Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 199 for “"Bone implant"”

  1. Development of a prevascularized bone implant

    … mechanical structure of the body and consists of bone, which is hard connective tissue. The tasks the skeleton and bones take over are of mechanical, metabolic and synthetic nature. Lastly, bones enable the production of blood cells by housing the bone marrow. Bone has a scarless self-healing …

    wurz-thes Repository record for Development of a prevascularized bone implant (opens in a new tab)

  2. Biomechanical characterisation of the bone-implant interface

    Les interventions chirurgicales impliquant des implants orthopédiques ou dentaires échouent encore souvent pour des raisons liées à un manque de stabilité. Pendant la phase de cicatrisation suivant la chirurgie, du tissu osseux se forme et se remodèle directement à la surface de l'implant grâce au …

    star-france Repository record for Biomechanical characterisation of the bone-implant interface (opens in a new tab)

  3. Ultrasonic characterization of the bone-implant interface

    … routinier des interventions chirurgicales en implantologie, les risques d'échecs subsistent et peuvent être lourds de conséquences. L'issue clinique est directement liée au processus d'ostéointégration, qui correspond à la repousse osseuse au contact direct de l'implant. Ce travail porte sur …

    star-france Repository record for Ultrasonic characterization of the bone-implant interface (opens in a new tab)

  4. Flexible Screw Design for Bone Implant Application

    … has been proposed. However, subsequent carpal bone loss is an inherent risk to this technique. The goal of this study was to design a flexible orthopedic screw that can be placed between the scaphoid and lunate to restore more normal biomechanics without the risk of osteolysis. Several ideas …

    vcu Repository record for Flexible Screw Design for Bone Implant Application (opens in a new tab)

  5. Multi-Dimensional Characterization of Bone and Bone-Implant Interfaces

    Metallic bone implant devices are commonly used to tackle a wide array of bone failures in human patients. The success of such implants relies on the biomechanical and functional bonding between the living bone tissue and implant, a process defined as osseointegration. However, the mechanism of …

    mcmaster Repository record for Multi-Dimensional Characterization of Bone and Bone-Implant Interfaces (opens in a new tab)

  6. Finite element study of a shape memory alloy bone implant

    … for biomedical devices.Osteoporosis is a common bone disease especially in elderly people. Bone degradation as the result of osteoporosis causes loosing of screws implanted in the bone during or after surgery. A new nitinol-based device which is designed to mitigate this adverse effect has been …

    ohiolink Repository record for Finite element study of a shape memory alloy bone implant (opens in a new tab)

  7. Evaluation of a fluorapatite-spinel ceramic as a bone implant

    … a ceramic that can be used as a hard tissue implant. After investigation of several mixtures of tricalcium phosphate, calcium fluoride, magnesium carbonate and alumina, a composite of fluorapatite and spinel was selected as the ceramic material. The ability to prepare sound samples and the …

    iastate Repository record for Evaluation of a fluorapatite-spinel ceramic as a bone implant (opens in a new tab)

  8. Numerical modeling of the adhesive contact at the bone-implant interface

    Les implants osseux constituent actuellement l'approche thérapeutique la plus utilisée pour les réparer les articulations et les os endommagés. La stabilité initiale est obtenue pendant la chirurgie grâce à un processus d'ajustement serré dans l'os hôte, tandis que la stabilité à long terme est …

    star-france Repository record for Numerical modeling of the adhesive contact at the bone-implant interface (opens in a new tab)

  9. Selective Laser Melting of Porosity Graded Gyroids for Bone Implant Applications

    … alloy (Ti6Al4V) gyroid lattice structures for bone implant applications. First, A MATLAB® code was developed to create various gyroid designs and understand the relationship between the implicit equation parameters and the measurable outputs of gyroid unit cells. A novel gyroid lattice …

    mcmaster Repository record for Selective Laser Melting of Porosity Graded Gyroids for Bone Implant Applications (opens in a new tab)

  10. Mechanobiological Regulation of Hard Tissues: From Tooth Formation to Bone Implant Design

    Hard tissues such as bone and teeth are regulated by mechanical stimuli throughout their entire life cycle, spanning initial formation, functional adaptation, and long-term self-renewal. This concept, rooted in Wolff's law, provides a unifying mechanobiological framework for understanding both …

    tamu Repository record for Mechanobiological Regulation of Hard Tissues: From Tooth Formation to Bone Implant Design (opens in a new tab) Embargoed until 2028-05-01

