Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"Bone Stiffness"”.
-
Validating Internal Density Calibration in The Proximal Humerus to Estimate Bone Stiffness Using Finite Element Analysis for Stemless Shoulder Arthroplasty
… osteoarthritis (OA). OA is known to alter bone density in the humeral head, which can compromise implant stability and increase the need for surgical revisions. Current pre-operative clinical assessments are limited in evaluating bone mineral density (BMD) and fail to consider the …
-
Stiffness of the Proximal Tibial Bone in Normal and Osteoarthritic Conditions: A Parametric Finite Element Simulation Study
… joint disease marked by cartilage and bone changes. Morphological and mechanical changes to bone, which are thought to increase overall bone stiffness, result in distorted joint mechanics and accelerated cartilage degeneration. Using a parametric finite element (FE) model of the …
-
Biomechanical Measures of the Muscle-Bone Unit in Postmenopausal Females: A Pilot Study
Bone is a dynamic tissue that adapts its stiffness and strength to the habitual loading environment. Muscles attach to bone and the largest loads experienced by bone come from voluntary muscle contractions. The objective of this study was to quantify the relationship between functional measures of …
-
Probabilistic finite element analysis of the uncemented total hip replacement
… total hip replacement (UTHR). The implant and bone stiffness, load magnitude and geometry, and implant version angle were included as random variables and a reliable strain-based performance indicator was adopted. The sensitivity results highlighted the bone stiffness, implant version and load …
-
Using HR-pQCT and finite element analysis to inform clinical assessment of distal radius fractures
… allows for non-invasive in vivo assessment of bone density and stiffness throughout the fracture healing process, which may inform fracture healing progression and cast removal. Many fracture assessment instruments have been developed for clinical use, but a lack of validation and …
-
Development of a non-invasive imaging technique for characterizing subchondral bone density and stiffness
Osteoarthritic (OA) subchondral bone is marked by mechanical and morphological alterations which are thought to influence cartilage integrity, leading to degeneration. The exact role of subchondral bone in OA etiology is, however, unclear and much of our understanding of OA-related subchondral bone …
-
ADDRESSING PARTIAL VOLUME ARTIFACTS WITH QUANTITATIVE COMPUTED TOMOGRAPHY-BASED FINITE ELEMENT MODELING OF THE HUMAN PROXIMAL TIBIA
… has potential to clarify the role of subchondral bone stiffness in osteoarthritis. The limited spatial resolution of clinical CT systems, however, results in partial volume (PV) artifacts and low contrast between the cortical and trabecular bone, which adversely affect the accuracy of QCT-FE …
-
Mapping Anisotropy of the Proximal Femur for Improved Image-Based Finite Element Analysis
Finite element (FE) models of bone derived from clinical quantitative computed tomography (QCT) rely on realistic material properties to accurately predict patient-specific bone strength in vivo. QCT cannot resolve microarchitecture, therefore QCT-based FE models lack the directionality apparent …
-
FINITE ELEMENT ANALYSIS OF THE HIERARCHICAL STRUCTURE OF HUMAN BONE
… of the basic hierarchical structure of the human bone. The model computed the stiffness of composite collagen fibers comprised of collagen fibrils and hydroxyapatite mineral crystals. Next, the stiffness of the concentric lamella was computed utilizing the stiffness of the collagen fibers and …
-
An experimental study of the effect of bone inorganic-organic composition on the mechanical properties
Bone is a living composite material consisting of inorganic minerals, organic proteins, and water, which approximately account for 60%, 30% and 10% of bone mass, respec-tively. In the reported experimental studies on bone mechanical properties, attention has been focused on the effect of inorganic …
-
Vascular and Mechanical Changes in Bone in Response to Chronic Ischemia and Mechanical Loading
… of ischemia and mechanical stimulation on bone remodeling. An immunohistochemistry protocol for vessel marking in bone was also developed. Ischemia was induced in a mouse model to determine vascular and mechanical property changes in bone in response to hypoxia, and mechanical …
-
TransVNet: Predicting bone degradation using ViT and virtual dataset of cellular microstructures
Degradation of bone, especially for astronauts exposed to microgravity conditions, is crucial for space exploration missions since the lower applied external forces accelerate the diminution in bone stiffness and strength substantially. Even though existing computational models and simulations help …
-
Characterization of bone structural, geometric, and material properties in the TallyHO mouse model of type 2 diabetes mellitus
… without T2DM despite having comparable to higher bone mineral density (BMD). Thus, T2DM might alter other aspects of resistance to fracture beyond BMD such as bone geometry, microarchitecture, and tissue material properties. In this study, we characterized the skeletal phenotype of the TallyHO …
-
Das ovariektomierte und glukokortikoid-behandelte Schaf als Großtiermodell für die Osteoporoseforschung
… methods were used to quantify changes in ovine bone under estrogen-deficiency and glucocorticoid treatment. With DXA we monitored the progression of the loss of bone mineral density of integral bone at the central and the load-bearing skeleton. Peripheral QCT was employed to determine the …
-
Finite element analysis of a cementless proximal femoral stem in relation to early stem stability and interface bone strain
… assessing stems stability using only one femoral bone property was tested by varying the bone properties systematically and examining the resultant stem stability and interface strain. Unlike previous published studies which looked at the micromotion values only, the interface strains were also …
-
Multiscale characterisation of subchondral trabecular bone changes in the osteoarthritic ankle
… to the success of the device, as well as low bone stock at revision. Changes to subchondral bone with osteoarthritis is well studied in the hip and knee, but the ankle remains highly under-reported. Medical imaging and validated computational modelling can provide predictive capabilities of …
-
Mechanical Response Tissue Analysis: Inter- and Intra-trial Reliability in Assessing Bending Stiffness of the Human Tibia in College Aged Women
… technology for assessing maximal bending stiffness (EI) of human long bones in vivo. The MRTA variable, EI, is the product of Young's modulus of elasticity (E) and cross-sectional moment of inertia (I). EI quantifies material and architectural/geometric properties of bone. Published human …
-
Implant Stiffness and Peri-Prosthetic Bone Changes in the Rat Model
Clinically, decreased bone content surrounding implants, renewed pain and implant loosening lead to revision surgeries following fracture fixation and joint replacement. A key reason for this phenomenon is stress shielding by Wolff’s law where the high stiffness of the implant materials used …
-
Bone Microstructure and Bone Strength at the Distal Radius In Relation to the Pubertal Growth Spurt in Adolescence
… spurt is well documented but it is unclear if bone structure is weaker during this rapid period of growth. The objectives of this research are to 1) determine the precision errors (CV%RMS) for bone strength outcomes under specific loading conditions, and 2) compare bone strength and …
-
The Effects of Impact Loading on the Equine Metacarpophalangeal Joint
… first phalanx (P1) and proximal sesamoid (PS) bones and 3) finite element (FE) analysis to compare the stress distributions in the distal MC3 of healthy and diseased (osteoarthritic - OA) MCP equine joints under impact and static loading. Results: Signal energy reaching MC3 was significant at …
Page 1 of 2