Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Biomedical instrumentation"”.

  1. The development of biomedical instrumentation using backscattered laser light

    This thesis is concerned with the measurement of blood flow and oxygen saturation in the microcirculation using the techniques of laser Doppler flowmetry and pulse oximetry. An investigation of the responses of Doppler flowmeters using different signal processing bandwidths and laser sources …

    oxford-brookes Repository record for The development of biomedical instrumentation using backscattered laser light (opens in a new tab) Download PDF for The development of biomedical instrumentation using backscattered laser light (opens in a new tab)

  2. Biomedical instrumentation and nanotechnology for image-guided cancer surgery

    … radiation therapy. Here, we describe a prototype instrumentation system that can provide intraoperative guidance with exogenous optical contrast agents. The instrumentation combines interactive point excitation, local spectroscopy, and widefield fluorescence imaging to enable low-cost surgical …

    gatech Repository record for Biomedical instrumentation and nanotechnology for image-guided cancer surgery (opens in a new tab)

  3. Increasing Signal to Noise Ratio and Minimising Artefacts in Biomedical Instrumentation Systems

    … a novel method of minimising motion artefacts in biomedical instrumentation systems. The proposed solution, an Analog Frontend (AFE), was designed to detect any vertical (Y-Plane) or horizontal (X-Plane) movement of the electrode using two strain gauges, which were separated by 90° and fitted onto …

    oxford-brookes Repository record for Increasing Signal to Noise Ratio and Minimising Artefacts in Biomedical Instrumentation Systems (opens in a new tab) Download PDF for Increasing Signal to Noise Ratio and Minimising Artefacts in Biomedical Instrumentation Systems (opens in a new tab)

  4. A Low Power Mid-Rail Dual Slope Analog-To-Digital Converter for Biomedical Instrumentation

    <p>There are an estimated 15 million babies born preterm every year and it is on the rise. The complications that arise from this can be quite severe and are the leading causes of death among children under 5 years of age. Among these complications is a condition known as apnea. This disorder is …

    ut-knoxville Repository record for A Low Power Mid-Rail Dual Slope Analog-To-Digital Converter for Biomedical Instrumentation (opens in a new tab)

  5. Desenvolvimento e validação de uma plataforma multimodal de hardware aberto para aquisição, processamento e visualização de biossinais: contribuições para o ensino e a formação prática em engenharia biomédica

    Background: Practical training in Biomedical Engineering depends on the availability of laboratory resources capable of integrating knowledge from electronics, biomedical instrumentation, embedded systems, and digital signal processing. However, the high cost of commercial equipment and the limited …

    brazil-ufrn Repository record for Desenvolvimento e validação de uma plataforma multimodal de hardware aberto para aquisição, processamento e visualização de biossinais: contribuições para o ensino e a formação prática em engenharia biomédica (opens in a new tab)

  6. Design and implementation of a reconfigurable data acquisition integrated circuit

    … in a wide range of applications, including biomedical research, geophysics, gravitation measurements, telecommunication, power fault analysis, manufacturing process control and a wide variety of other test/measurement intensive fields. The primary objective of this research is to design and …

    vu-aus Download PDF for Design and implementation of a reconfigurable data acquisition integrated circuit (opens in a new tab)

  7. Fabrication and On-Machine Metrology of Precision Optics

    … ophthalmology, the automobile industry, biomedical instrumentation, and fundamental research. But due to stringent requirements on surface finish, limited choice of material that is suitable for optimal optical performance, and specific application-based demands, all of these are driving …

    arizona-thes Repository record for Fabrication and On-Machine Metrology of Precision Optics (opens in a new tab)

  8. Dislocation Reduction In Silicon Doped High Aluminum Content Algan Layers For Deep UV Optoelectronic Devices

    … of water and air purification, germicidal and biomedical instrumentation systems, etc. Due to the lack of native substrates and poor carrier injection, AlGaN-based deep UV LED is suffering from low optical power and low overall efficiency, which prevents the availability of low cost, high …

    south-carolina Repository record for Dislocation Reduction In Silicon Doped High Aluminum Content Algan Layers For Deep UV Optoelectronic Devices (opens in a new tab)

  9. Structural and Morphological Analyses of Aln and Algan Layers

    … of water and air purification, germicidal and biomedical instrumentation systems and others. Due to the lack of native substrates, sapphire is being used most abundantly for growing III-nitride based deep-UV device structures. Due to highly lattice mismatched hetero epitaxial growth of deep-UV …

    south-carolina Repository record for Structural and Morphological Analyses of Aln and Algan Layers (opens in a new tab)

