Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 39 for “"Blood Damage"”.

  1. Simulations of pulsatile flow through bileaflet mechanical heart valves using a suspension flow model: to assess blood damage

    … severe complications still exist, and thus blood damage that occurs in BMHV flows must be well understood. The aim of this research is to numerically study platelet damage that occurs in BMHV flows. The numerical suspension flow method combines lattice-Boltzmann fluid modeling with the …

    gatech Repository record for Simulations of pulsatile flow through bileaflet mechanical heart valves using a suspension flow model: to assess blood damage (opens in a new tab)

  2. Development of a Blood Shear Stress Device using Numerical and Experimental methods

    … of LVADs to operate successfully without causing blood damage remains a challenge. Due to high fluid stresses for prolonged period, the circulatory components of a LVAD tend to cause mechanical destruction of red blood cells leading to the release of hemoglobin into the bloodstream, termed as …

    houston Repository record for Development of a Blood Shear Stress Device using Numerical and Experimental methods (opens in a new tab)

  3. A theoretical approach to the prediction of haemolysis in centrifugal blood pumps

    … strongly depends on the extent to which they damage blood. The development of a theoretical pump evaluation model was performed in this study to facilitate an effective pump optimisation. The optimisation process seeks to maximise flow performance and minimise blood trauma which is primarily …

    strathclyde Repository record for A theoretical approach to the prediction of haemolysis in centrifugal blood pumps (opens in a new tab)

  4. Analysis and experiments on flow-induced hemolysis.

    … stresses in flows within hypodermic needles, blood pumps, artificial hearts and other cardiovascular devices, is one of the major concerns during the design and use of cardiovascular or blood-processing extracorporeal devices. A non-invasive experimental method which does not interfere …

    louisville Repository record for Analysis and experiments on flow-induced hemolysis. (opens in a new tab)

  5. In vitro micro particle image velocimetry measurements in the hinge region of a bileaflet mechanical heart valve

    … platelet activation to identify potential for blood damage. However, experimental characterization of the whole flow fields within the valve hinges has not yet been conducted. This information can be utilized to investigate instantaneous damage to blood elements and also to validate numerical …

    gatech Repository record for In vitro micro particle image velocimetry measurements in the hinge region of a bileaflet mechanical heart valve (opens in a new tab)

  6. Computational Prediction Of Hemolysis In Laminar Non-Newtonian Fluid

    Hemolysis, the rupture of red blood cells (RBCs), is a critical concern in blood-circulating devices, requiring accurate predictions to ensure patient safety. This study investigates the sensitivity of hemolysis predictions to variations in viscosity models and hemolysis coefficients under complex …

    nodak Repository record for Computational Prediction Of Hemolysis In Laminar Non-Newtonian Fluid (opens in a new tab)

  7. Computational Fluid Dynamics based redesign of the Magnetically Levitated Blood Shearing Device for Hemolysis Predictions

    Annular Couette type blood shearing devices have been used for analysis of blood damage related to device induced shear stress. Two important factors in predicting cell damage are the magnitude of stress and the duration of exposure to the stress. Several previous devices for blood damage analysis …

    rit Repository record for Computational Fluid Dynamics based redesign of the Magnetically Levitated Blood Shearing Device for Hemolysis Predictions (opens in a new tab)

  8. Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves

    … valves are related to the stress imposed on blood by the valves during the closing phase. Additionally, animal and clinical studies have shown that BMHV in the aortic position demonstrate reduced failure rates compared to identical valves in the mitral position. The present study aimed to …

    gatech Repository record for Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves (opens in a new tab)

  9. Numerical simulations of the micro flow field in the hinge region of bileaflet mechanical heart valves

    … non-physiologic hemodynamic stresses imposed on blood elements by the hinge flows. Three-dimensional characterization of the hinge flows is therefore crucial to ultimately design BMHVs with lower complication rates. This study aims at simulating the pulsatile 3D hinge flows of various BMHVs …

    gatech Repository record for Numerical simulations of the micro flow field in the hinge region of bileaflet mechanical heart valves (opens in a new tab)

