Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Bone screws"”.

  1. Bending fatigue of cancellous bone screws used in anterior spine surgery.

    … diameter (3.2mm inside diameter) cancellous bone screws. Fractography was used to qualify and quantify the failure mode. Fracture mechanics was used to determine the load level from the fractographic findings. These results were used in a test program to reproduce the fatigue failures seen …

    ottawa-retro Repository record for Bending fatigue of cancellous bone screws used in anterior spine surgery. (opens in a new tab)

  2. Novel biomechanical test method for cancellous bone screws and screw augmentation with cement.

    … plate constructs in fractures with poor quality bone or in metaphyseal bone with extensive bone loss or comminution[7][17]. Furthermore, rescuing or augmenting failed screw fixation in inadequate bone with various cement products has yielded mixed results when tested with pure axial pullout …

    louisville Repository record for Novel biomechanical test method for cancellous bone screws and screw augmentation with cement. (opens in a new tab)

  3. Cervical spine bone anchoring system CSBAS pullout testing and comparisons

    … the newly designed and patented Cervical Spine Bone Anchoring System (CSBAS). It is a posterior fixation device intended to be used with spine bone-plate systems. Its purposes are to substitute for conventional bone screws, significantly decrease the neurological and vascular risks associated …

    njit Repository record for Cervical spine bone anchoring system CSBAS pullout testing and comparisons (opens in a new tab)

  4. Effect of Synthetic Marrow on Synthetic Open-Cell Foam Vertebrae

    … the Analogue Spine Model (ASM) by introducing a bone marrow component. Currently the ASM does not include a bone marrow component. While not mechanically relevant, bone marrow does have an effect on bone cement intrusion. Techniques such as brushing (removing surface debris) and pressurized …

    ku Repository record for Effect of Synthetic Marrow on Synthetic Open-Cell Foam Vertebrae (opens in a new tab)

  5. Screw fixation of implants to the spine

    Bone screws are used to fix various implants to the human spine. Screw fixation can be difficult in osteoporotic bone because of its reduced strength. This research aimed to investigate screw fixation techniques in the spine. A questionnaire study, representing British and Irish spine surgeons, …

    birmingham Download PDF for Screw fixation of implants to the spine (opens in a new tab)

  6. Finite Element Representation of Bone-Screw Mechanics

    … or arm. Fixation using locking plates and bone screws has become the treatment of choice; however, an overall complication rate of 49% has been reported, with 7.5% resulted from failure of the bone-screw interface. Accordingly, the purpose of the work presented in this thesis is to develop …

    denver Repository record for Finite Element Representation of Bone-Screw Mechanics (opens in a new tab)

  7. Design of an In-situ Spinal Rod Cutter for Orthopaedic Surgeons

    … is often required. Implant rods are attached by bone screws to the spinal vertebrae to correct these deformities and stabilize the spine. It can be difficult to cut these rods to the ideal length before implantation and sometimes these rods are too long and must be cut in-situ. Also, when …

    waterloo Repository record for Design of an In-situ Spinal Rod Cutter for Orthopaedic Surgeons (opens in a new tab)

  8. Evaluation der BoneWelding® Technologie zur Verankerung von Implantaten im Knochen : eine Studie am Schaf

    Einführung: Die innovative BoneWelding® Technologie eröffnet völlig neue Möglichkeiten Implantate im Knochen zu verankern. Mittels Ultraschallenergie aufgeschmolzener abbaubarer Kunststoff (Poly-L-DL-Laktid) dringt in die Strukturen des vorgebohrten Knochens und kann somit auch in mechanisch …

    zurich

  9. Biomechanical analysis of slipped capital femoral epiphysis with single and double screw fixation

    Thesis (M.S.)--Michigan State University. Department of Metallurgy, Mechanics and Materials Science, College of Engineering, 1990

    msu Repository record for Biomechanical analysis of slipped capital femoral epiphysis with single and double screw fixation (opens in a new tab)

  10. Stability of the Miniscrew-Bone Interface: Reverse Torque Values in Rabbits

    Introduction: Miniscrews are used in orthodontics as practical temporary anchorage devices (TAD's). The purpose of this animal study was to measure reverse torque values for Absoanchor 1.2 mm and Micerium 1.5mm miniscrews at 0, 2, and 12 weeks under loaded and unloaded conditions. Methods: …

    loma-linda Repository record for Stability of the Miniscrew-Bone Interface: Reverse Torque Values in Rabbits (opens in a new tab)

  11. Dynamisierung der Cis-Kortex durch Einsatz von "Dynamic Locking Screws" in einer mit "Locking compression plates" fixierten Tibiaquerosteotomie: eine experimentelle Studie an Schafen

    … was to evaluate two types of dynamic locking screws in comparison to the standard bicortical locking head screw (LS). One of the dynamic screws was developed and produced by Synthes® Switzerland (dynamic locking screw, DLS), the other one was produced to match the far cortical locking screw …

    zurich

  12. Effect of Fixation Using Locked Compression Plate versus Lag Screws on Biomechanics of Talonavicular Joint: A Human Cadaveric Foot Model

    … a locked compression plate plus one screw or two screws. Six specimens (plate screw group) received the plate plus a lag screw, where the screw was inserted in a retrograde manner. Seven specimens (two screw group) received two lag screws, both inserted in retrograde manner. Three dimensional …

    tenn-hsc Repository record for Effect of Fixation Using Locked Compression Plate versus Lag Screws on Biomechanics of Talonavicular Joint: A Human Cadaveric Foot Model (opens in a new tab)

  13. Thermal exposure during bone drilling is a component of surgical trauma in osteosynthesis

    … centuries, to remove material from a workpiece. Bone drilling is performed routinely by surgeons of many disciplines including orthopaedics, spine, plastic, ear nose and throat, craniomaxillofacial, dentistry and veterinary, often to prepare a defect for insertion of an implant such as a bone …

    unsw Repository record for Thermal exposure during bone drilling is a component of surgical trauma in osteosynthesis (opens in a new tab)