Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"Biphasic pulses"”.

  1. Biphasic Gene Electrotransfer Enhances Gene Delivery <i>In Vitro</i>

    … studies have explored the possibility of using biphasic (often referred to as bipolar) pulses, primarily for irreversible electroporation (IRE), which report reduced muscle contraction during pulse train application compared to monophasic pulses. Additional studies show improved transfection …

    odu Repository record for Biphasic Gene Electrotransfer Enhances Gene Delivery <i>In Vitro</i> (opens in a new tab)

  2. Microfluidics and Neural Interfaces Development for the Safe Direct Current Stimulator

    … its working to the use of charge-balanced, biphasic pulses to interact with target neurons using metal electrodes. Short biphasic pulses are used to avoid toxic electrochemical reactions at the electrode-tissue interfaces. Biphasic pulses are effective at exciting neurons, but quite limited …

    jhu Repository record for Microfluidics and Neural Interfaces Development for the Safe Direct Current Stimulator (opens in a new tab)

  3. Efficacy of Monophasic and Biphasic Pulsed Field Ablation Waveforms: A Model Study

    … atrial fibrillation (AF), where disorganized impulses cause the atria to quiver and pump blood inefficiently. As of 2025, AF affects over 10 million people. Aside from invasive surgical treatments, antiarrhythmic drugs, or one time cardioversions, atrial fibrillation is treated with catheter …

    calpoly Repository record for Efficacy of Monophasic and Biphasic Pulsed Field Ablation Waveforms: A Model Study (opens in a new tab)

  4. Optimal strategies for electrical stimulation with implantable neuromodulation devices

    … a neuromodulation technique that uses electrical pulses to modulate the activity of excitable cells to provide a therapeutic effect. Many past and present ES applications use rectangular current waveforms that have been well studied and are easy to generate. However, an extensive body of …

    liverpool-jm Repository record for Optimal strategies for electrical stimulation with implantable neuromodulation devices (opens in a new tab)

  5. The Combined and Differential Effects of Monophasic and Biphasic Repetitive Transcranial Magnetic Stimulation on ERP-Indexed Attentional Processing in Treatment-Resistant Depression

    … rTMS protocols that administer sinusoidal biphasic pulses achieve remission in less than the majority. However, monophasic pulses may yield higher success rates based on greater cortical excitation/neuromodulation strength. MDD is associated with altered P300 event-related potentials …

    ottawa-retro Repository record for The Combined and Differential Effects of Monophasic and Biphasic Repetitive Transcranial Magnetic Stimulation on ERP-Indexed Attentional Processing in Treatment-Resistant Depression (opens in a new tab)

  6. The factors influencing TMS mapping

    … current directions reduced map area, half-sine pulses produced smaller maps than biphasic pulses and muscle activation increased map area. This thesis shows that COG is largely robust to changes in the same factors. The findings from these experiments have important implications for TMS practice …

    birmingham Repository record for The factors influencing TMS mapping (opens in a new tab)

  7. An Externally Programmable Microcontroller Based Neural Stimulator

    … and amplitude control to produce selectable biphasic pulses to implanted electrodes. Stimulation parameters provided for are all combinations of rate from 1 to 255 pulses per second for 31 predefined rates; amplitudes from O to 9.9 mA in increments of 0.3 mA/step; and pulse durations of 80 to …

    marquette Repository record for An Externally Programmable Microcontroller Based Neural Stimulator (opens in a new tab)

  8. Avaliação do efeito da estimulação magnética transcraniana nos sinais de eletroencefalograma usando o Teste F Espectral e a função de coerência

    … magnetic stimulator used was adjusted to provide biphasic pulses that lasted 280 µs and magnetic field generated has 31 kT for the biggest intensity point, and a 257-channel EEG recording equipment, which has a delta-sigma converter with a 20000-Hz sampling rate and register of 1000 Hz, was used. …

    brazil-uerj Repository record for Avaliação do efeito da estimulação magnética transcraniana nos sinais de eletroencefalograma usando o Teste F Espectral e a função de coerência (opens in a new tab)

  9. Investigating the Effects of Controllable Pulse Parameter Transcranial Magnetic Stimulation on Neurophysiological and Clinical Response

    … response variability and hardware limitations to biphasic pulses restrict its efficacy. Controllable pulse parameter TMS (cTMS) enables delivery of monophasic pulses at high frequency, potentially offering improved neurophysiological and clinical outcomes. This thesis aimed to compare the effects …

    mcmaster Repository record for Investigating the Effects of Controllable Pulse Parameter Transcranial Magnetic Stimulation on Neurophysiological and Clinical Response (opens in a new tab)

  10. Activation of retinal ganglion cells following epiretinal electrical stimulation with hexagonally arranged bipolar electrodes

    … stimulus pulse. With 100 IJS/phase anodic-first biphasic pulses, threshold charge densities were 24.0 ± 11.2 and 7.7 ± 3.2 1JC/cm2 for 50 1-1m and 125 IJm diameter electrodes, respectively. The estimated chronaxie from the strength-duration relationship was 214 IJS. The short-latency responses of …

    unsw Repository record for Activation of retinal ganglion cells following epiretinal electrical stimulation with hexagonally arranged bipolar electrodes (opens in a new tab)

  11. DESIGN AND MATERIALS DEVELOPMENT OF A SELF-CONTAINED FREEFORM STIMULATOR FOR NON-PULSATILE NEUROMODULATION

    … are restricted to delivering charge-balanced, biphasic pulses due to safety constraints at the electrode-tissue interface. Maintaining zero net charge injection minimizes the risk of electrochemical reactions that can damage both the electrode and surrounding tissue. However, pulsatile …

    jhu Repository record for DESIGN AND MATERIALS DEVELOPMENT OF A SELF-CONTAINED FREEFORM STIMULATOR FOR NON-PULSATILE NEUROMODULATION (opens in a new tab)

  12. The influence of anesthesia and nicotine on dopamine signaling in the rat dorsal striatum

    … was placed above the medial forebrain bundle. Biphasic pulses (60 Hz, 60 pulses, 300μA) were sent through the bipolar stimulating electrode to evoke dopamine release. Electrodes were lowered, and optimized, until clear dopamine signals were evoked. Once clear and stable dopamine signals were …

    eastern-wash Repository record for The influence of anesthesia and nicotine on dopamine signaling in the rat dorsal striatum (opens in a new tab)

  13. Modelling and validating an enhanced transcranial magnetic stimulator for neuroscience and clinical therapies

    … voltage levels, allowing the approximation of pulses of arbitrary shape.</p> <p>In the first part of this thesis, I validated the PWM method by using computational modelling to compare the neuronal response to stimuli generated by the pTMS device and by a conventional transcranial magnetic …

    oxford

  14. Temporal information transfer by electrical stimulation in auditory implants

    … pps as reference. Additionally to the default biphasic pulse (single pulse) the experiment was performed with double pulses. The double pulse consists out of two biphasic pulses directly after each other and a small interpulse interval (IPI) in between. Three different IPIs (15, 50, and 150 µs) …

    wurz-thes Repository record for Temporal information transfer by electrical stimulation in auditory implants (opens in a new tab)