Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 46 for “"Bland-Altman plot"”.

  1. Objective Statistics For The Measurement Of Agreement

    … biomedical device interchangeability is a scatterplot of means and differences bounded by levels of agreement (Bland-Altman Plot) which results in subjective judgments made in the discernment of differences in data distribution and fit. The purpose of this study was to test four statistics - the …

    wayne-thes Repository record for Objective Statistics For The Measurement Of Agreement (opens in a new tab)

  2. Evaluation of Two Methods to Estimate Wet Bulb Globe Temperature from Heat Index

    … of ∆WBGT was computed for each method and a Bland-Altman plot was made. The slope of the line in the Bland-Altman plot was also determined and whether it was significantly different from zero. The accuracy was assessed by the mean ∆WBGT and the precision by the standard deviation. The …

    usf Repository record for Evaluation of Two Methods to Estimate Wet Bulb Globe Temperature from Heat Index (opens in a new tab)

  3. Predicting Barbell Takeoff Speed from Peak Speed in the Bench Press Throw using a Linear Position Transducer

    … significant (R2=0.961, p < 0.05). A Bland-Altman plot revealed the 95% limit of agreement ranged from 0.262 m∙s-1 to 0.175 m∙s-1, with a mean difference of 0.043 m∙s-1 (2.92%), and points above and below zero, suggesting no systematic bias exists. This study demonstrates that takeoff …

    uvic Repository record for Predicting Barbell Takeoff Speed from Peak Speed in the Bench Press Throw using a Linear Position Transducer (opens in a new tab)

  4. Comparison Of Readability Indices With Grades 1-5 Narrative And Expository Texts

    … Fifteen (15) comparison sets were analyzed using Bland-Altman method to assess for agreement. An a priori set standard of 1.5 grade levels was used as an acceptable difference. Other considerations for agreement included narrow limits of agreement, low proportional error, and a Bland-Altman plot …

    wayne-thes Repository record for Comparison Of Readability Indices With Grades 1-5 Narrative And Expository Texts (opens in a new tab)

  5. Validação da versão eletrônica do Pediatric Asthma Control and Communication Instrument - PACCI

    … consistency and test-retest), paired t-test and Bland-Altman plot were analyzed for agreement analysis and correlation tests. Results: The sample consisted of 62 participants. Reliability measures indicate adequate internal consistency (Cronbach's α = 0.84) and good agreement in the CCI …

    brazil-ufrn Repository record for Validação da versão eletrônica do Pediatric Asthma Control and Communication Instrument - PACCI (opens in a new tab)

  6. Head above water weighing: A valid method to measure body fat storage?

    … above water at total lung capacity (HAWTLC). Bland-Altman Plots were created and regression analyses were used to test for proportional bias across the range of means. Results: There was no significant difference between HAWRV and UWWRV for both males and females. However, a Bland-Altman plot …

    northern-iowa Repository record for Head above water weighing: A valid method to measure body fat storage? (opens in a new tab)

  7. Correlacion entre bilirrubinometría transcutanea y bilirrubina serica en neonatos a termino o cercanos al termino con ictericia

    … serum bilirubin. Correlation is shown as scatter plots, and the Pearson correlation index for chest or forehead was calculated. Variability of differences between transcutaneous levels and serum bilirubins was shown using a Bland-Altman plot. Test performance with sensitivity and specificity was …

    rosario Repository record for Correlacion entre bilirrubinometría transcutanea y bilirrubina serica en neonatos a termino o cercanos al termino con ictericia (opens in a new tab)

  8. STATISTICAL METHODS FOR THE ASSESSMENT OF WITHIN-PLAFORM REPEATABILITY AND BETWEEN-PLATFORM AGREEMENT IN MICRORNA MICROARRAY TECHNOLOGIES

