Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 32 for “"Blood Pressure Estimation"”.

  1. Cuffless Blood Pressure Estimation Using Cardiovascular Dynamics

    Blood pressure (BP) monitoring is an important tool for management of hypertension, which is a significant risk for cardiovascular disease and premature death. Since cuff-based BP measurement can be uncomfortable and does not provide continuous readings, several cuffless methods that are typically …

    ottawa-retro Repository record for Cuffless Blood Pressure Estimation Using Cardiovascular Dynamics (opens in a new tab)

  2. Blood Pressure Estimation Using Oscillometric Pulse Morphology

    … work presents the analysis of Oscillometric blood pressure pulse waveform under different pressure points (Systolic, Mean Arterial, and Diastolic Pressures). Pulse waveforms' characteristics were determined from the waveforms at three different pressures and are compared for subjects at three …

    ottawa-retro Repository record for Blood Pressure Estimation Using Oscillometric Pulse Morphology (opens in a new tab)

  3. Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation

    Blood pressure is one of the crucial vital signs that still lacks measurement accuracy in clinical environments. It is reported by physicians that automated non-invasive blood pressure measurement devices, which are usually based on the oscillometric method, do not provide accurate estimation of …

    ottawa-retro Repository record for Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation (opens in a new tab)

  4. Cuff-free blood pressure estimation using signal processing techniques

    Since blood pressure is a significant parameter to examine people's physical attributes and it is useful to indicate cardiovascular diseases, the measurement/estimation of blood pressure has gained increasing attention. The continuous, cuff-less and non-invasive blood pressure estimation is …

    sask Repository record for Cuff-free blood pressure estimation using signal processing techniques (opens in a new tab)

  5. Towards Accurate Cuffless Blood Pressure Estimation with Reduced Calibration Requirements

    Cuffless Blood Pressure (BP) estimation using Electrocardiogram (ECG) and Photoplethysmogram (PPG) features is a promising alternative to cuff-based devices for continuous BP monitoring. However, its practical deployment faces several critical challenges: Respiration Modulation (RM) introduces …

    ottawa-retro Repository record for Towards Accurate Cuffless Blood Pressure Estimation with Reduced Calibration Requirements (opens in a new tab)

  6. A Modeling Approach for Coefficient-Free Oscillometric Blood Pressure Estimation

    … most common measurement method used in automatic blood pressure (BP) monitors. However, most of the oscillometric algorithms are without physiological and theoretical foundation, and rely on empirically derived coefficients for systolic and diastolic pressure evaluation which affects the …

    ottawa-retro Repository record for A Modeling Approach for Coefficient-Free Oscillometric Blood Pressure Estimation (opens in a new tab)

  7. Improving Algorithms for Oscillometric Blood Pressure Estimation by Suppressing Breathing Effects

    Blood pressure estimation by the oscillometry is a practice growing in popularity. Algorithms for blood pressure estimation are diverse, however little effort has been put forth to assess their performance. This thesis first surveys and assesses the algorithms used for oscillometric blood pressure …

    ottawa-retro Repository record for Improving Algorithms for Oscillometric Blood Pressure Estimation by Suppressing Breathing Effects (opens in a new tab)

  8. Linear regression model for continuous non-invasive blood pressure estimation for an ICU setting

    Continuous blood pressure (BP) monitoring in critically ill patients is crucially important for clinicians. The gold standard intra-arterial method is complicated and contraindicated. Current pulse transit time (PTT)-based BP estimation methods are validated on healthy subjects using intermittent …

    uoit Repository record for Linear regression model for continuous non-invasive blood pressure estimation for an ICU setting (opens in a new tab)

  9. Deep Learning Applications in Health Informatics: Cuffless Blood Pressure Estimation and Synthetic Melanoma Image Generation

    … smartphone-based clinical applications: cuffless blood pressure monitoring from photoplethysmography (PPG) and synthetic melanoma image generation to address class imbalance in skin cancer detection. The first study introduces the Normal Blood Pressure Database (NBPDB), a curated benchmarking …

    houston Repository record for Deep Learning Applications in Health Informatics: Cuffless Blood Pressure Estimation and Synthetic Melanoma Image Generation (opens in a new tab) Embargoed until 2028-05-01

