Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 69 for “"Bubble chamber"”
-
Magnetic Bubble Chamber Prototype Development
It is now evident that the majority of matter in our universe is composed of non-luminous dark matter. However, the nature of this dark matter remains mysterious. The most promising candidates for dark matter include axions and weakly interacting massive particles (WIMPs). Current leading direct …
-
Bubble chamber studies of nuclear structure
… been investigated using a twelve-inch propane bubble chamber and the full energy proton beam from the Harwell synchrocyclotron.</p> <p>A series of experiments on the external proton beam led to the establishment of a beam with an energy spread of less than 0.5 MeV; this enabled the bubble …
-
Dark Matter Search with the PICO-40L Bubble Chamber
… The PICO collaboration, which operates bubble chambers in the search for WIMP-like dark matter, is currently operating the PICO-40L experiment at SNOLAB in Sudbury, Ontario, Canada. PICO-40L, the first large-scale implementation of the so-called "right side up" design, has been …
-
Polarization of positive muons in a freon bubble chamber
Thesis (M.S.)--Michigan State University of Agriculture and Applied Science. Dept. of Physics, 1960
-
Dark Matter Limits from a 2L C3F8 Filled Bubble Chamber
The PICO-2L C3F8 bubble chamber search for Weakly Interacting Massive Particle (WIMP) dark matter was operated in the SNOLAB underground laboratory at the same location as the previous CF3I filled COUPP-4kg detector. Neutron calibrations using photoneutron sources in C3F8 and CF3I filled …
-
Dark Matter Limits from a 2L C3F8 Filled Bubble Chamber
The PICO-2L C3F8 bubble chamber search for Weakly Interacting Massive Particle (WIMP) dark matter was operated in the SNOLAB underground laboratory at the same location as the previous CF3I filled COUPP-4kg detector. Neutron calibrations using photoneutron sources in C3F8 and CF3I filled …
-
A Model of bubble nucleation efficiency for bubble chamber detector
Bubble chambers using fluorocarbons or noble liquids gases are promising tools for detecting low-energy nuclear recoils caused by the elastic scattering of weakly interacting massive particles (WIMPs), a type of dark matter. These chambers comprise a vessel filled with a superheated liquid, which …
-
Bubble chamber film: the development of an online control system
… been developed for the measuring of events on bubble chamber film. The system is controlled by an IBM 1130 computer with 8K words of core, and a core cycle time of 3.6ysec. Up to six measuring machines may be operated simultaneously, and the system will also handle the collection of data from a …
-
A bubble chamber study of pion photo-production from hydrogen
… pion-nucleon scattering and photoproduction. A bubble chamber specially adapted for use with a high energy photon beam has been developed. The containment of any desired target material in a tube passing through the chamber and the ability to operate with either propane or freon ( CF3 BR ) gives …
-
Neutrino-nucleon interactions in the Tohoku 1.4-meter bubble chamber
… of neutrinos with freon in the Tohoku 1.4-Meter Bubble Chamber, with emphasis on those interactions that produce slow protons emerging in the final state. The bubble chamber was exposed in 1985 and 1987 to the Fermilab wide-band neutrino beam generated by 800 GeV protons at the Tevatron. …
-
Study of the Response of a New Continuous Compressionless Bubble Chamber
Bubble chambers filled with fluorocarbons are a world-leading technology to search for nuclear recoils produced by spin-dependent WIMP dark matter particles. In this work, a novel bubble chamber using 28 ± 1 ml of the fluorocarbon C5F12 as target material is investigated. This superheated liquid …
-
Anomalous Background and Calibration of PICO Bubble Chamber Dark Matter Detectors
… with Fluorine in superheated freon-filled bubble chambers. Despite mitigation efforts, PICO detectors are subject to nuisance particle backgrounds which must be well understood in order to extract a potentially underlying WIMP signal. PICO-40L is currently constructed 2km underground at …
-
The characteristics of a bubble chamber using liquid nitrogen and argon
… and fundamental particles. This device, the bubble chamber, makes use of a superheated liquid to display the path of a charged particle as a trail of small bubbles. The bubble chamber has several features which make it more useful in many experiments than either the cloud chamber or the …
-
A Liquid Hydrogen Bubble Chamber Designed for Use as a Neutron Spectrometer
A liquid hydrogen bubble chamber for use as a neutron spectrometer has been constructed and operated. The chamber employs 90o stereography and is expanded by a piston located in the liquid. The construction and operation of the chamber are described. A special measuring microscope for analyzing the …
-
PICO-60: A Dark Matter Search Experiment with C3F8 in a Bubble Chamber
The PICO-60 experiment was a bubble chamber for the search of Weakly Interacting Massive Particle (WIMP) dark matter. The previous run of PICO-60, conducted in 2013, was limited in sensitivity by background events that were most likely caused by particulate contamination and the buffer liquid. …
-
A cloud and bubble chamber study of proton-proton interactions at 970 MeV
… at 970 MeV. A high pressure diffusion cloud chamber was filled with hydrogen at 25 atmospheres and operated in the proton beam from the Birmingham synchrotron. A pulsed magnetic field of 13,000 oersted, applied to the chamber, enabled momenta of primary and secondary particles to be measured. …
-
Alpha Spectroscopy in a Superheated Bubble Chamber and the Design of the PICO-500 Hydraulic Control Cart
… study used background data from the PICO-40L bubble chamber to perform spectroscopic alpha decay analysis. The analysis results showed an improvement in the resolution of the AP and set upper limits on alpha decay rates from the Uranium and Thorium decay series in PICO-40L. Furthermore, the …
-
Calibration of the PICO-0.1 bubble chamber and development of coated inner vessels for dark matter search
… Interacting Massive Particles (WIMPs) with bubble chambers. In this thesis, results from calibrations of the PICO-0.1 test chamber is presented. Calibrations were performed at the Tandem Van de Graaff facility of the Université de Montréal. Monoenergetic neutrons were produced from the …
-
A Study of the Muon Veto and Cosmogenic Neutron Background for the Scintillating Bubble Chamber Dark Matter Experiment
… to search for these particles. The Scintillating Bubble Chamber (SBC) is one such experiment. The SBC is a bubble chamber using a scintillating target fluid allowing it to reach lower energy thresholds than previous bubble chamber experiments. This thesis investigates one major background for the …
-
A survey of bubble chamber results on differential cross-sections for high energy π(^+)p quasi two body interactions
… in π(^+)p interactions studied in hydrogen bubble chambers. The first two chapters outline the theoretical background for the description of such interactions. The third chapter discusses kinematical and observational effects which can influence the measured shape of the. differential cross- …
Page 1 of 4