    … has been studied using a modifed version of the Bland-Altman plot which makes use of a linear measurement error to build the agreement intervals. All the analysis have been performed on unfiltered and non-normalized data, yet all results have been compared to those obtained after applying …

    milano Repository record for STATISTICAL METHODS FOR THE ASSESSMENT OF WITHIN-PLAFORM REPEATABILITY AND BETWEEN-PLATFORM AGREEMENT IN MICRORNA MICROARRAY TECHNOLOGIES (opens in a new tab)

  9. Aplicação de um modelo cinemático tridimensional para predição de volume corrente em recém-nascidos: um estudo piloto

    … kilogram of weight for each NB (5 ml/kg), on a Bland-Altman plot. Results: Thirteen NBs (gestational age: 39.1±0.8 weeks), with a mean weight and length of 3175.4±493.8g and 49±2.8cm, respectively, were included in the study. TV estimated by the kinematic analysis was 16.3±4.2 ml or 5.1 ml/kg …

    brazil-ufrn Repository record for Aplicação de um modelo cinemático tridimensional para predição de volume corrente em recém-nascidos: um estudo piloto (opens in a new tab)

  10. The Effect of Varying Cadence in Cycle Ergometry on Submaximal Predictions of Peak Oxygen Uptake

    … maximal test to determine variability and error. Bland-Altman plot analysis revealed the standard YMCA protocol of 50-rpm underestimated 67.5% of the participant's predicted peak VO2 scores with large variability in all predictions with a standard deviation of 0.844 liters/minute. The 70-rpm …

    wku-diss Repository record for The Effect of Varying Cadence in Cycle Ergometry on Submaximal Predictions of Peak Oxygen Uptake (opens in a new tab)

  11. Informant Discrepancies in the Assessment of Social-Communication Skills and Behavioral/Interest Flexibility and Regulation of Children Diagnosed with Autism Spectrum Disorder Without Intellectual Disability

    … in discrepancies across the range of scores, a Bland-Altman Plot and regression analysis were used. There were no systematic differences across the range of scores. No child or caregiver demographic variables significantly moderated caregiver-teacher discrepancies. This study suggests that …

    buffalo Repository record for Informant Discrepancies in the Assessment of Social-Communication Skills and Behavioral/Interest Flexibility and Regulation of Children Diagnosed with Autism Spectrum Disorder Without Intellectual Disability (opens in a new tab)

  12. Examining the Use of Two-Dimensional Video Capture and a Pressure Sensing Walkway for Collection of Obstacle Crossing Measures

    … one-sample t tests. Agreement was assessed via Bland-Altman plot analysis and a linear regression. Lastly, intraclass correlations assessed reliability between trials. Generally, 2D video analysis performed poorly compared to 3D motion capture, for accuracy, agreement, and reliability. The …

    arkansas Repository record for Examining the Use of Two-Dimensional Video Capture and a Pressure Sensing Walkway for Collection of Obstacle Crossing Measures (opens in a new tab)

  13. Utilização de inteligência artificial para mensurar a espessura do palato em tomografias computadorizadas com vistas à técnica marpe

    … Intraclass Correlation Coefficient (ICC), and Bland-Altman plots. Results: The model achieved an MRE of 1.13 ± 0.47 mm, and SDRs of 85%, 92.5%, and 97.5% within radii of 2.0 mm, 2.5 mm, and 3.0 mm, respectively. The global ICC for all the validation set exams reached a value of 0.66, with 5 out …

    brazil-ufrn Repository record for Utilização de inteligência artificial para mensurar a espessura do palato em tomografias computadorizadas com vistas à técnica marpe (opens in a new tab)

  14. The NEST study: NICOM vs ECHO in the screening of transient hypertrophic obstructive cardiomyopathy (HOCUM)

    … r = 0.5)). This was further assessed using a Bland Altman plot. Otherwise, univariate analysis of the transient HOCUM cohort was carried out using Chi Square tests for categorical variables and independent T-tests for continuous variables. Results: Fifty infants underwent echocardiography …

    cork Repository record for The NEST study: NICOM vs ECHO in the screening of transient hypertrophic obstructive cardiomyopathy (HOCUM) (opens in a new tab)