  10. Design of Wireless Power Transfer and Data Telemetry System for Biomedical Applications

    <p>With the advancement of biomedical instrumentation technologies sensor based remote healthcare monitoring system is gaining more attention day by day. In this system wearable and implantable sensors are placed outside or inside of the human body. Certain sensors are needed to be placed inside …

    utk-theses Repository record for Design of Wireless Power Transfer and Data Telemetry System for Biomedical Applications (opens in a new tab)

  11. Development and evaluation of a portable automatic test system for clinical use

    <p>The intensifying development of biomedical instrumentation is having a major impact on the delivery of health care. All of the diagnostic, monitoring and theraputic equipment within a hospital must be inspected.on a regular bases to insure proper operation and patient safety. In this project an …

    ut-knoxville Repository record for Development and evaluation of a portable automatic test system for clinical use (opens in a new tab)

  12. Direct digital synthesis by analogue interpolation

    … low resolution frequency synthesis in biomedical instrumentation systems. To meet both these needs a new ROM-less architecture is presented here that uses less than half the circuit area of previous state of the art systems and improves the efficiency by operating at up to a tenth of …

    oxford Repository record for Direct digital synthesis by analogue interpolation (opens in a new tab)

  13. Improving Peripheral Nerve Modulation with Miniature Implants Interfaced with Ultrasound

    Implantable devices hold great promise for treating disorders of the peripheral nervous system (PNS). By delivering targeted electrical stimulation, they can modulate abnormal neural activity and alleviate symptoms. However, how implant configurations, such as size and electrode arrangement, affect …

    unsw Repository record for Improving Peripheral Nerve Modulation with Miniature Implants Interfaced with Ultrasound (opens in a new tab)

  14. A new portable High Density Surface EMG Multichannel Acquisition System

    The research and development of biomedical instrumentation for the detection and measurement of the electrical activity generated by the human body is an innovative sector of engineering that is in continuous evolution. The biopotential measurement by non-invasive techniques is a currently booming …

    poli-torino Repository record for A new portable High Density Surface EMG Multichannel Acquisition System (opens in a new tab)

  15. Electrochemical sensor system architecture using the CMOS-MEMS technology for cytometry applications

    … further integration and miniaturisation of the biomedical instrumentation. The two vertically stacked 4 x 4 flow-through sensor arrays, embedded into an on-chip membrane, were implemented in a single silicon chip device together with a readout circuitry for each of the sensor sets. To develop a …

    glasgow Download PDF for Electrochemical sensor system architecture using the CMOS-MEMS technology for cytometry applications (opens in a new tab)

  16. Projeto e avaliação de um canal de medição de bioimpedâncias

    Esta dissertação trata do projeto e avaliação de um canal de medição de bioimpedâncias multifrequencial cujo objetivo é a medida em módulo e fase de impedâncias até 1 k com desempenho reportado nas freqüências 100 kHz, 300 kHz e 1 MHz. Um modelo teórico foi desenvolvido para cada etapa do canal de …

    brazil-ufrgs Repository record for Projeto e avaliação de um canal de medição de bioimpedâncias (opens in a new tab)

  17. Non-invasive kinematic analysis of knee joints using ultrasound

    … registration for applications in the domain of biomedical research and treatment planning related to knee joints. Kinematic analysis allows the motion of individual bones in the knee joint to be measured. These motion measurements provide significant insights into normal and abnormal joint …

    unsw Repository record for Non-invasive kinematic analysis of knee joints using ultrasound (opens in a new tab)

  18. Wearable technologies for knee health monitoring using bioimpedance and acoustical emissions

    The objective of this work is to address the gap in the area of wearable knee joint health assessment. Knee injuries are among the most common reasons for doctor’s visits. The physical examinations of the joint during these visits are typically limited to qualitative observations. Examination …

    gatech Repository record for Wearable technologies for knee health monitoring using bioimpedance and acoustical emissions (opens in a new tab)

  19. Aquisição, processamento de sinais mioelétricos e máquina de vetores de suporte para caracterização de movimentos do segmento mão-braço

    As diversas áreas da Engenharia, em parceria com a ciência médica, têm contribuído de forma eficaz para o avanço do conhecimento e dos resultados em aplicações práticas na vida do deficiente físico. De forma geral, pesquisas com este foco têm permitido o desenvolvimento de dispositivos e recursos …

    brazil-ufrgs Repository record for Aquisição, processamento de sinais mioelétricos e máquina de vetores de suporte para caracterização de movimentos do segmento mão-braço (opens in a new tab)

Page 1 of 2