Showing 1 to 17 of 17 for “"Bolt shear"”.
-
The Static and Fatigue Behaviour of Through-Bolt Shear Connectors in Steel-Precast Composite Bridge Girders
… connected to steel girders using mechanical shear connectors is one form of accelerated bridge construction where the major components can be fabricated off-site. Employing modular bridge components takes advantage of improved quality and efficient construction through prefabrication, …
-
Nonlinear Finite Element Analysis of Reinforced Concrete Slab-Column Connections with Headed Stud/Bolt Shear Reinforcement Subjected to Punching Shear
… flat slabs supported on columns with headed stud/bolt shear reinforcement, there are still many parameters which have not been adequately studied in the laboratory due to cost or time constraints. As a result much of the current code provisions for designing slab-column connections against …
-
Finite Element Analysis of Single Plate Shear Connections
… have been several design models for single plate shear connections in the past 20 years. The current design model states that the bolt shear rupture strength of a connection is a function of the number of bolts and the a-distance, which is the distance from the weld line to the bolt line. The …
-
An Experimental Investigation into the Effect of Clearance and Torque on Load Sharing in a Bolted Joint
The shear load experienced by each bolt in a multi-fastener bolted butt joint is a percentage of the total load applied to the joint. Joint failure can be premature when one fastener is subjected to a disproportional amount of the total load. Conversely, the ultimate load the joint can endure may …
-
The Fatigue Behaviour of Welded and Bolted Shear Connectors in Composite Highway Bridges
… case of steel-concrete composite bridges, the shear connection between the concrete deck and the steel girders is a vital element of the bridge system, and has significant impacts on construction time, cost, structural integrity, and durability. The general performance of the shear connectors …
-
An experimental parametric study on the efficiency of hybrid fastening system
… advancements in joining systems are necessary. Bolted joints are a common method used due to the simplicity of the process. Drilling holes in composites for fastening results in delamination, creation of locations for the onset of failure, and can reduce load-carrying capacities. Hybrid …
-
Strength and Reliability of Bolted Connections Susceptible to Tearout
… of tearout can complicate the design of steel bolted connections since, in contrast to the limit states of bearing and bolt shear rupture, tearout strength can vary from bolt to bolt within a connection. Under the current AISC Specification, tearout strength is proportional to the clear …
-
Experimental Evaluation of Tearout in Eccentrically Loaded Bolt Groups
… can limit the strength of eccentrically loaded bolt groups. A common approach to design eccentrically loaded bolt groups is the instantaneous center of rotation (IC) method. This method has been validated against test results of specimens failing in bolt shear, bearing, or slip, where all the …
-
Structural Behavior of Lap Shear Connections with Thermally Insulating Filler Plates
… (RCSC 2014) suggests a reduction in the bolt shear strength when undeveloped fillers with a thickness of more than 0.25 inch are used while using any non-steel material is prohibited due the limited research available. Most research studies have investigated the mechanical behavior of …
-
Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates
… examined the influence of fuse plate geometry, bolt configuration, and buckling-restraints on strength, ductility, and deformation capacity. Results indicated that the buckling-restraint washers and bolts were effective at preventing out-of-plane buckling. Specimen M1.5 was successful in meeting …
-
Loads on Tie-Down Systems for Floating Drilling Rigs during Hurricane Conditions
… footings. The capacities of the clamps in slip, bolt tension, and bolt shear can be also analyzed using the resultant data to provide guidance on appropriate design values.
-
Connector development for hybrid masonry seismic structural systems
… the steel frame of a building and the masonry shear wall as well as the development of specific detailing requirements to provide for a ductile and somewhat predictable response in a seismic event of significant magnitude. The scope of this thesis is the investigation of the connection between …
-
Behavior of bolted connections during and after a fire
… temperature must be understood. Floor beams and bolted connections were studied with both experimental and analytical methods in this research program, which provide useful information on the strength of bolted connection at elevated temperature. Shear strength of A325 and A490 high strength …
-
Through bolt connections for composite columns
… issue, mainly because the transfer of the beam shear to an axial load in the concrete core is not well understood. Friction is often relied upon to transfer loads although some design codes require direct bearing on the concrete. The development of an inexpensive connection which bears directly …
-
Two-dimensional numerical simulation and design of fully grouted bolts for underground coal mines.
The fully grouted bolt is a passive support. It occupied the greatest portion of the annual roof bolt consumption in the U.S. There are three components of the fully grouted bolt; steel rebar (bolt), resin annulus, and rock/grout interaction. Fully grouted bolts are loaded in three ways: axial …
-
Experimental methods for understanding the behavior and residual capacity of bolts and steel bolted connections under impulsive loads
… A more thorough understanding of the behavior of bolted steel connections during and after extreme loading events is necessary to be able to predict and prevent progressive collapse of the structures. Connections ensure ductility and transfer loads to surviving structural elements after an extreme …
-
The behaviour of steel fin plate connections in fire
… of moment and tying forces, as well as vertical shear forces, and the real behaviour, even of nominally pinned connections, can have a significant effect on the overall response of the frame. To date very little information on the behaviour and the resistance of simple shear connections in fire …