Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 36 for “"Blood pumps"”.

  1. A theoretical approach to the prediction of haemolysis in centrifugal blood pumps

    The successful use of centrifugal pumps as temporary cardiac assist devices strongly depends on the extent to which they damage blood. The development of a theoretical pump evaluation model was performed in this study to facilitate an effective pump optimisation. The optimisation process seeks to …

    strathclyde Repository record for A theoretical approach to the prediction of haemolysis in centrifugal blood pumps (opens in a new tab)

  2. Non-invasive modelling and control of implantable blood pumps for heart failure patients

    … by inability of the heart to supply sufficient blood-borne nutrients to meet the body’s metabolic demands. Shortage of donor organs for heart transplantation and limitations in drug therapies have led to a range of treatment alternatives for HF patients, such as implantable rotary blood pumps …

    unsw Repository record for Non-invasive modelling and control of implantable blood pumps for heart failure patients (opens in a new tab)

  3. Sensorless physiological control of implantable rotary blood pumps for heart failure patients using modern control techniques

    … for people with HF is the implantation of rotary blood pump (IRBP). In fact, an IRBP with its continuous operation requires a more complex controller to achieve basic physiological requirements. The essential control requirement of an IRBP needs to mimic the way that the heart pumps as much blood …

    unsw Repository record for Sensorless physiological control of implantable rotary blood pumps for heart failure patients using modern control techniques (opens in a new tab)

  4. Towards patient-specific modelling as a pre-operative planning strategy and follow up assessment for the treatment of advanced heart failure with rotary blood pumps

    … support (destination therapy). Rotary blood pumps (RBP) are the most popular devices in view of their size and performance. Pre-operative planning strategy for the insertion of a left ventricular assist device (LVAD) requires a timely discussion at a Multi-Disciplinary Team Meeting …

    strathclyde Repository record for Towards patient-specific modelling as a pre-operative planning strategy and follow up assessment for the treatment of advanced heart failure with rotary blood pumps (opens in a new tab)

  5. A NOVEL STRATEGY FOR CONCURRENT REDUCTION OF FLUID DRAG AND PROTEIN ADSORPTION FOR CARDIOVASCULAR MEDICAL DEVICES

    … is often known to be induced in extracorporeal blood pumps due to high rotation rates of the impeller, resulting in high shear forces that distort and ultimately destroy the blood cells. A recent proposal to address this problem is to use superhydrophobic (SHP) surface to achieve partial …

    nus Repository record for A NOVEL STRATEGY FOR CONCURRENT REDUCTION OF FLUID DRAG AND PROTEIN ADSORPTION FOR CARDIOVASCULAR MEDICAL DEVICES (opens in a new tab) Download file for A NOVEL STRATEGY FOR CONCURRENT REDUCTION OF FLUID DRAG AND PROTEIN ADSORPTION FOR CARDIOVASCULAR MEDICAL DEVICES (opens in a new tab)

  6. Resolving Flow Properties of Spiral Groove Bearings to Improve Mechanical Circulatory Support Hemocompatibility

    Rotary blood pumps are utilized as bridge to transplant, bridge to destination, and bridge to recovery devices to support a failing heart. These pumps unload the ventricles (ventricular assist devices) or replace the heart entirely (total artificial hearts), using impellers, or a rotating set of …

    rice Repository record for Resolving Flow Properties of Spiral Groove Bearings to Improve Mechanical Circulatory Support Hemocompatibility (opens in a new tab)

  7. The design, development and in vitro testing of an electric motor driven artificial heart

    The blood pumping chambers and drive pump for a totally implantable artificial heart have been developed at the biomedical engineering laboratory. The drive pump is driven by an electric motor and provides alternate pumping of the blood pumping chambers. The blood pumping chambers are diaphragm …

    vt Repository record for The design, development and in vitro testing of an electric motor driven artificial heart (opens in a new tab)

  8. Design and performance analysis of a single-drive axially-controlled miniaturized bearingless motor

    Some systems like blood pumps and equipment positioned in space stations or high towers require electrical machines with highly reliable operation and extended durability. Mechanical contact between rotating and static parts are a major cause of failure in electrical machines. To eliminate …

    brazil-uerj Repository record for Design and performance analysis of a single-drive axially-controlled miniaturized bearingless motor (opens in a new tab)

  9. Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics

    … systems involving superhydrophobic surfaces and blood pumps. Superhydrophobic surfaces, which can induce slip at fluid-solid interfaces, are modeled using mixed free-shear and no-slip boundary conditions. Despite remarkable effort to include the effects of surface topology and various flow and …

    oklahoma-thes Repository record for Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics (opens in a new tab)