  15. Recommendations for Minimal and Optimal Amounts of Physical Activity to Reduce the Risk of Dyslipidemia in Youth

    … measurements. Regression analysis as well as a Bland-Altman plot was used to explain the discrepancy between self-reported and objective measures of MVPA. All analyses were completed using SAS statistical software. Results: Manuscript 1. Risks for high-risk HDL-cholesterol and triglyceride …

    queens Repository record for Recommendations for Minimal and Optimal Amounts of Physical Activity to Reduce the Risk of Dyslipidemia in Youth (opens in a new tab)

  16. Neuartiger telemetriefähiger Messansatz zur Bestimmung der Jodaufnahme der Schilddrüse im Rahmen des Radiojodtests mittels Sondenmessung direkt am Hals

    … und die Methoden mittels RC-Wert Analyse und Bland-Altman-Plot miteinander verglichen. Ergebnisse Die Berechnungen zeigen, dass sich zwei Kombinationen besonders positiv auszeichnen: zum einen „Anterior - 1,0 cm Abstand - K2“ und zum anderen „Schräg - ohne Abstand - K2“. Für die erste …

    fu-berlin Repository record for Neuartiger telemetriefähiger Messansatz zur Bestimmung der Jodaufnahme der Schilddrüse im Rahmen des Radiojodtests mittels Sondenmessung direkt am Hals (opens in a new tab)

  17. Der BOLD-Effekt - eine nicht-invasive Messung der Blutsauerstoffsättigung im Herzen mittels T2-MRT in einem Schweinemodell einer akuten systemischen Hyper- und Hypoxämie

    … abnahm. Die lineare Regressionsanalyse und das Bland-Altman-Plot zeigten sowohl im präklinischen Hauptversuch als auch in der klinischen Pilotstudie eine gute Übereinstimmung zwischen der nicht-invasiven ScvO2 mittels BOLD-Messung und der invasiven ScvO2 mittels Katheter (p<0,0001, r2=84% bzw. …

    fu-berlin Repository record for Der BOLD-Effekt - eine nicht-invasive Messung der Blutsauerstoffsättigung im Herzen mittels T2-MRT in einem Schweinemodell einer akuten systemischen Hyper- und Hypoxämie (opens in a new tab)

  18. Proposição de instrumentos de avaliação e critérios para triagem de fatores de risco cardiometabólico em adultos com excesso de peso

    … the Paired t-test, multiple regression and Bland-Altman plot were used. To determine cutoff points, the ROC curve was plotted based on sensitivity and specificity, in addition to identifying the area under the AUC curve. Diagnostic agreement was calculated using Kappa analysis. The equation …

    brazil-ufrn Repository record for Proposição de instrumentos de avaliação e critérios para triagem de fatores de risco cardiometabólico em adultos com excesso de peso (opens in a new tab)

  19. Psychometric Testing of a Polyphenol Screener

    … samples t-test, Pearson’s correlation, and a Bland-Altman plot, and were compared to urinary total polyphenols using Pearson’s correlation and the method of triads. Reliability was evaluated using Pearson’s correlation between repeat administrations of the PPS.Results Phase 1 (n=10) and Phase …

    nebraska Repository record for Psychometric Testing of a Polyphenol Screener (opens in a new tab)

  20. Reliable volume measurements in ADPKD patients: a study of MRI sequences

    … The intra-class correlation coefficient and Bland-Altman plot were used to describe correlation between kidney volumes, for intra-reader and inter-reader data respectively. RESULTS: Analyses show a significant difference in the repeated volume measurements from the T1 sequence in inter-reader …

    bu Repository record for Reliable volume measurements in ADPKD patients: a study of MRI sequences (opens in a new tab)

Page 1 of 3