Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"Biosensors--Design and construction."”

  1. Development of a fluorescence resonance energy transfer optical nanoscale biosensor based on a liquid-core waveguide platform

    In order to produce a more versatile, adaptable, and effective method for detection of biological analytes, a self-contained and robust fluorescent optical biosensor architecture utilizing fluorescence resonance energy transfer (FRET) is proposed. This biosensor architecture is then applied to a …

    missouri Repository record for Development of a fluorescence resonance energy transfer optical nanoscale biosensor based on a liquid-core waveguide platform (opens in a new tab)

  2. An Exploration of Electron-Excited Surface Plasmon Resonance for Use In Biosensor Applications

    … (eSPR) is investigated for potential use in biosensors. Optical SPR sensors are commercially available at present and these sensors are extremely sensitive, but have the tendency to be relatively large, expensive, and ignore the potentials of microelectronic technology. By employing the use …

    gatech Repository record for An Exploration of Electron-Excited Surface Plasmon Resonance for Use In Biosensor Applications (opens in a new tab)

  3. Calibration methodology for a microwave non-invasive glucose sensor.

    … than 20 million people in the United States, and there is an increasing desire to find a testing process that is non-invasive, easy to use, and safe for users. Microwave technology has improved greatly during recent years and is now seen more often in conjunction with biomedical research. …

    baylor Repository record for Calibration methodology for a microwave non-invasive glucose sensor. (opens in a new tab)

  4. Design of a microwave sensor for non-invasive determination of blood-glucose concentration.

    … of blood. Microwave sensors are non-destructive and non-contact measuring devices, making them ideal for the measurement of parameters in industrial processes. Current uses of microwave sensors range from measuring moisture content of corn chips to measuring concentration of a solute in water. If …

    baylor Repository record for Design of a microwave sensor for non-invasive determination of blood-glucose concentration. (opens in a new tab)

  5. Design and verification of a surface plasmon resonance biosensor

    … been researching sensors useful for detecting and quantifying events in biological molecular chemistry, for example, binding events. Our previous research has been based primarily on quartz resonators. This thesis describes the results of our initial research of Surface Plasmon Resonance (SPR) …

    gatech Repository record for Design and verification of a surface plasmon resonance biosensor (opens in a new tab)

  6. Development of a FRET biosensor to detect the pathogen mycoplasma capricolum

    … species of bacteria that invade any type of cell and are adaptable to changing environments. We are developing an optical biosensor based on Fluorescence Resonance Energy Transfer (FRET) for detection of these pathogens, specifically for M. capricolum. Three different anti-peptide antibodies, (E, …

    missouri Repository record for Development of a FRET biosensor to detect the pathogen mycoplasma capricolum (opens in a new tab)

  7. A microwave radiometer system for use in biomedical applications.

    … biomedical industry is a rapidly growing sector and demands are increasing for the production of safe and noninvasive technologies. With the current surge of diabetes, a very desirable application for these technologies is a non-invasive monitor for blood glucose level. Recently, microwave …

    baylor Repository record for A microwave radiometer system for use in biomedical applications. (opens in a new tab)

  8. Design of a real time optical sensor for continuous blood cell separation

    For continuous measurement and display of oxygen saturation and RBC content in blood during cell separation a reflection type optical sensor is designed based on the theoretical model using the photon diffusion theory. The prototype sensor consists of two arrays of light emitting diodes, red and …

    njit Repository record for Design of a real time optical sensor for continuous blood cell separation (opens in a new tab)

  9. Analysis of the Detection of Organophosphate Pesticides in Aqueous Solutions Using Polymer-Coated SH-SAW Devices

    … (OPs) have been found as contaminants in surface and ground waters, soil, and agricultural products. Because OPs are toxic compounds, rapid detection/monitoring of OPs in groundwater is necessary to allow for real-time remediation. Detection of OPs in water has already been demonstrated using …

    marquette Repository record for Analysis of the Detection of Organophosphate Pesticides in Aqueous Solutions Using Polymer-Coated SH-SAW Devices (opens in a new tab)