  11. Sealing the bone-implant interface around total hip replacements using guided bone regeneration.

    … seal, which would become incorporated by bone and soft tissue, forming a secondary biological seal. The hypothesis was that these physical and biological seals, would prevent the debris from accessing the interfacial tissues where they cause bone loss and implant loosening. The …

    ucl Repository record for Sealing the bone-implant interface around total hip replacements using guided bone regeneration. (opens in a new tab)

  12. Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components

    … Currently, the newer generation of TAA implants rely on primary and secondary fixation, in which primary fixation is obtained through mechanical fixation immediately post-operative and secondary fixation is achieved through bone ingrowth at the bone-implant interface. To promote bone …

    queens Repository record for Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components (opens in a new tab)

  13. Histological and Mechanical Analysis of Bone/Implant Interface in Female Retired-Breeder Rabbits

    Endosseous implants have been accepted as a viable dental and medical adjunct and are now used for multiple dental applications. The majority are placed in patients of relatively advanced age, and, as such, the increased use of implants has raised questions in the areas of bone healing and …

    iupui Repository record for Histological and Mechanical Analysis of Bone/Implant Interface in Female Retired-Breeder Rabbits (opens in a new tab)

  14. Fabrication and corrosion assessment of biodegradable metallic alloys for patient-specific bone implant applications

    … dissolve after their service lifetime. Permanent implants are often much stiffer than the bone they are supporting, which can lead to loss of bone density, mechanical failure of the implant, and require corrective surgery. Biodegradable orthopedic implants offer strength and stiffness close to …

    utc Repository record for Fabrication and corrosion assessment of biodegradable metallic alloys for patient-specific bone implant applications (opens in a new tab)

  15. Osteocytes as indicators of bone quality - multiscale structure-composition characterisation of the bone-implant interface

    By virtue of certain design features, bone anchored metal implants can be made to elicit a strong initial osteogenic response, i.e., the amount of bone formed. While quantitative differences are often lost at longer follow up times, do differences in the initial osteogenic response lead to …

    goteborg Repository record for Osteocytes as indicators of bone quality - multiscale structure-composition characterisation of the bone-implant interface (opens in a new tab)

  16. INVESTIGATION OF NOVEL BIOACTIVE ORTHOPAEDIC MATERIAL FUNCTIONALIZATIONS TO TARGET BONE-IMPLANT INTEGRATION IN OSTEOPOROTIC BONE

    Osteoporotic bone, which has porous architecture due to pathophysiological imbalance, poses a recurring challenge for bone-implant integration. In this work, localized delivery systems for osteogenic molecules such as estradiol (E2) and strontium ions (Sr) were investigated. Localised delivery of …

    nus Repository record for INVESTIGATION OF NOVEL BIOACTIVE ORTHOPAEDIC MATERIAL FUNCTIONALIZATIONS TO TARGET BONE-IMPLANT INTEGRATION IN OSTEOPOROTIC BONE (opens in a new tab)

  17. Bone-implant interface. Evaluation of osteoblastic cells behavior on nanopatterned titanium surfaces: an in vitro analysis

    Protein-adsorption occurs immediately following implantation of biomaterials. It is unknown at which extent protein-adsorption impacts the cellular events at bone-implant interface. To investigate this question, we compared the in-vitro outcome of osteoblastic cells grown onto titanium substrates …

    bologna Repository record for Bone-implant interface. Evaluation of osteoblastic cells behavior on nanopatterned titanium surfaces: an in vitro analysis (opens in a new tab)

  18. Linear and non-linear finite element modeling of bone-implant system in uncemented total hip arthroplasty

    … effects of different factors involved in the bone-implant system. A three-dimensional (3D) unsymmetric beam model, based on a potential energy formulation, for the analysis of stresses in long bones was developed in this research. The cross-sectional properties of the bone were obtained …

    rice Repository record for Linear and non-linear finite element modeling of bone-implant system in uncemented total hip arthroplasty (opens in a new tab)

Page 1 of 10