Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 39 for “"Block Shear"”

  1. Moment-induced block shear failure in bolted flange plate connections

    Block shear in bolted steel connections has been widely recognized and studied as a possible failure path for steel members under tension. However, despite their ubiquity in modern steel structures, the block shear failure mode has not been explicitly studied for W-sections with bolted flange plate …

    mcgill Repository record for Moment-induced block shear failure in bolted flange plate connections (opens in a new tab)

  2. Behaviour of Reduced-Scale Fully-Grouted Concrete Block Shear Walls

    … majority of the experimental research on masonry shear wall behaviour has been done on single storey walls and on piers in many cases due to physical and equipment limitations in laboratories or time and cost constraints. Although full scale testing of multi-storey masonry shear walls has been …

    mcmaster Repository record for Behaviour of Reduced-Scale Fully-Grouted Concrete Block Shear Walls (opens in a new tab)

  3. A numerical study on block shear failure of steel tension members

    Block shear is a limit state that should be accounted for during the design of the steel tension members. This failure mechanism combines a tension failure on one plane and a shear plane on a perpendicular plane. Although current design specifications present equations to predict block shear load …

    metu Repository record for A numerical study on block shear failure of steel tension members (opens in a new tab)

  4. Block shear failures in W-section tension members connected by bolted flange plates

    Des plaques de recouvrement boulonnées sont un moyen efficace pour les liaisons des profilés à ailes larges (profilés en I) au sein des charpentes résistantes au moment, des cadres à contreventements et des fermes d'acier. Les ailes des profilés endurent des efforts de traction élevés qui peuvent …

    mcgill Repository record for Block shear failures in W-section tension members connected by bolted flange plates (opens in a new tab)

  5. Investigating and Understanding the Behavior of a Titanium Alloy Gusset Plate Under Block Shear

    … designed geometric conditions that induce the block shear failure mode. Nine bolted gusset plates made of a titanium alloy were tested to failure. Experimental load-strain data was collected and compared with a non-linear material static finite element analysis. Once the analysis was verified …

    ohiolink Repository record for Investigating and Understanding the Behavior of a Titanium Alloy Gusset Plate Under Block Shear (opens in a new tab)

  6. Flexural Behavior of Interlocking Compressed Earth Block Shear Walls Subjected to In-Plane Loading

    … behavior of interlocking compressed earth block (ICEB) shear walls. In-plane cyclic tests were conducted to evaluate the performance of three flexure dominant large scale ICEB specimens: a slim wall with a 2:1 height to width aspect ratio, a flanged wall, and a wall with an opening at the …

    calpoly Repository record for Flexural Behavior of Interlocking Compressed Earth Block Shear Walls Subjected to In-Plane Loading (opens in a new tab)

  7. Bio-Inspired Artificial Intelligence Approach for Reinforced Concrete Block Shear Wall System Response Predictions

    Reinforced concrete block shear walls (RCBSWs) are used as seismic force resisting systems in low- and medium-rise buildings. However, attributed to their nonlinear behavior and composite material nature, accurate prediction of their seismic performance relying only on mechanics is challenging. …

    mcmaster Repository record for Bio-Inspired Artificial Intelligence Approach for Reinforced Concrete Block Shear Wall System Response Predictions (opens in a new tab)

  8. Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls

    … tests on fully-grouted reinforced masonry (RM) shear walls. The test walls covers a range of design parameters to facilitate benchmarking, a thorough performance investigation, and calibration of numerical models as well as development of fragility curves within the context of Performance Based …

    mcmaster Repository record for Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls (opens in a new tab)

  9. A Hybrid Mechanics-evolutionary Algorithm-derived Backbone Model for Unbonded Post-tensioned Concrete Block Shear Walls

    Unbonded post-tensioned concrete block (UPCB) shear walls are an effective seismic force resisting system due to their ability to contain expected damage attributed to their self-centering capabilities. A few design procedures were proposed to predict the in-plane flexural response of UPCB walls, …

    mcmaster Repository record for A Hybrid Mechanics-evolutionary Algorithm-derived Backbone Model for Unbonded Post-tensioned Concrete Block Shear Walls (opens in a new tab)

