of two Synthetic Transmit Aperture with Virtual Source beamforming methods in biomedical ultrasound (opens in a new tab)

  4. Improved characterisation and modelling of microbubbles in biomedical applications

    … and quantitative imaging applications in biomedical ultrasound has increased the need for their accurate modelling. However, effects such as gas diffusion, the properties of the coating and changes in bubble behaviour under repeated ultrasound pulses are still poorly understood. The work …

    ucl Repository record for Improved characterisation and modelling of microbubbles in biomedical applications (opens in a new tab)

  5. Three dimensional acoustic microbubble dynamics near rigid boundary

    … of cavitation microbubbles due to high intensity ultrasound are associated with important applications in biomedical ultrasound, ultrasonic cleaning and sonochemistry. Previous numerical studies on this phenomenon were for an axisymmetric configuration. In this thesis, a computational model is …

    birmingham Repository record for Three dimensional acoustic microbubble dynamics near rigid boundary (opens in a new tab)

  6. Tissue Bioeffects during Ultrasound-Mediated Drug Delivery

    Ultrasound has been developed as both a valuable diagnostic tool and a potent promoter of beneficial tissue bioeffects for the treatment of cardiovascular disease. Vascular effects can be mediated by mechanical oscillations of circulating microbubbles, or ultrasound contrast agents, which may also …

    ohiolink Repository record for Tissue Bioeffects during Ultrasound-Mediated Drug Delivery (opens in a new tab)

  7. Fabrication and characterisation of novel ultrasound transducers

    … are in demand to improve spatial resolution for biomedical ultrasound imaging applications. However, increasing the operational frequency of these materials is extremely challenging as ultrafine dimensions are required in conventional composite designs. An innovative randomised composite design …

    birmingham Repository record for Fabrication and characterisation of novel ultrasound transducers (opens in a new tab)

  8. Bubble dynamics and its application in dental cleaning

    … propeller damage. Acoustic cavitation also has biomedical ultrasound, sonochemistry, and cavitation cleaning applications. This thesis includes three published journal articles concerned with the dynamics of a single bubble in a viscous compressible liquid near a rigid boundary at a moderately …

    birmingham Repository record for Bubble dynamics and its application in dental cleaning (opens in a new tab)

  9. Numerical Investigation of Ultrasound-Triggered Microbubble Contrast Agent Dynamics

    Biomedical ultrasound is widely employed as an imaging modality for anatomical assessment and to provide information on blood flow characteristics. There is increasing interest in employing microbubble contrast agents for diagnostic and therapeutic ultrasound. Unlike MR and CT agents, ultrasound …

    concordia

  10. MEMS GHz Sonar for Through Silicon Communications and Sensing Applications

    … CMOS compatible fingerprint sensor. The use of ultrasound allows for numerous advantages over current capacitive and optical fingerprint sensors, including higher penetration through glass and metal layers, as well as enhancing the spoof resistance of the fingerprint sensor by allowing the …

    cornell Repository record for MEMS GHz Sonar for Through Silicon Communications and Sensing Applications (opens in a new tab)

  11. Engineering Ultrasound Contrast Agents for Increased Stability and Nonlinearity

    … diagnostic and therapeutic applications of biomedical ultrasound. New techniques have been developed which rely upon nonlinear scattering of acoustic waves by contrast agents undergoing volumetric oscillations upon exposure to ultrasound. The degree of nonlinearity can be improved by …

    ucl Repository record for Engineering Ultrasound Contrast Agents for Increased Stability and Nonlinearity (opens in a new tab)

  12. Evaluation of hybrid GSC-based and ASSB-based beamforming methods applied to ultrasound imaging

    The application of adaptive beamforming to biomedical ultrasound imaging has been an active research area in recent years. Adaptive beamforming techniques have the capability of achieving excellent resolution and sidelobe suppression, thus improving the quality of the ultrasound images. This …

    uvic Repository record for Evaluation of hybrid GSC-based and ASSB-based beamforming methods applied to ultrasound imaging (opens in a new tab)

