  1. Comparison of separate measurement procedures for determination of GFR in chronic kidney disease

    … (CCC) showed almost perfect agreement (ρ>0.99). Bland-Altman analysis illustrated a mean bias of 1.70%. For iohexol-derived GFR results, Passing-Bablok regression illustrated a slope value of 1.00 (95% CI: 0.94, 1.04), and an intercept value of 0.28 ml/min/1.73m2 (95% CI: −3.05 - 3.96 …

    fu-berlin Repository record for Comparison of separate measurement procedures for determination of GFR in chronic kidney disease (opens in a new tab)

  2. Συσχέτιση της εκτίμησης της ταχύτητας μετάδοσης του σφυγμικού κύματος ανάμεσα στις συσκευές Arteriograph και Complior σε ασθενείς με καρδιαγγειακά νοσήματα

    … were calculated for each measurement. We used Bland-Altman analysis, intraclass correlation coefficient (ICC) and coefficient of variation (CV).Results: Bland-Altman analysis indicated a mean difference for PWV: i.0.5m/s (limits of agreement -1.4-2.4) between Complior and Mobil-O-Graph, …

    greece Repository record for Συσχέτιση της εκτίμησης της ταχύτητας μετάδοσης του σφυγμικού κύματος ανάμεσα στις συσκευές Arteriograph και Complior σε ασθενείς με καρδιαγγειακά νοσήματα (opens in a new tab)

  3. Resting Energy Expenditure in Athletes: Accuracy of Cunningham Prediction Equation Using DXA-Derived Fat Free Mass

    … to predict REE. A Wilcoxon signed-rank test and Bland-Altman analysis were used to determine respective difference and bias between measured and predicted REE. Results: Predicted REE by Cunningham equation using DXA-derived FFM was not statistically different from measured REE (Z = -1.306, p = …

    ku Repository record for Resting Energy Expenditure in Athletes: Accuracy of Cunningham Prediction Equation Using DXA-Derived Fat Free Mass (opens in a new tab)

  4. Resting Energy Expenditure in Athletes: Accuracy of Cunningham Prediction Equation Using DXA-Derived Fat Free Mass

    … to predict REE. A Wilcoxon signed-rank test and Bland-Altman analysis were used to determine respective difference and bias between measured and predicted REE. Results: Predicted REE by Cunningham equation using DXA-derived FFM was not statistically different from measured REE (Z = -1.306, p = …

    ku Repository record for Resting Energy Expenditure in Athletes: Accuracy of Cunningham Prediction Equation Using DXA-Derived Fat Free Mass (opens in a new tab)

  5. Comparison of the resonance sonorheometry based Quantra® system with rotational thromboelastometry ROTEM® sigma in cardiac surgery – a prospective observational study

    … was recorded. Spearman rank test correlation and Bland Altman analysis were performed. Results: Clot stiffness parameters of the Quantra correlated strongly with corresponding measurements of the ROTEM with r = 0.93 and 0.94 for EXTEM A10 vs CS and r = 0.94 and 0.96 for FIBTEM A10 vs FCS for …

    zurich

  6. Three dimensional body imaging for assessment of body composition

    … volume, and % fat were examined in 70 women. Bland-Altman analysis indicated minimal error in girth of the waist and hip by laser imaging as compared to tape measure (95% limits of agreement for waist, -2.02-2.29 cm; hip, -3.39-2.90 cm). Volume by laser imaging was related to hydrodensitometry …

    texas Repository record for Three dimensional body imaging for assessment of body composition (opens in a new tab)

  7. RELIABILITY ANALYSIS OF TIME-DOMAIN FUNCTIONAL NEAR-INFRARED SPECTROSCOPY IN DIAGNOSIS OF DEPRESSION

    … extracted using diffusion models. Statistical analysis identified features that significantly differentiated groups. Machine learning classifiers, particularly decision trees, were developed using VFT-derived features and achieved an average accuracy of 71.0% (±3.2%) in five-fold …

    nus Repository record for RELIABILITY ANALYSIS OF TIME-DOMAIN FUNCTIONAL NEAR-INFRARED SPECTROSCOPY IN DIAGNOSIS OF DEPRESSION (opens in a new tab) Download file for RELIABILITY ANALYSIS OF TIME-DOMAIN FUNCTIONAL NEAR-INFRARED SPECTROSCOPY IN DIAGNOSIS OF DEPRESSION (opens in a new tab)

  8. The Effects of Passive Hallux Adduction on Posterior Tibial Artery Blood Flow Compared to the Lateral Plantar Artery

    … data was assessed with paired t-tests and Bland-Altman plots (alpha = 0.05). RESULTS: There was an expected decrease in blood flow within each artery after passive hallux adduction (p < 0.001). The volume of blood flow differed between the arteries (p < .0001), but the change between …

    byu Repository record for The Effects of Passive Hallux Adduction on Posterior Tibial Artery Blood Flow Compared to the Lateral Plantar Artery (opens in a new tab) Download PDF for The Effects of Passive Hallux Adduction on Posterior Tibial Artery Blood Flow Compared to the Lateral Plantar Artery (opens in a new tab)

  9. The application of 4D cardiac CT segmentation for pre-operative and post-operative transcatheter pulmonary valve replacement

