Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 40 for “"Bipolar Electrode"”.
-
Development of electrochemical methods for sensing at bipolar electrode arrays
… of electrochemical methods for sensing at bipolar electrode (BPE) arrays. Electrochemical sensors are in use in many aspects of everyday life from glucose meters to radon detectors. It is important to develop methods that continue to improve the sensitivity and reliability of these sensors. …
-
Wireless Electrochemistry: 3D Bipolar Electrode Systems towards Spatially Controlled Bioelectronic Function
Bipolar electrochemistry represents a fundamentally different approach to electrochemical control, enabling spatially resolved redox processes on electrically isolated electrodes through externally imposed electric fields rather than direct electrical connection. This wire-free paradigm offers …
-
Electrokinetic focusing of charged species at bipolar electrode in a microfluidic device
The development and characterization of bipolar electrode (BPE) focusing is described. BPE focusing is an electrokinetic equilibrium technique in which charged analytes are focused and locally enriched on an electric field gradient in the presence of a counter-flow. This electric field gradient is …
-
Integration of Microchip Electrophoresis with Bipolar Electrode-Based Electrochemical, Fluorescence, and Electrochemiluminescence Detection
The objective of this project was to develop a bipolar electrode-based microchip electrophoresis (ME) reporting system for detection of electrochemically-active analytes, specifically products formed due to interactions of reactive nitrogen and oxygen species (RNOS) with biomolecules such as …
-
Dielectrophoresis at wireless bipolar electrode arrays: Applications to the marker-free selection and detection of circulating tumor cells
… constraints such as the requirement that all electrodes must be connected via wire leads to the power source. Further, in DEP devices that employ insulating posts to shape the electric field, integration of these structures intended for cell capture with other features, such as chambers for …
-
Polymer Light-Emitting Electrochemical Cells Enhanced with Bipolar Electrode Arrays: In Situ Doping and Formation of Multiple p-n Junctions
… is very narrow and highly inefficient. Adding bipolar electrodes (BPEs) into the active material of planar PLECs dramatically changes the doping process and improves the device performance in terms of response speed and efficiency. My research focuses on the study of how various BPEs and BPE …
-
The Influence of Bipolar Electrochemical Cell Geometry on the Studies of Pitting Corrosion
Bipolar electrochemistry (BPE) is a technique that provides a wireless alternative totraditional electrochemistry to elicit redox reactions. It has been utilized in different applications, including studying localized corrosion, gradient electrodeposition, propulsion of micromotors, and water …
-
Electrochemically generating electric field gradients in the absence of buffer for membrane-free separations
… approach utilized water electrolysis at a bipolar electrode in the absence of buffer to locally vary solution conductivity and the amount of ionic current that passed through a microfluidic device. Experiments and finite element simulations were performed to confirm the presence of sharp …
-
Multidoman Piezo-Ceramic Cantilever
… model with inversely poled domains and uniform electrode configuration as well as a single crystal cantilever model with uniformly poled crystal and bipolar electrode configuration. It was shown that cantilevers that are less oblong in shape could benefit from the bipolar electrode configuration …
-
Development of Fluorescence-Enabled Electrochemical Microscopy for Electrochemical Imaging and Detection
… in Chapter 3, which demonstrates the use of a bipolar electrode array to image dynamic concentration gradients in 2- and 3-dimensions. Chapter 4 moves on to a discussion of the use of electrogenerated chemiluminescence (ECL) as an optical reporter on closed bipolar electrodes as an alternative …
-
Cardiovascular health: from cardiomyocyte electrostimulation to miRNA detection
… stimulation of cardiomyocytes using wireless bipolar electrochemical techniques. The work describes the design and characterisation of a wireless bipolar electrode and wireless bipolar electrochemical cell to facilitate wireless bipolar electrostimulation. By using a wireless connection more …
-
Restoring Sensation of Gravitoinertial Acceleration through Prosthetic Stimulation of the Utricle and Saccule
… of rotational and translational stimuli; custom electrode arrays with fifty contacts targeting the SCCs, utricle and saccule; and a general-purpose neuroelectronic stimulator for vestibular and other neuromodulation applications. Using these new technologies, OORs were first characterized in six …
-
Automated decomposition of electromyographic signals recorded with surface electrode arrays
… we invented 1) a brush-tip pin (BTP) electrode made of a bundle of fine wires for contacting the skin without electrolytic jelly; 2) a miniature active surface electrode array consisting of the BTP electrodes and signal buffers built into the device for sampling the MUAPs distributed …
-
Surface electromyography based speech recognition system and development toolkit
… signals. Data collection was done using a bipolar electrode configuration with a sampling rate of 5.77 kHz. Four feature sets, the short-time Fourier transform (STFT), the dual-tree complex wavelet transform (DTCWT), a non-causal time-domain based (E4-NC), and a causal version of E4-NC …
-
Combined effects of prozac and hypothalmic mediated response on masseter muscle activity in the cat
… were utilized during the experiments. Cannula-electrodes were implanted into the medial hypothalamus for elicitation of defensive rage behavior. EMG activity was recorded with a bipolar electrode attached to the masseter muscle to establish baseline before the infusion of the drug. Mean …
-
Cortical Modulation of Spinal Reflexes in Healthy Humans
… foot with a 30 ms pulse train every 10 s via a bipolar electrode and recorded from the ipsilateral tibialis anterior (TA) muscle. Across subjects, medial edge foot stimulation was delivered at 1.2 to 1.5 times the response threshold. The soleus H-reflex was evoked and recorded via conventional …
-
New Tools for Studying Nanoscale Electrochemical Phenomena
… and nanoscale electrochemical structures such as electrodes, electrode arrays, and nanopores. It also discusses the use of these tools in studying nanoscale electrochemical processes such as geometric considerations in redox molecule diffusion to nanoscale electrodes, confined diffusion within …
-
Improving the stimulation selectivity in the human cochlea by strategic selection of the current return electrode
… cochlear fibers were investigated for monopolar, bipolar, tripolar, and a novel (distant) bipolar electrode configuration using an active compartmental nerve model based on Schwartz-Eikhof-Frijns membrane dynamics. The results suggest that skipping of the stimulation point from the vicinity of the …
-
Bipolar electrochemistry for enrichment, separations, and membraneless electrochemically mediated desalination
Developments in bipolar electrochemistry for the simultaneous separation and enrichment of charged species and membraneless electrochemically mediated desalination (EMD) are presented. Each of these techniques requires an electrochemically generated local electric field within a microchannel and …
-
The influence of electrode placement over the innervation zone on electromyographic amplitude and mean power frequency versus isokinetic and isometric torque relationships
… investigation was to examine the influence of electrode placement over the estimated innervation zone (IZ) for the vastus lateralis, as well as proximal and distal to the estimated IZ, on the torque-related patterns for electromyographic (EMG) amplitude and mean power frequency (MPF) during …
Page 1 of 2