Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 143 for “"Biomedical implants"”.

  1. WIRELESS POWER TRANSFER TO BIOMEDICAL IMPLANTS

    … found their use in a plethora of applications, biomedical implants being one of them. The stringent regulation on size and safety imposed by the biomedical implants necessitates a highly efficient power transfer link design. The added challenges of misalignment and motion artifact very common in …

    nus Repository record for WIRELESS POWER TRANSFER TO BIOMEDICAL IMPLANTS (opens in a new tab) Download file for WIRELESS POWER TRANSFER TO BIOMEDICAL IMPLANTS (opens in a new tab)

  2. Wireless Power for Miniaturised Biomedical Implants

    … is increasing pressure to reduce the size of implants as this makes their deployment easier and less invasive (such as delivery through the venous network). The purpose of this thesis is to design and develop an effective method of powering small, deeply implanted devices. An alternative to …

    auckland-ms Repository record for Wireless Power for Miniaturised Biomedical Implants (opens in a new tab)

  3. Synthesis of Ag-DLC coatings for biomedical implants

    … direct current (DC) magnetron sputtering for biomedical implants. The silver concentration was varied in the DLC matrix by varying the DC power to the silver target from 12 W to 18 W. Raman spectroscopy was carried out to evaluate the structural changes in the carbon matrix. X-ray …

    sask Repository record for Synthesis of Ag-DLC coatings for biomedical implants (opens in a new tab)

  4. Next generation RFID telemetry design for biomedical implants.

    The design and development of a Radio Frequency Identification (RFID) based pressure-sensing system to increase the range of current Intra-Ocular Pressure (IOP) sensing systems is described in this dissertation. A large number of current systems use near-field inductive coupling for the transfer of …

    louisville Repository record for Next generation RFID telemetry design for biomedical implants. (opens in a new tab)

  5. Power efficient current recycling linear regulators for biomedical implants

    … scaling in size of the electrodes in the modern biomedical implants, high-voltage power supplies (some 5-20V) are necessitated for electrodes actuation purposes while most the implantable electronic sub-systems are operating under low-voltage power supplies (3V) generated by linear regulators …

    unsw Repository record for Power efficient current recycling linear regulators for biomedical implants (opens in a new tab)

  6. Near-field baseband communication system for use in biomedical implants

    … baseband pulse radio communication for biomedical implants. It details the design and implementation of the complete communication system with a particular emphasis on the antenna structure and waveform coding that is compatible with this particular technology. The wireless communication …

    glasgow Download PDF for Near-field baseband communication system for use in biomedical implants (opens in a new tab)

  7. Energy-efficient and miniaturized radio frequency systems for biomedical implants

    … promise tremendous progress in the field of biomedical technology: They can be applied to investigate and even suppress neural diseases, allow to bridge damaged peripheral nerves to reestablish motion and enable robotic assistance devices to be controlled by pure imagination. <br>The …

    freiburg-diss Repository record for Energy-efficient and miniaturized radio frequency systems for biomedical implants (opens in a new tab)

  8. DESIGN, MANUFACTURING, AND CHARACTERIZATION OF ELASTOMERIC DEVICES FOR BIOMEDICAL IMPLANTS

    … proven effective for load bearing structural implants, for addressing craniomaxillofacial reconstruction, and airway obstructions. To date, however, there are no clinical examples of additively manufactured soft devices. In this thesis, I will present an approach for the rapid prototyping of a …

    cornell Repository record for DESIGN, MANUFACTURING, AND CHARACTERIZATION OF ELASTOMERIC DEVICES FOR BIOMEDICAL IMPLANTS (opens in a new tab)

  9. Ultra-low-power event-driven radio system for miniaturized biomedical implants

    … medical devices (IMDs) such as cochlear implants, capsule endoscopy, brain-machine interface, and smart stents, telemonitoring and wireless communication are key functions. The radio-frequency (RF) communication systems for IMDs differ from conventional data-driven radios in various …

    ubc Repository record for Ultra-low-power event-driven radio system for miniaturized biomedical implants (opens in a new tab) Download PDF for Ultra-low-power event-driven radio system for miniaturized biomedical implants (opens in a new tab)

