Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 9 of 9 for “"Bloch simulations"”
-
Design of Pulse Sequences for Low-Field Cardiac MRI Using Bloch Simulations
… address these challenges, we employed MRI simulations, which have proven effective for optimizing imaging parameters at novel field strengths. Nevertheless, current MRI simulators have performance, ease of use, and extensibility problems. Consequently, a new open-source MRI simulator with …
-
Applications of magnetic resonance encephalography-spin-echo and multi-echo fMRI
… SE-MREG with TR=250 ms was optimized using Bloch simulations and implemented at 3.0 T using a twice-refocused spin-echo design. Compared to standard SE methods (SE-EPI and SE-SMS), SE-MREG showed superior detection of visual activation and resting-state networks and improved sensitivity to …
-
Construction and characterisation of ultra-thin alkali-metal vapour cells
… do not have sufficient agreement with an optical Bloch simulation, but Maxwell Bloch simulations indicate the possible presence of simultons; simultaneously propagating solitons. Such phenomena have not yet been observed out of crystalline media. We also present a study of causality relations in …
-
Application of Phase Imaging at High Field - MR Thermometry at 7 Tesla
… and quantified in experiments and magnetic field simulations. One way of correcting MR thermometry is to use a chemically shifted reference substance, in combination with a phase-sensitive chemical shift-selective MR thermometry sequence. The requirement of having a reliable separation of …
-
Parallel transmission technologies for imaging the brain and body with 7 tesla MRI
… to blood flow. Using extended phase graphs and Bloch simulations I investigated how this new method compares to those currently in use. I also investigated whether coil-cycling the acquisition of relative maps was beneficial and I found that coil-cycling is especially important when measuring 3D …
-
Deep Learning Methods for Ultra High Field MRI
… manner using a physics-driven loss derived from Bloch simulations, thereby eliminating the need for supervised labels or reference solutions. Compared to unregularized magnitude least-squares (MLS) designs, the proposed method achieves lower root-mean-square error, reduced coefficient of …
-
Ultrafast Laser-Induced Processes in Artificial Spin Ice
… response. Although finite-difference time-domain simulations ruled out optical resonances and the non-plasmonic character of NiFe excluded plasmonic effects, the limited reproducibility of the signals, and their sensitivity to the probe beam incidence angle, prevented a conclusive verification of …
-
B1 Mapping for Magnetic Resonance Imaging
… of a recent and popular B1 mapping method, the Bloch-Siegert shift (BSS) method, along with a comparison of the technique to other common B1 mapping methods. The statistical models developed in chapter 4 are verified using both Monte Carlo simulation and actual MRI experiments in phantoms. …
-
2D Radiofrequency Encoding: Radial TRASE MRI
… by these results, I wrote a Python-based Bloch-equation simulator to quantify the isolation requirements of Radial TRASE. At the same time, the trade-off between strong phase-gradient fields (related to spatial resolution) and B1 inhomogeneity was evaluated. The results of this simulation …