Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"Blood Vessel Mimics"”
-
Imaging Tissue Engineered Blood Vessel Mimics with Optical Coherence Tomography
… the cellular lining within a tissue engineered blood vessel mimic (BVM). The BVM consists of two primary components. A biocompatible polymeric scaffold is used to form the tubular structure. Human microvessel cells from adipose tissue are sodded on to the inner surface of the scaffold. These …
-
Development and Characterization of Tissue Engineered Blood Vessel Mimics Under "Diabetic" Conditions
The development of tissue engineered blood vessel mimics for the testing of intravascular devices in vitro has been established in the Cal Poly tissue engineering lab. Due to the prevalence of cardiovascular disease in diabetic patients and minimal accessible studies regarding the interactions …
-
Manufacturing Silicone In-House For The Creation Of Customized Neurovascular Blood Vessel Mimics
… Obispo focuses on creating tissue-engineered Blood Vessel Mimics (BVMs) designed for the preclinical testing of neurovascular devices. These BVMs are composed of silicone models, representing anatomically accurate neurovasculatures, that are sodded with vascular cell types and then cultivated …
-
Development and Optimization of Imaging and Image Quantification Techniques for Tissue-Engineered Blood Vessel Mimics
Blood vessels mimics (BVMs) are tissue-engineered blood vessels used to test vascular devices in an environment that mimics some simple anatomical factors of native blood vessels. It is important to accurately and consistently assess tissue-engineered blood vessels, although there is currently a …
-
Development of In Vitro Tissue Engineered Blood Vessel Mimics in Complex Geometries for Coronary Stent Testing
… are implanted in coronary arteries to restore blood flow. After stent implantation, endothelial cells grow over the stent so that blood contacts the endothelial cells instead of the stent surface; this event is known as re-endothelialization. Re-endothelialization prevents blood from clotting …
-
Evaluation of Alternative Solvents for Electrospinning Occluded Scaffolds to Model Intracranial Atherosclerotic Disease in Blood Vessel Mimics
… of arteries supplying the brain, resulting in vessel narrowing, restricted blood flow, and increased risk of ischemic stroke. While various treatments exist for ICAD, most are accompanied by high recurrent stroke rates and other adverse events, highlighting the need for further investigation …
-
Novel Electrospinning Techniques for Fabricating Scaffolds to Model Intracranial Atherosclerotic Disease in Tissue Engineered Blood Vessel Mimics
… Atherosclerotic Disease in Tissue Engineered Blood Vessel Mimics Isaac “Squeaky” Buentipo Dr. Kristen Cardinal’s Tissue Engineering Lab at California Polytechnic State University specializes in fabricating customized vascular models, known as Blood Vessel Mimics (BVMs), for medical device …
-
Investigating the efficacy of a novel microfluidics-based bioprinting system to construct blood vessel mimics for tissue engineering
… and can be perfused to mimic physiological blood flow for tissue engineering purposes. The range of hollow core-shell fibres that can be generated with a defined width and geometry by changing the extrusion flow rates of core solutions, between 125-2000 μl.min–1, was demonstrated. Straight, …
-
Evaluation of Human Umbilical Vein Endothelial Cells in Blood Vessel Mimics Through Changes in Gene Expression and Caspase Activity
Blood vessel mimics (BVMs) are simple tissue engineered blood vessel constructs intended for preclinical testing of vascular devices. This thesis developed and implemented methods to characterize two of these components. The first aim of this thesis investigated the effect of cell culture duration …
-
Customization of Aneurysm Scaffold Geometries for In Vitro Tissue-Engineered Blood Vessel Mimics to Use As Models for Neurovascular Device Testing
Cerebral aneurysms occur due to the ballooning of blood vessels in the brain. Rupture of aneurysms can cause a subarachnoid hemorrhage, which, if not fatal, can cause permanent neurologic deficits. Minimally invasive neurovascular devices, such as embolization coils and flow diverters, are methods …
-
Characterizing the Reproducibility of the Properties of Electrospun Poly(D, L-Lactide-Co-Glycolide) Scaffolds for Tissue-Engineered Blood Vessel Mimics
“Blood vessel mimics” (BVMs) are tissue-engineered constructs that serve as in vitro preclinical testing models for intravascular devices. The Cal Poly Tissue Engineering lab specifically uses BVMs to test the cellular response to stent implantation. PLGA scaffolds are electrospun in-house using …
-
Development and Utilization of a Tissue Engineered Blood Vessel Mimic to Assess the Neointimal Response to Intravascular Stents
The use of intravascular stents to restore blood flow through restricted vessels in patients with coronary artery disease has become the preferred method for treating a variety of lesion locations and pathologies. As new stent configurations and coatings are developed, a great need exists for …
-
Optimizing a Quantitative Real-Time Polymerase Chain ReactionProtocol for the Characterization of Gene Expression in Blood VesselMimics
Blood vessel mimics (BVMs) are tissue engineered blood vessels that are intended as an intermediate testing environment for intravascular devices, such as stents. Specifically, Cal Poly’s Tissue Engineering Lab hypothesizes that BVMs can be used to test endothelial cell and smooth muscle cell …
-
Tissue Engineering a Blood Vessel Mimic While Monitoring Contamination Through Sterility Assurance Testing
Tissue Engineering A Blood Vessel Mimic While Monitoring Contamination Through Sterility Assurance Testing Navid Djassemi Tissue engineering blood vessel mimics has been proposed as a method to analyze the endothelial cell response to intravascular devices that are used in today’s clinical settings …
-
Evaluation of Blood Vessel Mimic Scaffold Biocompatibility
… Obispo focuses on creating tissue-engineered blood vessel mimics (BVMs) for use in preclinical testing of vascular devices. These BVMs are composed of electrospun scaffolds made of an assortment of polymers that are seeded with different cell types. This integration of polymers with cells …
-
Tissue engineered micro and macrovasculature utilizing stromal vascular fraction.
… Additionally, it is possible to create blood vessel mimics of multiple porosities in order to retain and allow cellular infiltration within the biomaterial. Chapter IV is an overall summary and conclusion of the dissertation. These studies could hopefully generate more knowledge on the …
-
Development and Evaluation of Alternative Mandrel Materials for the Fabrication of In-House Silicone Vascular Models
… San Luis Obispo develops tissue-engineered blood vessel mimics (BVMs) for preclinical testing of neurovascular devices. These BVMs are reliant on silicone vascular models that define the vessel geometry, support endothelial cell attachment, and allow devices to be evaluated in a controlled …
-
Implementation and Assessment of Hyperglycemic Conditions for the Creation of a Diabetic Blood Vessel Mimic
… diabetes mellitus) in order to maintain adequate blood glucose levels. The most severe diabetic complications arise due to hyperglycemia – a state of extremely high blood glucose levels – such as, coronary artery disease (CAD), in which coronary stent therapy is a popular method of treatment. …
-
Development of an In-Vitro Tissue Engineered Blood Vessel Mimic Using Human Large Vessel Cell Sources
… of devices and therapies. Specifically, in-vitro blood vessel mimics (BVM) have been developed to create a bench-top blood vessel model using human cells that can be used to test and evaluate vascular disease treatments and intravascular devices. Previous BVM work has used fat derived human …
-
Identifying and Reducing Variability, Improving Scaffold Morphology, and Investigating Alternative Materials for the Blood Vessel Mimic Lab Electrospinning Process
… characterization, and improvement of “Blood Vessel Mimics” (BVMs), tissue engineered constructs used to evaluate cellular response to vascular medical devices. Currently, cells are grown onto fibrous, porous tubes made using an in-house electrospinning process from PLGA, a biocompatible …