Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 117 for “"Bolometer"”.
-
First Development and Demonstration of Fiber Optic Bolometer
<p>The fiber optic bolometer (FOB) was demonstrated observing a fusion plasma for the first time, and 2D fiber optic bolometer was developed and demonstrated to have high spatial resolution. The FOB is a novel type of a bolometer that is theoretically immune to EMI. A bolometer that is a sensor …
-
Design and optimization of a YBCO based superconducting bolometer
L'abstract è presente nell'allegato / the abstract is in the attachment
-
Development of superconducting bolometer device technology for millimeter-wave cosmology instruments
<p>The Cold-Electron Bolometer (CEB) is a sensitive detector of millimeter-wave radiation, in which tunnel junctions are used as temperature sensors of a nanoscale normal metal strip absorber. The absorber is fed by an antenna via two Superconductor-Insulator-Normal metal (SIN) tunnel junctions, …
-
Calibration of a germanium bolometer for use in cold-background radiometric testing
<p>A germanium bolometer has been obtained and evaluated for possible use in radiometric testing. The instrument and test procedures are described, and results are presented which detail the bolometer's response to a variety of operating conditions. Suggested improvements to the bolometer and the …
-
Development of fiber-optic bolometer based on a silicon fabry-perot interferometer
In magnetically confined fusion (MCF), resistive bolometers are conventionally used for the detection of the plasma radiation helping to understand heat exhaust scenarios. However, the performance of resistive bolometer experiences unavoidable degradation in the practical applications due to the …
-
Extra-galactic and survey science with the submillimeter common user bolometer array-2
We have carried out a pilot study for the SCUBA-2 'All-Sky' Survey, SASSy, a wide and shallow mapping project at 850 μm, designed to find rare objects, both Galactic and extragalactic. Two distinct sets of exploratory observations were undertaken, and used to test the SASSy approach and data …
-
Aspects of Bi₂Sr₂Ca₂Cu₃O on silicon bolometer fabrication and operation
… production of a Bi₂Sr₂Ca₂Cu₃Oy superconducting bolometer was done. An analysis of the noise performance of Bi₂Sr₂Ca₂Cu₃Oy thin films was done with particular attention to the character and magnitude of 1/f noise in the material. Deposition of Bi₂Sr₂Ca₂Cu₃Oy onto a silicon substrate was attempted …
-
Room Temperature VOx Air-Bridge Bolometer integrated with Metal-Insulator-Metal Resonant Absorbers
Spectrally-selective un-cooled micro-bolometers have many military and industrial applications for infrared sensing and imaging, e.g. target acquisition and chemical analysis. In this work, a micro-bolometer was fabricated with integrated wavelength-selective absorber based on subwavelength …
-
Optical analysis of the ERBE scanning thermistor bolometer radiometer using the Monte Carlo method
… active cavity and scanning thermistor bolometer radiometers are orbiting the Earth to monitor its radiative emission. A numerical model has been formulated to better understand the performance of the ERBE scanning radiometer and to aid future radiometric design and calibration …
-
A numerical study of equivalence in scanning thermistor bolometer radiometers for earth radiation budget applications
… and equivalence of the ERBE scanning thermistor bolometer radiometers. The finite-difference method is applied to the detector of the ERBE scanning radiometer to characterize its thermal and electrical dynamic behavior. The thermal analysis confirms the thermal time constant of the instrument …
-
FIBER-OPTIC SILICON FABRY-PEROT INTERFEROMETERS FOR HIGH-SPEED ANEMOMETER AND HIGH-SENSITIVITY BOLOMETER APPLICATIONS
… and characterization of a fiber-optic bolometer (FOB) with improved noise equivalent power density (NEPD) performance and increased absorption to high energy photons by engineering the absorber of the FOB. We also have developed a multichannel fiberoptic bolometry system with five …
-
A THz focal plane imaging array using metamaterial-inspired bolometer and wafer-level integrated focusing elements
… arrays such as Schottky diode rectifiers and bolometers. A typical focal plane array (FPA) pixel element consists of a read-out circuitry, detector device and an antenna or a lens element. A 100×100 element FPA will require 10,000 of these individual elements. Pick-and-place of such a large …
-
Ultrasensitive Superconducting Cold-Electron Bolometer Coupled to Multi-frequency Phased Antenna Array for Polarization Detection of the Cosmic Microwave Background
… problems. This will also enable us to realize bolometer arrays with thousands of pixels needed to meet the sensitivity requirements of future CMB polarization experiments and to achieve better resolutions and higher scan speeds. Having multiple frequencies is important to differentiate the CMB …
-
Cold-Electron Bolometers
… thesis concerns the fabrication of Cold-Electron Bolometers (CEBs) with shadow angle evaporation technique, suitable for measuring the Cosmic Microwave Background Radiation as a part of the BOOMERanG project. We have studied two possible improvements of the absorber. Firstly, we have decreased the …
-
Sensitivity of the CUPID Experiment to Bragg-Primakoff Conversion of Solar Axions and ALPs
… on the application of a technique to use bolometer detector arrays, such as those of the CUORE experiment and its proposed upgrade CUPID, to search for 14.4 keV Solar axions arising from an M1 nuclear transition of thermally excited 57Fe in the Solar core. Density functional theory …
-
PSICE modelling and parametric study of microbolometer thermal detectors
The operation of a bolometer thermal sensor is analogous to that of a charging capacitor in a generic RC circuit. As such, circuits containing bolometers can be analyzed with standard circuit simulation programs such as PSPICE. This thesis deals with the development of a bolometer model by using …
-
Bolometric detectors for EBEX: a balloon-borne cosmic microwave background polarimeter.
… and performance of arrays of millimeter-wave, bolometeric detectors for EBEX, the E and B Experiment. EBEX is a balloon-borne telescope designed to measure the polarization in the cosmic microwave background (CMB) radiation with 8 arc-minute resolution at 150, 250 and 410 GHz during a 14-day …
-
Astronomical submillimetre Fourier transform spectroscopy from the Herschel Space Observatory and the JCMT
… One, SPIRE, comprises a FTS paired with bolometer detector arrays. SCUBA-2 (Submillimetre Common User Bolometer Array) and FTS-2 have recently been commissioned and will be mounted within the collecting dish of the James Clerk Maxwell Telescope by Fall, 2010. The use of FTS in these two …
Page 1 of 6