  1. Investigation of bubble dynamics and heating during focused ultrasound insonation in tissue-mimicking materials

    … in tissue can cause tissue damage due to local heating. For pressures above a critical threshold, cavitation will occur in tissue and bubbles will be created. These oscillating bubbles can induce a much larger thermal energy deposition in the local region. Traditionally, clinicians and …

    bu Repository record for Investigation of bubble dynamics and heating during focused ultrasound insonation in tissue-mimicking materials (opens in a new tab)

  2. The application of phase-shift nanoemulsion in high intensity focused ultrasound: an in vitro study

    … been well documented that the presence of microbubbles at the HIFU focus during sonication can increase the absorption of ultrasound energy and thus accelerate heating in tissue. As a result, the time and acoustic energy required for an effective treatment can be significantly reduced. However, …

    bu Repository record for The application of phase-shift nanoemulsion in high intensity focused ultrasound: an in vitro study (opens in a new tab) Embargoed until 2999-01-01

  3. Investigation of Microbubble-enhanced Mild Hyperthermia with Focused Ultrasound for Drug Delivery Enhancement

    … results in increased drug uptake of the tumor. Heating of the tumor can be performed via High Intensity Focused Ultrasound (HIFU) however, HIFU focuses energy onto a millimeter size area. Prior work has shown that adding microbubbles during HIFU can enhance the heating. It was suggested that …

    washington Repository record for Investigation of Microbubble-enhanced Mild Hyperthermia with Focused Ultrasound for Drug Delivery Enhancement (opens in a new tab)

  4. High-intensity focused ultrasound (HIFU) induced hyperechoic regions for the ultrasound guidance of HIFU therapy

    … measurements showed the initial formation of bubbles at the HIFU focus to be due to acoustic cavitation alone or in conjunction with boiling. In addition, the formation of a hyperechoic region resulted in bubble-enhanced heating at the treatment site.The short- and long-term (0 h--14 days) …

    washington Repository record for High-intensity focused ultrasound (HIFU) induced hyperechoic regions for the ultrasound guidance of HIFU therapy (opens in a new tab)