Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 26 for “"Bold contrast"”.
-
Expanding the role of functional mri in rehabilitation research
… based on blood oxygenation level dependent (BOLD) contrast has become a universal methodology in functional neuroimaging. However, the BOLD signal consists of a mix of physiological parameters and has relatively poor reproducibility. As fMRI becomes a prominent research tool for …
-
Hemodynamic measurements and modeling for functional magnetic resonance imaging
… is the physical mechanism that ultimately yields contrast in the fMRI signal. This is known as Blood-Oxygen Level Dependent (BOLD) contrast. A critical piece of information in this process, hemodynamics, is the dynamics of cerebral (brain) oxygen concentrations in relation to blood flow. The …
-
Evaluation of clinical functional magnetic resonance imaging (fMRI) applications within the mesial temporal lobe
… of fMRI in a clinical context is the low BOLD contrast in individual subjects, especially within MTL, where the SNR is genuinely low. Because caffeine has recently been proposed as an effective BOLD contrast booster in functional MRI studies for studies confronted with a low SNR (Mulderink …
-
On the Mapping of Cortical Columns in Humans Using High-Resolution Functional Magnetic Resonance Imaging
… of the blood oxygenation level dependent (BOLD) contrast exploited by fMRI, the spatial point spread function (PSF) of the gradient echo (GE) and the spin echo (SE) BOLD signal tangential to the cortical surface was determined at different cortical depths. Both GE- and SE-BOLD showed a loss …
-
Examination of susceptibility effects on functional and dynamic magnetic resonance imaging
… magnetic field inhomogeneity also drives certain contrast mechanisms including blood oxygenation level dependent fMRI. The two projects in this work look at the effects of inhomogeneity on functional and dynamic MRI. We simultaneously acquired functional and dynamic MRI (Simulscan) of natural …
-
Applicability of Quantitative Functional MRI Techniques for Studies of Brain Function at Ultra-High Magnetic Field
… uses the blood oxygenation level dependent (BOLD) contrast to detect functionally induced changes in the oxy-deoxyhaemoglobin composition of blood which reflect cerebral neural activity. As these blood oxygenation changes do not only occur at the activation site but also downstream in the …
-
Propeller Development Process: Conflict and Cooperation Between the Department of Defense and Civil Aviation
<p>The purpose of this thesis was to compare and contrast the acquisition of the Electronic Propeller Control System through both the Department of Defense and Civil Aviation processes controlled by the Federal Aviation Administration (FAA). The author was a planner and participant in the …
-
Characterization and compensation of physiological fluctuations in functional magnetic resonance imaging
… based on blood oxygenation level dependent (BOLD) contrast has become a widespread technique in brain research. The central challenge in fMRI is the detection of relatively small activity-induced signal changes in the presence of various other signal fluctuations. Physiological fluctuations …
-
Εγκεφαλική λειτουργική απεικόνιση μηχανισμών λειτουργίας αντιγραφής προτύπων
… use of functional magnetic resonance imaging (BOLD contrast). The data was analysed after appropriate pre-processing with the use of analysis of variance and the multivariate statistical method of multidimensional scaling (MDS). Results: Clear prominence of the “dominant” hemisphere in what …
-
Active Staining for In Vivo Magnetic Resonance Microscopy of the Mouse Brain
… images. To address this problem, T1-shortening contrast agents can be used, which not only improve the tissue contrast-to-noise ratio (CNR) but also increase SNR by allowing the MR signal to recover faster between pulses. By "actively staining" the tissue with these T1-shortening agents, MRM can …
-
Quality assurance in modern techniques of functional Magnetic Resonance Imaging (fMRI) based on BOLD using special anthropomorphic phantoms: applications in the stimulation of the motor and visual cerebral cortex
… such as functional MRI (f MRI) which depends on BOLD(Blood Oxygen Level Dependant) contrast. The results of BOLD measurements rely on statistical analysis of the acquired signal and are sensitive to noise, SNR and even the examination conditions of the patientwith the use of stimulation devices. …
-
Modified-cs-residual for Recursive Reconstruction of Highly Undersampled Functional MRI Sequences
… types of blood oxygenation level dependence (BOLD) contrast signals. As a result, our proposed modified-CS-residual can causally reconstruct fMRI sequences and significantly reduce the image acquisition time to enable higher spatial and temporal resolution, which is of great practical use in …
-
Improving Data Quality for Functional Magnetic Resonance Imaging
… based on the blood oxygen level dependent (BOLD) contrast. It is widely used in neuroscience research and, to a more limited extent, clinically for neurosurgical planning. A stimulus or task is conventionally used to evoke brain activity; however, functional connections in the brain can also …
-
Sparse Recovery with Partial Support and Signal Value Knowledge and Applications in Dynamic MRI
… for blood oxygenation level dependent (BOLD) contrast functional MR imaging (fMRI). In particular, we show, via exhaustive experiments on actual MR scanner data for brain fMRI, that our recently proposed approach for recursive reconstruction of sparse signal sequences, modified-</p> …
-
Depth-Dependent Physiological Modulators of the BOLD Response in the Human Motor Cortex
… imaging (fMRI). Blood oxygen level dependent (BOLD) fMRI estabilished itself as the most frequently used technique for mapping brain activity in humans. It is non-invasive and allows to obtain information about brain oxygenation changes in a few minutes. It was discovered in 1990 and, since …
-
Inhaled Oxygen as a Quantitative Intravascular MRI Contrast Agent
… fraction of inspired oxygen (FiO2) generates MR contrast by two distinct mechanisms: increased T2 from deoxyhemoglobin dilution in venous compartments (blood oxygenation level-dependent effect or BOLD) and reduced T1 from paramagnetic molecular oxygen dissolved in blood plasma and tissues. Many …
-
Characterizing the Effects of Sub-Concussive Head Impacts on Brain Biomarkers: a Multi-Modal Approach Toward Developing Safer Practices on the Football Field
… using the blood oxygenation level dependent (BOLD) contrast has limited our understanding for the effects of repetitive head impacts on physiological parameters such as cerebral blood flow (CBF), cerebrovascular reactivity (CVR) and cerebral metabolic rate of oxygen consumption (CMRO2). In …
-
Spatiotemporal dynamics of low frequency fluctuations in bold fMRI
… fMRI utilizes blood oxygenation level dependent (BOLD) contrast to map brain activity. BOLD signal is sensitive to the hemodynamic changes associated with brain activity, and gives an indirect measure of brain activity. Low frequency fluctuations (LFFs) have been observed in the BOLD signal even …
-
Methodological Aspects of Clinical fMRI - Reliability Assessment and Development of Data Analysis Strategies
… to the blood oxygenation level dependent (BOLD) contrast. Theoretical expressions for the calculation of the BOLD sensitivity were verified and improved. The BOLD sensitivity was investigated in a group of healthy volunteers using a clinical magnetic resonance imaging (MRI) system, and it …
-
Nahinfrarotspektroskopie und funktionelle Magnet-Resonanz-Tomographie: simultaner Ansatz bei motorischer Einzelstimulation
… mit Blood-Oxygen-Level-Dependent- (BOLD-) Kontrast- sensitiven Sequenzen durchgeführt. Ergebnisse: Die einzelne schnellende Fingerbewegung, durch Tastendruck registriert, ist in der Lage, eine ausreichend starke neurovaskuläre Antwort hervorzurufen, die eine lateralisierte …
Page 1 of 2