Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"Bridge circuits"”
-
A converter model for the digital simulation of transients in AC/DC transmission systems
… of a converter model which enables the converter bridge circuits to be represented in detail and the valve ignition to be controlled in the constant current mode. The model has been added to the U.B.C. Electromagnetic Transients Program to permit simulations of the complete ac/dc system. It is …
-
Operation and Calibration Procedures for a Small Four-component Strain Gage Balance
… mounted on the balance and wired into four full bridge circuits. When the balance is subjected to a load, the strain gages, through a small resistance change, indicated the strain a balance element is undergoing. This report presents a description of the balance and its support equipment, and …
-
Detection and analysis through communication channels of the physical characteristics of metals by using of ultrasonic sensors
… strain gages functional converters in classical bridge circuits for monitoring and control of power loads has been introduced. One of the most important aspects in modern communications is related to the identification and assessment of superimposed unwanted random noises in the communication …
-
A HIGHLY PRECISE AND LINEAR IC FOR HEAT PULSE BASED THERMAL BIDIRECTIONAL MASS FLOW SENSOR
… response received from analog integrated circuits. A computational fluid dynamic (CFD) model was designed for simulations with air and water Using COMSOL Multiphysics. Established mathematical models for the heat flow equations including CFD parameters were used within COMSOL …
-
A Soft-Switched Grid-Connected DC/AC Inverter with Low Current Ripple
… DC/AC inverters are based on simple full-bridge circuits with hard switching. However, hard-switching imposes several difficulties on the performance of DC/AC inverters. Thus, increasing the efficiency and decreasing the switching losses of these inverters have been an active research …
-
Development of an Electrotactile Haptic Device with Application to Balance Rehabilitation
… stimulation devices require working knowledge of circuits, thus there is mainly a general lack of instructions for the design of such devices. The thesis hopes to address these gaps by studying a design that may be simple to replicate from scratch. The design includes the use of several half …
-
A Multi-level Multi-Modular Flying Capacitor Voltage Source Converter for High Power Applications
… responses to this need. These use half or full H-bridge circuits stacked up to form a chain, and hence can withstand high voltages using lower-rated switching devices. This thesis introduces a new member into the MMC family, i.e the Modular Multi-level Flying Capacitor Converter (MMFCC). This uses …
-
A STUDY OF SEMICONDUCTOR STRAIN GAUGES
… gauge non-linearity and gauge energization circuits. Studies of bridge circuits were also carried out and a special bridge/amplifier system, which was devised for use with semiconductor strain gauges, is described and assessed. Investigations of the thermal characteristics are then reported …
-
Analysis of Modulation and Voltage Balancing Strategies for Modular Multilevel Converters
… converter is made up of a series of IGBT half-bridge circuits with a capacitor across both devices. Benefits of this converter include reduced semiconductor device costs due to the ability to use more commercially available low-rated IGBTs and reduced or potentially the elimination of filter …
-
Advancing Multi-Axis Force/Torque Sensing via Beam Optimization, Self-Decoupling Mechanisms, and Morphing-Based Mechanical Intelligence
… piezoresistive films and a modified Wheatstone-bridge interface. This compact, volume-efficient design eliminates the need for a rigid frame, confines deformation to the free-end beams, and maximizes strain utilization. Symmetric placement of the sensing films combined with the modified bridge …
-
The determination of the electrical conductivities of aqueous solutions of the methylamine hydrochlorides by means of a specially designed bridge, amplifier, and other equipment
A completely shielded bridge and amplifier have been described. A constant temperature bath and a thermoregulator accurate to ±0.001°C. have been described. The molar conductances of the methylamine hydrochlorides in aqueous solution and the densities of the solutions have been determined at 25°C. …
-
Microengineered thermal conductivity vacuum pressure sensor
… technology. A monolithic polysilicon air-bridge structure (supported at both ends), within a Wheatstone bridge circuit, is used as a pressure sensor. The device utilizes the change of the thermal conductivity of a gas with ambient gas pressure. The doubly supported beam functions as a …
-
A study of the specific membrane properties in different types of smooth muscle
… the same microelectrode using the Wheatstone bridge method.</p> <ol type="a"><li><p><em>Effect of intracellular current application on single cells.</em></p> <p>The experiments were carried out on the spontaneously active taenia coli of the guinea-pig. The spontaneous discharge consisted of a …