Novel Methods for Reducing Breast Dose During Computed Tomography Scans
… at higher risk for developing radiation-induced breast cancer later in life. Thus, the purpose of this thesis was to both accurately quantify dose and explore new strategies for CT breast dose reduction. In order to determine dose reduction, dose quantification was first assessed through the …
-
Dynamic Wedge Versus Conventional Wedge: A Comparison of Contralateral Breast Dose
Made available in DSpace on 2017-07-06T18:55:38Z (GMT). No. of bitstreams: 3 Nguyen_Thinh_T_MS.pdf: 31187564 bytes, checksum: 0ff3c0afc98cbac7cba79b62a5d95656 (MD5) Nguyen_Thinh_T_MS_ABS.pdf: 1005480 bytes, checksum: 6141e12b1ec0e0cf8c0396a833cc2062 (MD5) license.txt: 4813 bytes, checksum: …
-
Characterization of a Solid-State Detector for Dosimetry in the Diagnostic Energy Range with Verification via Monte Carlo Estimation of Average Breast Dose in Mammography
… a simplified QA metric for estimating radiation dose in mammography. This metric, the Mid-Breast Dose (MDB) Index, maybe be proposed as an alternative dose index, consistent with average glandular dose (AGD), for routine QA. MBD was obtained using “Phantom mid-point Air Kerma (AK) measurement” …
-
Reducing Radiation Dose to the Female Breast During Conventional and Dedicated Breast Computed Tomography
… effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing …
-
Reducing the Radiation Dose to Women Receiving Cardiac CT Scans
… aims to quantify the reduction in radiation dose deposited in glandular breast tissue achieved by using tilted gantry acquisition during cardiac CT scans. Previous work by Halpern et al. suggested using tilted acquisition parallel to the long axis of the patient’s heart. However, for a larger …
-
The Effects of Organ-based Tube Current Modulation on Radiation Dose and Image Quality in Computed Tomography Imaging
The purpose of this thesis was to quantify dose and noise performance of organ-dose-based tube current modulation (ODM) through experimental studies with an anthropomorphic phantom and simulations with a voxelized phantom library. Tube current modulation is a dose reduction technique that modulates …
-
Image quality, dose, and quality control in screen-film and full-field digital mammography
… to FSM under the constraint of matched patient dose, and 3) technical comparison of the first clinical FFDM units in the United States to FSM. Medical physics testing was performed at participating sites in the Colorado Mammography Advocacy Project (CMAP) to assess breast dose, image quality, …
-
Δοσιμετρία με Monte Carlo προσομοίωση σε εξετάσεις μαστογραφίας με ψηφιακές και τομογραφικές τεχνικές
Breast cancer has a significant impact on the well-being of the female population both nationwide and worldwide. Although the incidence of breast cancer has increased over the past two decades, mortality has steadily decreased. An important factor contributing to successful treatment is early …