Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"Birdcage coil"”
-
A high-pass detunable quadrature birdcage coil at high-field
… energy. The circuit that does this is called a birdcage coil. This coil is capable of producing a very homogenous B1 field over a large volume; it is this aspect of birdcage coils that make them very favorable for animal/human studies as it is necessary that all nuclei in the volume of the coil …
-
Measurement of the magnetic field of an RF-encoding birdcage-coil design for magnetic resonance imaging
… depends on the use of magnetic field gradient coils to visualize tissue. However, there is an alternate method, which can only use RF to encode the image. The idea behind RF encoding is that it uses spatial phase variation in the RF transmission to encode spatial information in the MRI signal …
-
Design and Optimization of a Miniature Radiation Pattern Reconfigurable Antenna for 2.4 GHz Band and a Dual Tuned Birdcage Coil for Magnetic Resonance Imaging
… antenna and optimization of a dual tuned birdcage coil. The design goals for the miniature reconfigurable antennas are resonance center frequency of 2.44 GHz, bandwidth of 2.4 GHz - 2.48 GHz, size of 0.8 cm x 1.2 cm, radiation efficiency of 70%, pattern correlation coefficient of 0.3 and …
-
The Fabrication and Characterization of a Superconducting Birdcage Resonator
… and characterization of a superconducting Birdcage style radiofrequency (RF) coil, a commonly used coil design in nuclear magnetic resonance (NMR) spectrometers. The Birdcage was fabricated from a series of superconducting Niobium thin film resonators, deposited onto sapphire wafer by …
-
The Electromagnetic Simulation of Birdcage Coils for MRI based on Finite Element Method
Radio frequency birdcage coils are widely used in clinical magnetic resonanceimaging. In order to effectively design a birdcage coil, optimum capacitance calculation on the rungs or end rings is critical. Several methods are discussed in this thesis to calculate the capacitance. The first method is …
-
Parallel Radiofrequency Transmission for the Reduction of Heating in Deep Brain Stimulation Leads at 3T
… field to suppress coupling effects. Three pTx coil configurations with 2-elements, 4-elements, and 8-elements, respectively, were investigated. Optimal input voltages to minimize coupling, while maintaining RF magnetic field homogeneity, were determined using a Nelder-Mead optimization …
-
Simulation of Electromagnetic Effects in Magnetic Resonance Imaging
… time, is employed to analyze the open RF coils in an MRI system. The FD-TD method, known for its ability to handle large and complex geometries, is applied to shielded birdcage coil analysis. Besides studying the field information inside the human head, the RF coil's resonant frequency …
-
Simulation and development of RF resonators for preclinical and clinical 1H and X-nuclei MRI
… highly efficient and homogeneous transmit (Tx) coils both increasing image quality and reducing measurement time. Radio frequency (RF) systems for MRI are designed to provide highest signal-to-noise ratio (SNR) while keeping the specific absorption rate (SAR) as low as possible. Due to the …
-
Proton diffusion spectroscopy and modeling of brain metabolism at 14.1T
… design and construction of a combined transmit-birdcage coil and receive-quadrature pair surface coil was considered. Its performance was compared to a single birdcage coil in the transmit/receive mode. So far, the preliminary results of the 2-coil configuration are promising: homogenous …
-
Methods to Enhance Nuclear Magnetic Resonance Sensitivity at High Magnetic Field
… hyperpolarized MRI. While MRI requires RF coils that generate high B1 homogeneity, MRS strongly depends on high sensitivity and potentially high B1 efficiency to allow for short-TE acquisitions. Two custom-made 1H coils resonating at 600 MHz, a single-channel saddle coil and an 8-leg …
-
Design of a Transceive Coil Array for Parallel Imaging at 9.4T
… and develop a transmit/receive (transceive) coil array for small animal imaging at 9.4T. The goal is achieved by following basic RF design principles with a methodical construction approach and demonstrating viable applications. As operational frequencies increase linearly with higher static …
-
RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI
… by the following approaches: (i) Exploration of coil designs capable of imaging both proton (1H – 63.8 MHz at 1.5T) and fluorine (19F – 60.1 MHz at 1.5T) nuclei involved: 1. The novel use of microelectromechanical systems to switch a single transceive vest coil between the two nuclei was compared …
-
Geometrically Decoupled Phased Array Coils for Mouse Imaging
Phased array surface coils offer high SNR over a large field of view. Phased array volume coils have high SNR at the surface and centre of the volume. Most array coil designs typically employ a combination of geometrical and additional techniques, such as isolating preamplifiers for …
-
Hardware Approaches for Enabling Multi-Channel Multinuclear MRI/MRS
… and the challenges in designing multinuclear RF coils hinder these studies. This dissertation proposes a multinuclear RF coil setup and implements two system modification approaches to overcome these challenges. In X-nuclear studies, the use of double-tuned or multi-tuned RF coils is crucial for …
-
Application of Parallel Imaging to Murine Magnetic Resonance Imaging
… element design in a 10-channel adjustable array coil for mouse imaging is presented, styled as a human cardiac top-bottom half-rack design. The design and construction of the homogenous transmit birdcage coil used is also described, one of the necessary components to eliminating the active …
-
An optimized RF coil for sensitive 31P magnetic resonance spectroscopic imaging of the human brain at 7 T
… of highly sensitive UHF 31P radiofrequency (RF) coils. The high sensitivity of such RF coils, combined with the enhanced SNR at UHF, is expected to facilitate more accurate and detailed investigations of brain energy metabolism in healthy and diseased conditions. In this thesis, we present the …
-
Metasurface Technology for Ultrahigh Field MRI
… In addition, traditional quadrature volume coil designs (birdcage, TEM coils), which are common for lower field strengths, become highly sensitive to patient loading at ultrahigh fields. Parallel transmit arrays and B1 shimming are effective at countering the field inhomogeneities, but are …
-
Experimental and computational EM analysis of MRI RF coils and of their interaction with implanted conductive objects
Radio frequency (RF) coils are employed in Magnetic Resonance Imaging (MRI) to excite and detect the signal from nuclear spins at Larmor frequency. The intrinsic complexity of the phenomena involved inside an MR scanner leads to strong requirements on the magnetic field B1 generated by the RF coil …
-
Bobines volumiques à base de métamatériaux pour l’imagerie par résonance magnétique à très haut champ
Le travail présenté dans ce manuscrit vise à créer un nouveau type de bobine volumique dédié à l’imagerie par résonance magnétique ultra haut champ (B0 ≥ 7 T) dérivé de la cage à oiseaux bien connue. Son design s'inspire des travaux sur les métamatériaux. Sur la base d’une analyse en termes de …
Page 1 of 2