  10. Shear Stress Distribution and Hemolysis Measurements in a Centrifugal Blood Pump

    … fluid dynamics (CFO) to predict red blood cell trauma (hemolysis) in blood pumps based on their exposure to turbulent stresses has increased in recent years. The U.S. Food and Drug Administration (FDA) has initiated a project to determine the fidelity with which modern CFO can …

    rit Repository record for Shear Stress Distribution and Hemolysis Measurements in a Centrifugal Blood Pump (opens in a new tab)

  11. Characterizing and Optimizing Hematologic Complications in ECMO Therapy

    … caused by abnormal shear stress and blood–device interactions. This thesis investigates how hollow fiber alignment in oxygenators influences shear stress distribution and hematologic responses to improve hemocompatibility for ECMO therapy. Computational fluid dynamics simulations …

    washington Repository record for Characterizing and Optimizing Hematologic Complications in ECMO Therapy (opens in a new tab)

  12. Development of Mechanical Cardiovascular Assist Devices for Fontan Patients: Two Novel Approaches

    … modality investigated a minimally invasive blood pump. Numerical analyses of the pump were performed to examine hydraulic performance under physiologic conditions. The pump produced pressure rises of 1 to 25 mmHg over flows of 1 to 4 LPM, has a blood damage index less than 1% and was also …

    vcu Repository record for Development of Mechanical Cardiovascular Assist Devices for Fontan Patients: Two Novel Approaches (opens in a new tab)

  13. Design of Percutaneous Dual Propeller Pump to assist Patients with Single Functional Ventricle

    … the TCPC is developed and studied. The designed blood pump is percutaneously inserted via the Femoral vein and deployed at the center of Total Cavopulmonary Connection (TCPC). The two propellers, each placed in the Superior Vena Cava (SVC) and the Inferior Vena Cava (IVC) are connected by a …

    vt Repository record for Design of Percutaneous Dual Propeller Pump to assist Patients with Single Functional Ventricle (opens in a new tab)

  14. Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics

    … systems involving superhydrophobic surfaces and blood pumps. Superhydrophobic surfaces, which can induce slip at fluid-solid interfaces, are modeled using mixed free-shear and no-slip boundary conditions. Despite remarkable effort to include the effects of surface topology and various flow and …

    oklahoma-thes Repository record for Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics (opens in a new tab)

  15. Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics

    … systems involving superhydrophobic surfaces and blood pumps. Superhydrophobic surfaces, which can induce slip at fluid-solid interfaces, are modeled using mixed free-shear and no-slip boundary conditions. Despite remarkable effort to include the effects of surface topology and various flow and …

    oklahoma-thes Repository record for Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics (opens in a new tab)

  16. Extracorporeal Circulation: Effect of Long-Term (24-Hour) Circulation on Blood Components

    Extracorporeal circulation damages blood and causes harmful side effects such as stroke and/or systemic inflammatory response in patients. Reactions of blood components to extracorporeal circulation include complement and inflammatory reactions, coagulation and thrombogenesis, frank hemolysis, and …

    vt Repository record for Extracorporeal Circulation: Effect of Long-Term (24-Hour) Circulation on Blood Components (opens in a new tab)

  17. Hemodynamic Optimization of a Passive Assist Total Cavopulmonary Connector for ages 1-20

    … The 4-way connector was intended to channel the blood flow from the inferior and superior vena cava directly to the right and left pulmonary arteries. By creating a connector with proper hemodynamic characteristics, one can control the jet flow interactions between the inferior and superior vena …

    vt Repository record for Hemodynamic Optimization of a Passive Assist Total Cavopulmonary Connector for ages 1-20 (opens in a new tab)

  18. Direct simulation of flexible particle suspensions using lattice-boltzmann equation with external boundary force

    … to the challenging problem of platelet motion in blood flow. By computing the stress distribution over the platelet, the "blood damage index" is computed and compared with experiments in channels with various geometries [43]. In platelet simulation, the effect of 3D channel geometry on the …

    gatech Repository record for Direct simulation of flexible particle suspensions using lattice-boltzmann equation with external boundary force (opens in a new tab)

  19. Shear Inducing Device for the Testing of Cell Fragility

    Most blood pumps are designed to boost the pumping abilities of the heart by mechanical energy transfer using a rotor. Due to the nature of blood contacting devices, the various components of blood are subjected to shear stresses caused by the device. The accurate analysis and prediction of blood …

    rit Repository record for Shear Inducing Device for the Testing of Cell Fragility (opens in a new tab)

Page 1 of 2