Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 149 for “"Bragg Peak"”

  1. Feasibility and constraints of Bragg peak FLASH proton therapy beam delivery and treatment planning

    Spread-out Bragg peak FLASH proton therapy (FLASH-PT) aims to use ultra-high dose rates to elicit a normal tissue sparing effect whilst maintaining the anti-tumour effectiveness of conventional proton therapy. Conventional energy-modulation techniques used in intensity modulated proton therapy …

    oxford Repository record for Feasibility and constraints of Bragg peak FLASH proton therapy beam delivery and treatment planning (opens in a new tab)

  2. Investigations on multilateration of ionoacoustic signals for localisation of the bragg peak in pre-clinical research

    … correlate the measurable signal, beam range, or Bragg peak (BP) position. Additionally, their equipment is bulky and not cost-effective. Therefore, the research conducted during this work proposes a range verification method that is both cost-effective and establishes a direct correlation between …

    lmu-germany Repository record for Investigations on multilateration of ionoacoustic signals for localisation of the bragg peak in pre-clinical research (opens in a new tab)

  3. Development of a multi-purpose proton microbeam system: irradiation of tumor cells by energetic protons at the Bragg peak

    Employing ionization radiation to serve our communities has various applications in agricultural, industrial, and medical fields. The application of physics to medicine deals mainly with ionizing radiation in diagnosis and treating human therapeutic. Radiation treatment is a commonly utilized …

    ecu Repository record for Development of a multi-purpose proton microbeam system: irradiation of tumor cells by energetic protons at the Bragg peak (opens in a new tab)

  4. SPOT SCANNING PROTON BEAMS CHARACTERIZATION VIA PLASTIC SCINTILLATOR DETECTOR

    … Measurements were benchmarked against a PTW Bragg Peak Chamber and a TOPAS Monte Carlo model built on validated phase space files for the ProBeam nozzle. In depth-dose measurements, the raw detector signal tracked the Monte Carlo dose accurately through the entrance plateau but lost up to 44% …

    fau Repository record for SPOT SCANNING PROTON BEAMS CHARACTERIZATION VIA PLASTIC SCINTILLATOR DETECTOR (opens in a new tab)

  5. Jonų implantacijos poveikio izoliacinių sričių susidarymui AlGaN/GaN puslaidininkinėse struktūrose tyrimas /

    … is almost the same (~1,8*10^9 vac. / (cm*ion)), Bragg peak is at 120 nm and 90 nm depth. Using SIEMENS (C51H34O9S2) photoresist there is less created amount of vacancies (7,74*10^8 vac. / (cm*ion)), and Bragg peak is near 100 nm. After performed aluminum ion implantation into AlGaN/GaN …

    vilnius Repository record for Jonų implantacijos poveikio izoliacinių sričių susidarymui AlGaN/GaN puslaidininkinėse struktūrose tyrimas / (opens in a new tab)

  6. Actions of high energy protons on mammalian cells: The influences of linear energy transfer and of dose rate

    … the proton beam, but poorly at, and beyond, the Bragg peak, where the linear Energy Transfer (LET) rises rapidly. It seemed likely that this increase in LET at the Bragg peak would cause a concomitant increase in RBE. Experiments were therefore designed to determine Bragg peak-RBE. Bateman, Bond …

    bu Repository record for Actions of high energy protons on mammalian cells: The influences of linear energy transfer and of dose rate (opens in a new tab) Embargoed until 2999-01-01

  7. Fiducial-free alignment verification techniques for intracranial radiosurgery

    … due to the dosimetry advantage of the Bragg peak. The Bragg peak is a phenomenon exploited by proton beam therapy to concentrate the effect of the beams on the tumor while minimizing damage to critical structures and other health tissues within the patient.

    csusb-retro Repository record for Fiducial-free alignment verification techniques for intracranial radiosurgery (opens in a new tab)

  8. Fiducial-free alignment verification techniques for intracranial radiosurgery

    … due to the dosimetry advantage of the Bragg peak. The Bragg peak is a phenomenon exploited by proton beam therapy to concentrate the effect of the beams on the tumor while minimizing damage to critical structures and other health tissues within the patient.

    csusb Repository record for Fiducial-free alignment verification techniques for intracranial radiosurgery (opens in a new tab)

  9. The resolution function of triple-crystal X-ray diffractometer and its applications

    … form describing the intensity distribution of a Bragg peak in reciprocal space is derived. The dynamical streaks associated with a Bragg peak and the width of the resolution function under the Gaussian approximation are studied in detail. The theory of absolute integrated intensity measurement by …

    mcgill Repository record for The resolution function of triple-crystal X-ray diffractometer and its applications (opens in a new tab)

  10. Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams

    … dose gradients as a result of positioning the Bragg peak to cover the volumes to be treated. The Bragg peak can be shifted significantly in the patient as a result of nonuniformities in the tissue composition in its path, which can result in treatment complications. Some traditional dose …

    uthsc Repository record for Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams (opens in a new tab)