  10. An Integrated Compensation System Based on Empirical Mode Decomposition for Robust Noninvasive Blood Pressure Estimation

    … health, accuracy is not a choice. Accuracy in blood pressure (BP) estimation is essential for proper diagnosis and management of hypertension. An error of 5 mmHg is so serious, it can be responsible for doubling or halving number of patients diagnosed with hypertension. Motion artifacts are …

    ottawa-retro Repository record for An Integrated Compensation System Based on Empirical Mode Decomposition for Robust Noninvasive Blood Pressure Estimation (opens in a new tab)

  11. Blood Pressure Estimation through Photoplethysmography using Deep Learning in Clinical Setting: Critical Survey and Solutions

    Current solutions for blood pressure monitoring can be classified as invasive or non-invasive, both with drawbacks. Invasive blood pressure monitoring can lead to complications. Non-invasive blood pressure monitoring is intermittent which leads to missed episodes of hypertension and hy- potension, …

    concordia Download PDF for Blood Pressure Estimation through Photoplethysmography using Deep Learning in Clinical Setting: Critical Survey and Solutions (opens in a new tab)

  12. Non-invasive systems for out-of-clinic monitoring of biomechanical measures

    … quality output in the created wearable system. Blood pressure is a known risk factor for all cardiovascular disease, but current out-of-clinic methods require the use of an occlusive cuff which are bulky and cause discomfort. To improve user compliance, and provide a method of cuffless blood …

    gatech Repository record for Non-invasive systems for out-of-clinic monitoring of biomechanical measures (opens in a new tab)

  13. Advanced Signal Processing Solutions for Brain-Computer Interfaces: From Theory to Practice

    … a novel framework is proposed for cuff-less blood pressure estimation to be further coupled with an EEG-based BCI. Referred to as the WAKE-BPAT, the proposed framework simultaneously processes Electrocardiography (ECG) and Photoplethysmogram (PPG) signals via an adaptive Kalman filtering …

    concordia Download PDF for Advanced Signal Processing Solutions for Brain-Computer Interfaces: From Theory to Practice (opens in a new tab)

  14. Variaciones fisiológicas presentadas con la lentificación electroencefalográfica durante la hiperventilación en voluntarios sanos, Fundación Cardioinfantil

    … PO2, SaO2, pH, HCO3, base excess (BE), glycemia, blood pressure, estimation of cerebral blood flow velocity. (FSC) and pulsatility index (PI) in the middle cerebral artery (MCA), as well as electrolytes and frequency measured in Hz in the electroencephalogram (EEG); These variables were measured …

    rosario Repository record for Variaciones fisiológicas presentadas con la lentificación electroencefalográfica durante la hiperventilación en voluntarios sanos, Fundación Cardioinfantil (opens in a new tab)

  15. SYSTEM IDENTIFICATION AND DE-CONVOLUTION OF A CLASS OF MULTI-CHANNEL WAVE PROPAGATION SYSTEMS FOR UNOBTRUSIVE CARDIOVASCULAR HEALTH MONITORING

    … lies on the core idea that the central aortic blood pressure (BP) waveform can be estimated from as few as two non-invasive circulatory signals. To achieve this goal, first, we formulated a physiological model for the class of multi-channel systems with non-invasive BP measurements and …

    maryland Repository record for SYSTEM IDENTIFICATION AND DE-CONVOLUTION OF A CLASS OF MULTI-CHANNEL WAVE PROPAGATION SYSTEMS FOR UNOBTRUSIVE CARDIOVASCULAR HEALTH MONITORING (opens in a new tab)

  16. The Routine School Medical Inspection: A Study of the Efficiency of the Present Form of Examination

    … is required of the value of urine testing and blood pressure estimation as screening procedures for routine use by the service. The true role of the routine medical inspection should be decided. If its purpose is the discovery of defects then it should be planned either as a diagnostic exercise …

    glasgow Download PDF for The Routine School Medical Inspection: A Study of the Efficiency of the Present Form of Examination (opens in a new tab)

Page 1 of 2