    … 4D CTA. In addition, the correlation analysis between the anatomical model and straightened model was also conducted by means of Pearson correlation and Bland-Altman analysis. Results: The clear structure of each section from RVOT to PA were observed on straightened model. Significant …

    fu-berlin Repository record for The application of 4D cardiac CT segmentation for pre-operative and post-operative transcatheter pulmonary valve replacement (opens in a new tab)

  10. Reliability and Validity of the Body Caliper to Evaluate Body Composition

    … The validity of the Body Caliper was assessed by Bland-Altman analysis and was proven valid by 96% of the sample reaching agreement between the two methods. The results of this study have demonstrated the Body Caliper to be a reliable and valid instrument and method for evaluating body composition.

    unlv Repository record for Reliability and Validity of the Body Caliper to Evaluate Body Composition (opens in a new tab) Download PDF for Reliability and Validity of the Body Caliper to Evaluate Body Composition (opens in a new tab)

  11. Monitoring Decelerations: GPS Sensitivity, Specificity, and Biomechanical Responses

    … the same zones identified by motion capture. Bland-Altman analysis was utilized to assess the agreement between the systems. For aims 2 and 3, participants completed an exercise intervention to accumulate 30 high-intensity deceleration movements before repeating the ADA and 505 COD tasks. …

    ecu Repository record for Monitoring Decelerations: GPS Sensitivity, Specificity, and Biomechanical Responses (opens in a new tab)

  12. Noninvasive evaluation of cardiac function using Computed Tomography and Magnetic Resonance Imaging

    … volume (SV), and left ventricular mass (LVM). Bland Altman analysis was used in the assessment of differences between modalities and limits of agreement (LoA) were provided. Cochran’s Q test and Higgins I2 statistic were used for the evaluation of heterogeneity. Estimation of heterogeneity …

    fu-berlin Repository record for Noninvasive evaluation of cardiac function using Computed Tomography and Magnetic Resonance Imaging (opens in a new tab)

  13. Towards the use of 2-dimensional video-based markerless motion capture to objectively evaluate kinematics during functional capacity evaluation

    … Three floor-to-waist height lifts were used for analysis for each participant (N = 20). Participants’ lifts were captured using 3D motion capture (Vicon, Oxford, UK) and simultaneously recorded using 2D video (camcorder) in the sagittal plane. The participants lifts were each completed using a …

    waterloo Repository record for Towards the use of 2-dimensional video-based markerless motion capture to objectively evaluate kinematics during functional capacity evaluation (opens in a new tab)

  14. Cinko koncentracijos nustatymo žmogaus kraujo serume atominės absorbcinės spektroskopijos ir spektrofotometrijos metodais palyginimas /

    … compared using Passing – Bablok regression and Bland - Altman analysis, it gave the following results: intercept = -4,4636 (95% CI -7,0279 to -2,2227), slope = 1,1071 (95% CI 0,9766 to 1,2611). Both methods showed good correlation r = 0,83258 (p<0,05). In conclusion, both methods are suitable …

    vilnius Repository record for Cinko koncentracijos nustatymo žmogaus kraujo serume atominės absorbcinės spektroskopijos ir spektrofotometrijos metodais palyginimas / (opens in a new tab)

  15. Evaluation of Virtual Reality-Based Diagnostic Devices in Tertiary Care Ophthalmology

    … was evaluated using Pearson correlation and Bland–Altman analysis, while pointwise threshold agreement was assessed through heatmap visualizations and spatial analyses. Pupillary assessment focused on the detection and categorical grading of a relative afferent pupillary defect (RAPD), with …

    ottawa-retro Repository record for Evaluation of Virtual Reality-Based Diagnostic Devices in Tertiary Care Ophthalmology (opens in a new tab)

  16. Doppler radar sensing of fish physiological motion

    … systems. Original research contributions include analysis for radar operation under water, development of radar systems for aquatic operation, and application of these systems to non invasively sense the heart and gill motion of fish. Tilapia and Sturgeon were studied to test the efficacy across …

    hawaii Repository record for Doppler radar sensing of fish physiological motion (opens in a new tab)

  17. Depression, Anxiety, and Estimated Cardiorespiratory Fitness in College Students

    … to be calculated within the eCRF algorithm, a Bland Altman Analysis was conducted. There were no statistically significant findings among all analyses including 1) assessment of the association of eCRF with depression, 2) assessment of the association of eCRF with anxiety, 3) determination of …

    unlv Repository record for Depression, Anxiety, and Estimated Cardiorespiratory Fitness in College Students (opens in a new tab) Download PDF for Depression, Anxiety, and Estimated Cardiorespiratory Fitness in College Students (opens in a new tab)

  18. Measurement of Cystatin C in Dried Blood Spot Specimens

    … (95% confidence interval=0.92 to 1.12), R=0.94. Bland Altman analysis of cysC concentrations in DBS vs. plasma revealed no bias and acceptable levels of agreement (Bias -0.02, 95% confidence interval=-0.21 to 0.17). The DBS-ELISA demonstrates utility as a screening tool; sensitivity and …

    washington Repository record for Measurement of Cystatin C in Dried Blood Spot Specimens (opens in a new tab)

  19. Unmanned Aerial Vehicle Based Structure from Motion Biomass Inventory Estimates

    … 7 feet. The project site was divided into four analysis sections, one for derivation of parameters used in the UAV data analysis, and the remaining three sections reserved for method validation. The most conservative of several methods tested comparing the ground truth data to the UAV generated …

    portland-state Repository record for Unmanned Aerial Vehicle Based Structure from Motion Biomass Inventory Estimates (opens in a new tab)