  11. Geant4 based Monte Carlo simulation for carbon fragmentation in nuclear emulsion

    … its energy in the narrow region which is called Bragg Peak. On the other hand, the main side effect of heavy-ion therapy is the radiation dose beyond the Bragg Peak which damages the healthy tissues. Therefore the use of heavy-ion in cancer therapy requires accurate understanding of ion-matter …

    metu Repository record for Geant4 based Monte Carlo simulation for carbon fragmentation in nuclear emulsion (opens in a new tab)

  12. Determination of Dose From Light Charged Ions Relevant to Hadron Therapy Using the Particle and Heavy Ion Transport System (PHITS)

    … area of high dose localization is known as the Bragg Peak. Exploitation of the Bragg Peak could lead to more efficient non-invasive treatment plans by reducing the dose in healthy tissues. Using the Particle and Heavy Ion Transport System (PHITS), the dose and fragmentation particles from ions …

    tamu Repository record for Determination of Dose From Light Charged Ions Relevant to Hadron Therapy Using the Particle and Heavy Ion Transport System (PHITS) (opens in a new tab)

  13. Carbon-ion radiation biological lethal dose distribution

    … and deposition around the carbon-ion beam Bragg peak. Furthermore, its high-LET components allow for the treatment of tumors displaying radioresistance to low-LET radiotherapy modalities. Purpose: This present study was designed to investigate the biological range in which the carbon-ion …

    colostate Repository record for Carbon-ion radiation biological lethal dose distribution (opens in a new tab)

  14. X-ray intensity fluctuation spectroscopy of the ordering in Cu3Au

    … is used to record the (100) superlattice Bragg peak and the speckle pattern. We analyze the Bragg peak and summarize its properties. The universal scaling law is tested and is observed to be in good agreement with the theory. The average domain size (inverse of Bragg peak width) obeys the …

    mcgill Repository record for X-ray intensity fluctuation spectroscopy of the ordering in Cu3Au (opens in a new tab)

  15. Laser-driven charged particle transport in warm dense matter and plasma

    … and (ii) ion stopping power close to the Bragg peak in extreme states of matter. Both topics have been investigated in an integrated approach that combines experimental campaigns with detailed theoretical and numerical studies used to support the experiments both in the design prior to the …

    salamanca Repository record for Laser-driven charged particle transport in warm dense matter and plasma (opens in a new tab)

  16. Computer Simulation and Comparison of Proton and Carbon Ion Treatment of Tumor Cells Using Particle and Heavy Ion Transport Code System

    … method of cancer treatment. Because of their Bragg peak dose distribution, protons are an effective way to deliver a dose to the tumor, while minimizing the dose to surrounding tissue. Charged particles with greater mass and higher charge than protons have an even sharper Bragg peak and a …

    tamu Repository record for Computer Simulation and Comparison of Proton and Carbon Ion Treatment of Tumor Cells Using Particle and Heavy Ion Transport Code System (opens in a new tab)

  17. Optimization of Proton Therapy by Estimation of Therapeutic Proton Spectrum and Verification of Proton Range.

    … the nuclear physics occurring around the Bragg peak, to better understand and control dose deposition within the Bragg peak. In the first study, we developed a novel method to measure the peak energy of therapeutic proton beams. Activation of an element with multiple proton interaction …

    okstate Repository record for Optimization of Proton Therapy by Estimation of Therapeutic Proton Spectrum and Verification of Proton Range. (opens in a new tab)

  18. Experimental evaluation of polychromatic neutron diffraction

    … powder. The intensity and resolution of the Bragg peaks with the instrument in this configuration were compared to Bragg peaks measured by the same instrument in a monochromatic configuration. The intensity of the polychromatic mode was only comparable to the monochromatic mode with looser …

    mit Repository record for Experimental evaluation of polychromatic neutron diffraction (opens in a new tab)

  19. Mechanically Robust Ordered Nanocomposites Exhibiting a NIR Bandgap

    … nanocomposites were optically active and the Bragg diffracted light in a NIR region and wavelength of the Bragg peak could be tuned simply by changing the silica concentration in the composite. They also exhibited intense angle dependent iridescence.

    temple Repository record for Mechanically Robust Ordered Nanocomposites Exhibiting a NIR Bandgap (opens in a new tab)

  20. Acute Effects of Whole-Body Proton Irradiation on the Immune System of the C57BL/6 Mouse

    … Gy/min dose rate) of either proton WBI at the Bragg peak, proton WBI at the entry plateau, or Co WBI, and sacrifice intervals were at 1,4, 7, and 10 days post- WBI. Flow cytometry analysis of the spleen and peripheral blood showed depression in cell counts for all time points when compared to …

    loma-linda Repository record for Acute Effects of Whole-Body Proton Irradiation on the Immune System of the C57BL/6 Mouse (opens in a new tab)

Page 1 of 8