  10. Integrated Electromagnetic Wireless Power Harvesting System for mm-size Biomedical Implants

    … and can be exploited to power up ultra-low power biomedical implants. The second system is designed to increase the functionality of a complex implant such as a neural recording system. While maintaining the losses in biological tissues below Specific Absorption Rate (SAR) limit, the harvesting …

    rice Repository record for Integrated Electromagnetic Wireless Power Harvesting System for mm-size Biomedical Implants (opens in a new tab)

  11. Development of hybrid robotic-assisted technology for multifunctional biomedical implants customization

    … when producing complex, micro-scale, and biomedical components. By combining laser-based additive manufacturing (AM) with multi-axis CNC subtractive machining (SM), the system allows for the precise customization of intricate geometries and surface characteristics. A key innovation of this …

    minho-thes Repository record for Development of hybrid robotic-assisted technology for multifunctional biomedical implants customization (opens in a new tab)

  12. Materials Processing Towards Development of Rapid Prototyping Technology for Manufacturing Biomedical Implants

    Sintering of gel-cast calcium hydroxyapatite was studied by means of thermal analysis, XRD, mechanical testing, and SEM, both for sub-micron and the agglomerated powder type. Transformation temperatures of tri-calcium phosphate upon cooling were determined as 1475&deg;C for (alpha' to alpha, …

    uiuc Repository record for Materials Processing Towards Development of Rapid Prototyping Technology for Manufacturing Biomedical Implants (opens in a new tab)

  13. A Novel Control Scheme for Class E Wireless Power Transfer Systems in Biomedical Implants

    Active biomedical implants offer the potential to improve the quality of life for patients suffering from medical conditions such as total heart failure, retinitis pigmentosa, and age-related macular degeneration, which are typically incurable or require extensive surgical intervention. Wireless …

    queens Repository record for A Novel Control Scheme for Class E Wireless Power Transfer Systems in Biomedical Implants (opens in a new tab)

  14. Novel biodegradable polymeric and composite structures to be used as biomedical implants and tissue engineering scaffolds

    … and hence control the mechanical properties. For biomedical applications, the mismatch between the mechanical properties of a device made out of biodegradable polymer and the tissue intended to be regenerated may compromise the clinical success of the tissue engineering construct. The processing – …

    minho-thes Repository record for Novel biodegradable polymeric and composite structures to be used as biomedical implants and tissue engineering scaffolds (opens in a new tab)

  15. Onset of fretting corrosion in biomedical implants: surface roughness evolution under contact loads and corrosive environment

    <p>Fretting corrosion of orthopedic implants leads to surface failures that induce a cascade of biocompatibility problem like inflammation and even osteolysis. At the interfaces of modular implant components femoral head-neck taper connection, surfaces are subjected to cyclic contact loadings and …

    iastate Repository record for Onset of fretting corrosion in biomedical implants: surface roughness evolution under contact loads and corrosive environment (opens in a new tab)

  16. Design, fabrication and characterization of a double-network alginate-pHEMA hydrogel coating for PDMS-based biomedical implants

    Traditional silicone biomedical implants, such as urinary catheters, often suffer from high surface friction, high stiffness, and a lack of hydrophilicity, which can cause discomfort or discomfort. To tackle these challenges, we developed a double-network alginate-pHEMA hydrogel “cushion” coating …

    ubc Repository record for Design, fabrication and characterization of a double-network alginate-pHEMA hydrogel coating for PDMS-based biomedical implants (opens in a new tab) Download PDF for Design, fabrication and characterization of a double-network alginate-pHEMA hydrogel coating for PDMS-based biomedical implants (opens in a new tab)

  17. Influence of Cerium on the Mechanical and Corrosion Properties of Mg-Zn-Ca Alloys for Biomedical Implants

    Temporary orthopedic implants require alloys with high biocompatibility, mechanical strength, and controlled degradation. Magnesium alloys with 1 and 4 wt.% zinc, 0.25 wt.% calcium, and 0.1, 0.2, and 0.5 wt.% cerium were cast and characterized using compression, microhardness, x-ray diffraction, …

    guelph Repository record for Influence of Cerium on the Mechanical and Corrosion Properties of Mg-Zn-Ca Alloys for Biomedical Implants (opens in a new tab)

Page 1 of 8