  10. Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics

    … systems involving superhydrophobic surfaces and blood pumps. Superhydrophobic surfaces, which can induce slip at fluid-solid interfaces, are modeled using mixed free-shear and no-slip boundary conditions. Despite remarkable effort to include the effects of surface topology and various flow and …

    oklahoma-thes Repository record for Investigation of Flow through Complicated Microfluidic Devices and over Micropatterned Surfaces using Computational Fluid Dynamics (opens in a new tab)

  11. Extracorporeal Circulation: Effect of Long-Term (24-Hour) Circulation on Blood Components

    Extracorporeal circulation damages blood and causes harmful side effects such as stroke and/or systemic inflammatory response in patients. Reactions of blood components to extracorporeal circulation include complement and inflammatory reactions, coagulation and thrombogenesis, frank hemolysis, and …

    vt Repository record for Extracorporeal Circulation: Effect of Long-Term (24-Hour) Circulation on Blood Components (opens in a new tab)

  12. Design of hygienic blood collection system for poultry slaughterhouses

    Blood collection methods from poultry slaughterhouses are assessed and designed. Specifically, a hygienic method to collect blood with no solid debris has been investigated. The research involved designing, improving and/or selecting the blood collection troughs, pipelines, valves, blood pumps, …

    regina Repository record for Design of hygienic blood collection system for poultry slaughterhouses (opens in a new tab) Download PDF for Design of hygienic blood collection system for poultry slaughterhouses (opens in a new tab)

  13. Simulation of Aortic Valve Dynamics during Left Ventricular Support

    Implantable Rotary Blood Pumps (IRBPs) for the left ventricle (LV) have become a viable treatment and long-term option for heart failure (HF) patients. In addition, development of valve abnormalities after Left Ventricular Assist Device (LVAD) implantation is common among patients with advanced HF, …

    unsw Repository record for Simulation of Aortic Valve Dynamics during Left Ventricular Support (opens in a new tab)

  14. Shear Inducing Device for the Testing of Cell Fragility

    Most blood pumps are designed to boost the pumping abilities of the heart by mechanical energy transfer using a rotor. Due to the nature of blood contacting devices, the various components of blood are subjected to shear stresses caused by the device. The accurate analysis and prediction of blood …

    rit Repository record for Shear Inducing Device for the Testing of Cell Fragility (opens in a new tab)

  15. Characterization of Shear-Induced Hemolysis in Rotational Medical Devices

    … for a large variety of heart ailments. These blood pumps necessarily exert some degree of shear stress on blood passing through them, which, over time, may cause the rupture of red blood cells, coagulation, thromboses, and bleeding. This limits their use as long term treatment and therapy. …

    rit Repository record for Characterization of Shear-Induced Hemolysis in Rotational Medical Devices (opens in a new tab)

  16. The potential of a tesla type device as a non pulsatile blood pump

    A review of the published work on pumps designed to assist a failing biological heart has been made and discusses the different types of pump presently on the market with the characteristics of each. The materials used to make these pumps are also discussed, together with some of the methods of …

    middlesex Download PDF for The potential of a tesla type device as a non pulsatile blood pump (opens in a new tab)

  17. Enhancing Flow-Related Haemocompatibility in Mechanical Circulatory Support: Computational and Experimental Approaches

    … alternative treatments. Fully implantable pumps to support the heart, known as ventricular assist devices (VADs), have thus gained importance as long-term treatment options. Although outcomes of treatment with VADs have greatly improved, their use is still associated with higher …

    zurich

  18. Computational hemodynamics: Hemolysis and viscoelasticity

    … and reliable design tool for the analysis of blood-handling devices. The CFD-based design is simple, time- and cost-effective; the method predicts accurately the hydraulic performance of these devices. However, the CFD-based hematologic design is in its infancy. This thesis presents a holistic …

    rice Repository record for Computational hemodynamics: Hemolysis and viscoelasticity (opens in a new tab)

  19. Analysis and experiments on flow-induced hemolysis.

    … stresses in flows within hypodermic needles, blood pumps, artificial hearts and other cardiovascular devices, is one of the major concerns during the design and use of cardiovascular or blood-processing extracorporeal devices. A non-invasive experimental method which does not interfere …

    louisville Repository record for Analysis and experiments on flow-induced hemolysis. (opens in a new tab)

Page 1 of 2