Hydrocarbon bubble chambers
Abstract Not Provided.
-
Experiments with hydrocarbon bubble chambers
Abstract Not Provided.
-
Bubble growth dynamics for C3F8 bubble chambers
… dark matter search experiment that utilizes bubble chambers and the acoustics of growing bubbles to discriminate signal from background events [5]. It has been shown that temperature perturbations from equilibrium significantly affect the growth of a bubble in superheated water [17], …
-
Bubble formation and growth In superheated liquid bubble chambers
Bubble chambers are a type of particle detector that make use of the superheated state to detect minute energy depositions. Early studies of nucleation in bubble chambers provide evidence that, if sufficient energy is deposited within a region of the superheated liquid, it triggers nucleation of a …
-
The PICO-2L program: Towards Background-Free Dark Matter Direct Detection Using Bubble Chambers
… in 2013 with the deployment of a 2 litre bubble chamber filled with superheated C3F8 and over the next three years, conducted two separate WIMP-search experiments. The first run was conducted at 4 different energy thresholds ranging from 3.2 keV to 8.1 keV and a total of 12 candidate …
-
New ideas for tonne-scale bubble chambers and a search for superheavy dark matter with PICO-60
The PICO dark matter search experiments using bubble chambers have been successful in probing the potential WIMP-proton scattering cross section. The largest of these experiments (PICO-60 and PICO-40) contain approximately 50~kg of the superheated liquid Freon C$_3$F$_8$ in a quartz vessel. Future …
-
Calibration of the PICO-0.1 bubble chamber and development of coated inner vessels for dark matter search
… Interacting Massive Particles (WIMPs) with bubble chambers. In this thesis, results from calibrations of the PICO-0.1 test chamber is presented. Calibrations were performed at the Tandem Van de Graaff facility of the Université de Montréal. Monoenergetic neutrons were produced from the …
-
New Approaches for Acoustic Analysis in PICO Dark Matter Searches
… experiment, using superheated fluorocarbons in bubble chambers, has set world-leading limits on the WIMP-proton cross section with multiple detectors. One strength of the PICO experiment is its exceptional background rejection methods, particularly in background events from alpha particles, …
-
The Search for Low Mass Dark Matter with the NEWS-G and SBC Experiments
… proportional counters (SPCs) and scintillating bubble chambers (SBCs) respectively. This thesis presents the progress made in the characterization and understanding of the physics relevant to both technologies. This includes measurements of the ionization yield of SPCs, the development of novel …
-
Light collection as a veto for PICO and SBC dark matter searches
Bubble chambers are a promising technology for dark matter detection that use a superheated fluid as the detection medium, where only point-like energy depositions can initiate a bubble nucleation event. PICO and the Scintillating Bubble Chamber (SBC) collaborations use bubble chambers with the …
-
Performance Analysis and Quality Control for the PICO Dark Matter Program
… using an active liquid of superheated Freon in bubble chambers, which provide excellent background discrimination for nuclear recoils. PICO-500 is the next generation tonne-scale detector being assembled at SNOLAB. The PICO-500 Inner Vessel cleaning campaign was conducted in a Class 100 …
-
Radiation Effects on Metastable States of Superheated Water
… of Positron Emission Tomography target design, bubble chambers, and superheat measurements are presented. The quantitative theory of metastable liquids and their characteristic waiting time is discussed. Energetics of bubble formation from two different perspectives are included. Finally, the …
-
Breaking the Tension: Development and Investigation of a Centrifugal Tensioned Metastable Fluid Detector System
… a theoretical treatment and experience with bubble chambers may be applied with some degree of success, they are no substitute for experimental and operational knowledge of real CTMFD systems. This research, as with other investigations into CTMFD systems in the past, applies theory and …
-
A survey of bubble chamber results on differential cross-sections for high energy π(^+)p quasi two body interactions
… in π(^+)p interactions studied in hydrogen bubble chambers. The first two chapters outline the theoretical background for the description of such interactions. The third chapter discusses kinematical and observational effects which can influence the measured shape of the. differential cross- …
-
The PICO Dark Matter Search: Reflections and Projections
… PICO experiment is one such effort, operating bubble chambers with fluorocarbon targets and offering unique sensitivity to spin dependent dark matter scattering. This thesis describes the motivation behind PICO and then presents a new retroreflector design for PICO-40L, the most recent PICO …
-
Dark Matter Limits from a 2L C3F8 Filled Bubble Chamber
The PICO-2L C3F8 bubble chamber search for Weakly Interacting Massive Particle (WIMP) dark matter was operated in the SNOLAB underground laboratory at the same location as the previous CF3I filled COUPP-4kg detector. Neutron calibrations using photoneutron sources in C3F8 and CF3I filled …
-
Study of the Response of a New Continuous Compressionless Bubble Chamber
Bubble chambers filled with fluorocarbons are a world-leading technology to search for nuclear recoils produced by spin-dependent WIMP dark matter particles. In this work, a novel bubble chamber using 28 ± 1 ml of the fluorocarbon C5F12 as target material is investigated. This superheated liquid …
-
A Model of bubble nucleation efficiency for bubble chamber detector
Bubble chambers using fluorocarbons or noble liquids gases are promising tools for detecting low-energy nuclear recoils caused by the elastic scattering of weakly interacting massive particles (WIMPs), a type of dark matter. These chambers comprise a vessel filled with a superheated liquid, which …