  10. The Effects of Bolt Pretension, In-Plane Eccentricity, and Friction on the Ductility of Block Shear Connections

    Block shear is a complex failure mechanism in bolted and welded steel components such as gusset plates, webs of coped beams, angles and tees. It presumes a combination of tension rupture and shear yield. Multiple variables affect the block shear capacity and ductility of a connection. This study …

    uconn-diss Repository record for The Effects of Bolt Pretension, In-Plane Eccentricity, and Friction on the Ductility of Block Shear Connections (opens in a new tab)

  11. A theoretical and experimental study of geometry, microstructure and mechanical properties of 316L stainless steel manufactured by direct energy deposition-based hybrid manufacturing

    … study, a new testing method which is called block shear test is developed to evaluate the substrate/deposited material interfacial bonding strength. To validate the results of the block shear test of DED part, a set of specimens are manufactured, using the machining process, and thereafter …

    iastate Repository record for A theoretical and experimental study of geometry, microstructure and mechanical properties of 316L stainless steel manufactured by direct energy deposition-based hybrid manufacturing (opens in a new tab)

  12. Predicting ductile fracture in steel connections

    … are dominated by either tension loading, shear loading, or a combination of both. In this study, a new ductile fracture criterion based on monotonic loading conditions is first developed based on analysis and definitions of the two stress state parameters and subsequently extended to the …

    colostate Repository record for Predicting ductile fracture in steel connections (opens in a new tab)

  13. Some gluing characteristics of ocotea usambarensis (engl.)

    … assembly times of each of the 4 glues, wood blocks approximately 25.4 x 101.6 x 304 mm (1 x 4 x 12 in) were bonded together. Gluing and pressing were carried out at room temperature (21-24°C). A pressing pressure of 1,379 kPa (200 psi) was applied over a period of 24 h. After conditioning, …

    ubc Repository record for Some gluing characteristics of ocotea usambarensis (engl.) (opens in a new tab)

  14. Assessing Bond Beam Horizontal Reinforcement Efficacy with Different End Anchorage Conditions in Concrete Block Masonry Shear Walls

    Reinforced concrete block shear walls are studied in this research. The main focus is to determine how the end anchorage conditions of bond beam horizontal reinforcement influences the behaviour of shear walls, and how to use reinforcement to improve shear wall performance by using smaller bar …

    calgary Repository record for Assessing Bond Beam Horizontal Reinforcement Efficacy with Different End Anchorage Conditions in Concrete Block Masonry Shear Walls (opens in a new tab)

  15. Durability and mode-I fracture of fiber-reinforced plastic (FRP)/wood interface bond

    … ASTM delamination test. Second, the apparent shear strengths of interface bond under both dry and wet conditions are obtained from modified ASTM block shear tests. Finally, a simplified design of an innovative contoured double cantilever beam (CDCB) specimen is developed, and this specimen is …

    wvu Repository record for Durability and mode-I fracture of fiber-reinforced plastic (FRP)/wood interface bond (opens in a new tab)

  16. An Investigation of the Influence of Tightening Torque and Sea Water on Pultruded GFRP Composite Bolted Joints

    … bolted joints are also studied. It is shown that blockshear failure mode is also a principal mode of failure in the bolted joints of these composites in addition to net-tension, bearing, shearout and cleavage. The results of these tests are analyzed using Load and Resistance Factor Design (LRFD) …

    odu Repository record for An Investigation of the Influence of Tightening Torque and Sea Water on Pultruded GFRP Composite Bolted Joints (opens in a new tab)

  17. Basic Testing and Strength Design of Corrugated Board and Containers

    … of the bending stiffness and the transverse shear stiffness. The transverse shear stiffness was also measured using a block shear test. It was shown that evaluated bending stiffness agrees with theoretically predicted values. However, evaluation of transverse shear stiffness showed …

    lund Repository record for Basic Testing and Strength Design of Corrugated Board and Containers (opens in a new tab)

  18. Evaluations of concrete overlays for bridge deck applications

    … interface behavior, a new compression loading block shear apparatus was developed, and for each type of overlay, double wedge-type bi-layer specimens of overlay-substrate were tested for two different substrate surface preparation conditions: Mechanical abrasion and chemical etching.;The …

    wvu Repository record for Evaluations of concrete overlays for bridge deck applications (opens in a new tab)

Page 1 of 2