Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 90 for “"Blood flow. Measurement."”
-
Access Blood Flow Measurement Using Angiography
… to systemic circulation to carry out external blood purification by a dialyzer. To create an access, arteriovenous (AV) fistula or AV graft is predominantly used. Major problems associated with such access types include stenosis and thrombosis that affect access patency and the rate of blood …
-
Quantitative cerebral blood flow measurement with Multi Exposure Speckle Imaging
Cerebral blood flow (CBF) measures are central to the investigation of ischemic strokes, spreading depressions, functional and neuronal activation. Laser Speckle Contrast Imaging (LSCI) is an optical imaging technique that has been used to obtain CBF measures in vivo at high spatial and temporal …
-
Cerebral blood flow measurement using fMRI and pet : a validation study
… to study brain function. However, the measurements obtained with fMRI have not been rigorously validated. This thesis describes a study comparing cerebral blood flow (CBF) changes measured using a flow-sensitive alternating inversion recovery (FAIR) fMRI perfusion method, to the ones …
-
Blood flow measurement in the zebrafish heart using light sheet microscopy
… heart was mostly confined to single projection blood flow measurements or computational fluid dynamics simulations using only the information of the heart wall structure. Hence, techniques capable of direct 3D + time resolved blood flow and heart wall motion are necessary to deepen the …
-
Development of an Electromagnetic Induction Method For Non-Invasive Blood Flow Measurement
Blood flow is an important measurement in the diagnosis of cardiovascular diseases – the main cause of death globally. Cardiovascular diseases are often associated with atherosclerosis, which is a condition that causes the narrowing of arteries due to a buildup of lipids on the wall of the arterial …
-
Studies on skin blood flow measurement with particular reference to amputation level selection
… level, and the current methods for assessing blood flow are discussed. In particular, the problems which one encounters when attempting to adapt such methods into clinical practice are highlighted. Chapter 3 describes a retrospective analysis of 171 patients with peripheral vascular disease …
-
Cerebral blood flow measurement using intra-arterial bolus injection of 2H|2O monitored with magnetic resonance spectroscopy
… development of a MR-based, non-invasive cerebral blood flow (CBF) measurement method. The technique is a 3 step process: (1) Introduce a certain amount of tracer into the brain; (2) Monitor the kinetics of the tracer in the brain; (3) Fit a theoretical model to the monitored result to measure CBF. …
-
Kinetic Model Based Factor Analysis of Cardiac Rubidium-82 PET Images for Improved Accuracy of Quantitative Myocardial Blood Flow Measurement
… proper therapy. However, uniform reduction in flow throughout the heart due to disease in multiple arteries may not be detected with MPI. Myocardial blood flow (MBF) quantification using positron emission tomography (PET) can overcome this limitation, but has limited clinical application due to …
-
Modern laser speckle contrast theory: flaws and consequences
… optical imaging technique for monitoring blood flow in brain, skin, and retina. The simple and cheap instrument makes it a promising technology for both clinical applications and research. Modern LSCI theory takes advantage of the relation between blood flow and the speckle contrast v ~ …
-
Fetal Blood Flow Mapping with Magnetic Resonance Imaging
… imaging (MRI) has the potential to assess fetal blood flow. However, it faces challenges such as the small size of fetal vessels, the high fetal heart rate, uncontrolled fetal motion, limited methods to measure the fetal heart rate and the considerable complexity of the fetal circulatory system. …
-
'n Ondersoek van die hoër-dinamiese funksies van die hart by bokke en konyne
… this investigation was to use the technique of blood flow measurement in order to assess the higher dynamic functions of the heart in rabbits and goats. Rabbits and goats of different species have been used in this investigation . Parameters, for example the electrocardiogram, phonocardiogram, …
-
Development of Fourier Domain Optical Coherence Tomography for Applications in Developmental Biology
… chicken embryos, indicate a relationship between blood flow and development. It is believed that at the earliest stages, when the heart is still a tube, the purpose of blood flow is not for convective transport of oxygen, nutrients and waster, bur rather to induce shear-related gene expressions to …
-
The effect of velocity on the electrical conductivity of blood
Although the change in the conductance of blood resulting from changes in its velocity has been noted by several investigators working with electrical impedance techniques, this parameter of measurement has heretofore not been investigated from the viewpoint of practical application to blood flow …
-
Development of near infrared diffuse optics-based flowmetry for non-invasive deep tissue perfusion assessment
The continuous running of blood in the cardiovascular system is very important since it carries oxygen as well as other nutrition to support the metabolic activity of the other organs of the body. Consequently, the monitoring of blood flow becomes critical in clinical cases. For the past decades, …
Page 1 of 5