  13. Superharmonic Contrast Imaging with Dual-Frequency Technology for Tumor Vasculature Visualization

    … to control both arrays using programmable ultrasound systems to allow beamforming with electronic delays to manipulate beam shapes. We then characterized the acoustic performance of this integrated probe and demonstrated its capability of SpHI with conventional line-by-line imaging in vitro …

    toronto-retro Repository record for Superharmonic Contrast Imaging with Dual-Frequency Technology for Tumor Vasculature Visualization (opens in a new tab)

  14. Computation Of Acoustic Ressure Fields Produced In Feline Brain By High-Intensity Focused Ultrasound

    In 1975, Dunn et al. (Jasa 58:512-514) shothat a simple relation describes the ultrasonic threshold for cavitation induced changes in the mammalian brain. The thresholds for tissue damage were estimated for a variety of acoustic parameters in exposed feline brain. The goal of this study was to …

    mississippi Repository record for Computation Of Acoustic Ressure Fields Produced In Feline Brain By High-Intensity Focused Ultrasound (opens in a new tab)

  15. Dynamics of Multi-functional Acoustic Holograms in Contactless Ultrasonic Energy Transfer Systems

    … can generate arbitrary and pre-designed ultrasound fields in a particular distance from the hologram mounted on the transmitter, i.e., a target plane. This dissertation presents the use of these simple, cost-effective, and high-fidelity acoustic holograms in UPT systems to selectively …

    vt Repository record for Dynamics of Multi-functional Acoustic Holograms in Contactless Ultrasonic Energy Transfer Systems (opens in a new tab)

  16. Frequency smoothed robust Capon beamformer applied to medical ultrasound imaging

    … array beamforming has been applied to medical ultrasound imaging and achieved promising performance improvement. However, the current robust Capon beamformer with spatial smoothing (RCB-SS) is implemented in the time domain, which does not fully utilise the large bandwidth of ultrasound signals …

    anu Repository record for Frequency smoothed robust Capon beamformer applied to medical ultrasound imaging (opens in a new tab)

  17. NOVOS TRANSDUTORES PIEZOFOTÓNICOS PARA APLICAÇÕES BIOMÉDICAS.

    In recent years, photoacoustic transducers have rapidly evolved, standing out for their ability to generate high-amplitude, broadband ultrasonic pulses in flexible, miniaturizable configurations fully compatible with optical systems. These features make them promising not only for high-resolution …

    coimbro Repository record for NOVOS TRANSDUTORES PIEZOFOTÓNICOS PARA APLICAÇÕES BIOMÉDICAS. (opens in a new tab)

  18. Acoustic Holograms for Hyperthermia and Transcranial Ultrasound

    [ES] Los ultrasonidos se han empleado desde los años 90 para el tratamiento de múltiples patologías gracias a su carácter no invasivo y no ionizante, desde el tratamiento localizado del cáncer hasta terapias neurológicas. La focalización de estas ondas de presión y la conformación del haz ha sido …

    upv Repository record for Acoustic Holograms for Hyperthermia and Transcranial Ultrasound (opens in a new tab)

  19. Multiparametric functional ultrasound imaging : from fundamental neuroscience to translation neuroimaging

    Les progrès de la neuroimagerie ont continuellement renouvelé notre compréhension du cerveau, en améliorant sans cesse les résolutions spatiale et temporelle; pourtant, certains régimes et phénomènes restent difficiles à caractériser quantitativement. D’une part, le cerveau endormi constitue un …

    star-france Repository record for Multiparametric functional ultrasound imaging : from fundamental neuroscience to translation neuroimaging (opens in a new tab)

  20. Imagerie 3D ultrasonore de la microcirculation : application à l’imagerie 3D des flux coronariens

    La microcirculation des flux sanguins repose sur un réseau vasculaire complexe composé de vaisseaux de quelques microns à 300µm de diamètre. Elle permet d’adapter les flux sanguins à la demande d’oxygène. Aujourd’hui, ce compartiment vasculaire ne peut pas être imagé avec une résolution suffisante …

    star-france Repository record for Imagerie 3D ultrasonore de la microcirculation : application à l’imagerie 3D des flux coronariens (opens in a new tab)

Page 1 of 2