  1. Control of a rotary blood pump

    Implantable rotary blood pumps (RBPs) are an emerging technology designed to provide sufferers of heart failure with a viable treatment option which improves their medical prognosis and quality of life. The broad aim of this thesis is to address the need for a pump control strategy, and develop a …

    unsw Repository record for Control of a rotary blood pump (opens in a new tab)

  2. Characterization of cardiovascular-rotary blood pump interaction

    An implantable rotary blood pump (IRBP) is a. heart assist device used to support end-stage heart failure patients, either as a bridge to transplant or permanent support. The aim of this dissertation is to investigate the interaction between an IRBP and the cardiovascular system (CVS) using …

    unsw Repository record for Characterization of cardiovascular-rotary blood pump interaction (opens in a new tab)

  3. Microcomputer control of a pneumatic blood pump

    … of a dual chamber, diaphragm-type pneumatic blood pump in both open-loop and closed-loop modes. The open-loop mode of operation allows selection of pumping rate and systolic time parameters. The closed-loop mode of operation allows selection of pumping rate and pump output parameters, with …

    vt Repository record for Microcomputer control of a pneumatic blood pump (opens in a new tab)

  4. Miniature Axial Flow Blood Pump: Hydraulic Development & Design

    … line theory were completed to produce an initial pump geometry. Experimental testing found that mean line theory fails in pumps less than 1 cm in diameter when pumping viscous fluid. A set of 32 pumps was prototyped on a 3D printer and evaluated experimentally under steady-state conditions to …

    houston Repository record for Miniature Axial Flow Blood Pump: Hydraulic Development & Design (opens in a new tab)

  5. Hierarchical control of a two-piston toroidal blood pump

    The two-piston toroidal pump (2PTP) is a new pulsatile pumping paradigm with potential physiological advantages compared to existing continuous flow blood pump technologies. The purpose of this research was to develop hierarchical control methods for this new pumping modality, including high-level …

    texas Repository record for Hierarchical control of a two-piston toroidal blood pump (opens in a new tab)

  6. Efficiency Evaluation of a Magnetically Driven Multiple Disk Centrifugal Blood Pump

    … pressure drops and turbulent flow within the pump. Multiple disk centrifugal pumps (MDCPs) use shearing and centrifugal forces to produce laminar flow patterns and eliminate large pressure drops within the pump which greatly reduce risks that are in current VADs. The MDCP has a shaft drive …

    vcu Repository record for Efficiency Evaluation of a Magnetically Driven Multiple Disk Centrifugal Blood Pump (opens in a new tab)

  7. Shear Stress Distribution and Hemolysis Measurements in a Centrifugal Blood Pump

    … fluid dynamics (CFO) to predict red blood cell trauma (hemolysis) in blood pumps based on their exposure to turbulent stresses has increased in recent years. The U.S. Food and Drug Administration (FDA) has initiated a project to determine the fidelity with which modern CFO can …

    rit Repository record for Shear Stress Distribution and Hemolysis Measurements in a Centrifugal Blood Pump (opens in a new tab)

  8. Development of a suction detection system for a motorized pulsatile blood pump

    … The model consists of a toroidal pulsatile blood pump and a closed loop circulatory system. Together, they predict the pump's motor current traces that reflect ventricular suck-down and provide insights into torque magnitudes that the pump experiences. In addition, the model investigates …

    texas Repository record for Development of a suction detection system for a motorized pulsatile blood pump (opens in a new tab)

  9. Hybrid RANS-LES Hemolytic Power Law Modeling of the FDA Blood Pump

    … K-ω SST model to four flow conditions of the FDA blood pump. Validation of all three turbulence models show good agreement with experimental pressure and velocity fields. Evaluation of turbulent kinetic energy fields for the hybrid models show 80-90+% of kinetic energy is resolved in the rotor and …

    usf Repository record for Hybrid RANS-LES Hemolytic Power Law Modeling of the FDA Blood Pump (opens in a new tab)

  10. Modeling and control of transition dynamics in a two-piston toroidal blood pump

    … motors. A bond graph-based hybrid model of the pump is designed for better understanding of the fluid-mechanical coupling in the TORVAD, as well as performance comparison of the designed controllers. Using a simplified version of the pump model as the nominal plant, a model-based cascaded …

    texas Repository record for Modeling and control of transition dynamics in a two-piston toroidal blood pump (opens in a new tab)

  11. The potential of a tesla type device as a non pulsatile blood pump

    A review of the published work on pumps designed to assist a failing biological heart has been made and discusses the different types of pump presently on the market with the characteristics of each. The materials used to make these pumps are also discussed, together with some of the methods of …

    middlesex Download PDF for The potential of a tesla type device as a non pulsatile blood pump (opens in a new tab)

  12. Analysis of a membrane type blood oxygenator and a ventricle type blood pump

    … and in vitro analysis of the Arp Hembrane Type Blood Oxygenator and a ventricle type blood pump. The system is designed for newborns suffering from Respiratory Distress Syndrome (R.D.S.), especially the 15% who are unable to be helped by the Arp Infant Respirator. The analysis included oxygen …

    vt Repository record for Analysis of a membrane type blood oxygenator and a ventricle type blood pump (opens in a new tab)

  13. Development, Optimization, and Twisted Adjustment of an Axial Flow Blood Pump for Fontan Patients

    … A fixed-bladed impeller and diffuser for this pump was designed and optimized using ANSYS CFX™ 12.1 software. Building upon the fixed bladed geometry, a novel flexible impeller prototype was created and evaluated by hydraulic testing. In contrast to the fixed design, the flexible impeller …

    vcu Repository record for Development, Optimization, and Twisted Adjustment of an Axial Flow Blood Pump for Fontan Patients (opens in a new tab)

  14. Non-­‐Invasive Fault Detection in Axial Flow Blood Pump Used As Ventricular Assistive Device

    … Assistive Device (VAD) is a mechanical pump used to assist the functioning of a weak heart. A catastrophic obstruction in the VAD system could cost the patient their life. This thesis presents a set of fault detection techniques using the commercially available Jarvik 2000 Flowmaker® VAD …

    rit Repository record for Non-­‐Invasive Fault Detection in Axial Flow Blood Pump Used As Ventricular Assistive Device (opens in a new tab)

  15. A new blood pump and oxygenator system for support of infants with neonatal respiratory distress: preliminary in vitro and in vivo evaluation

    A clinical need exists for a blood oxygenator and pumping system for the support of neonates with respiratory deficiencies. Such systems now available for support of adults are not suitable for neonatal patients. In vitro evaluation of a new blood oxygenator and blood pumping system was performed. …

    vt Repository record for A new blood pump and oxygenator system for support of infants with neonatal respiratory distress: preliminary in vitro and in vivo evaluation (opens in a new tab)

  16. DEVELOPMENT OF A MECHANICAL CAVOPULMONARY ASSIST DEVICE FOR THE FAILING FONTAN PATIENTS

    … collapsible, percutaneously inserted, axial flow blood pump to improve blood flow in the cavopulmonary circulation. Through this research, the experimental evaluation of five blood pump prototypes and hemolysis testing of one blood pump prototype were performed. All prototypes demonstrated …

    vcu Repository record for DEVELOPMENT OF A MECHANICAL CAVOPULMONARY ASSIST DEVICE FOR THE FAILING FONTAN PATIENTS (opens in a new tab)