Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 44 for “"Building Automation System"”.
-
BUILDING AUTOMATION SYSTEM
… water resetting using an Energy Management System (EMS). The control strategy consists of 2 chilled water reset routines; "knowledge-base" routine and "search" routine. The main feature of the control strategy is to ensure that temperature possible. The required chilled is determined in the …
-
Building automation system cyber networks: an unmitigated risk to federal facilities
The General Services Administration accesses building-automation system technology that runsfederal facility processes such as HVAC, lighting, elevators, and access control via active Internet connections. Currently, these networks are not secure, despite legislation requiring them to be. This …
-
Information Technology & Sustainability: An Empirical Study of the Value of the Building Automation System
… way as the conservation of electric energy in buildings; economic value -- from energy cost savings; and BAS complements. These four constructs formed three propositions: (1) BAS implementation is positively associated with environmental value; (2) environmental value is positively associated …
-
A Bottom-Up Method to Calibrate Building Energy Models Using Building Automation System (BAS) Trend Data
Ongoing commissioning based on calibrated building energy models is one of the most promising means to improve the energy performance of existing buildings. Many calibration methods in the literature relied on whole-building utility data to calibrate building energy models. Recent studies revealed …
-
Building Automation Systems Design. Guidelines for Systems with Complex Requirements
Buildings today are becoming more and more advanced and the demands on building services are increasing. A modern building is expected to provide a number of services with high security, energy efficiency and convenience. For a building with complex requirements due to the activity, such as a …
-
A Secure Computing Platform for Building Automation Using Microkernel-based Operating Systems
Building Automation System (BAS) is a complex distributed control system that is widely deployed in commercial, residential, industrial buildings for monitoring and controlling mechanical/electrical equipment. Through increasing industrial and technological advances, the control components of BAS …
-
Model-Based Predictive Control of Window Shades
… total electricity savings of 35% in a complete building automation system. Later, these methodologies were adapted and utilized in a demonstrative setting built within a research facility to attempt and identify the challenges associated with the scaling of the approach. The results showed an …
-
detection and diagnosis of multiple dependent faults in HVAC systems using machine learning techniques
The building sector accounts for about 40% of the total annual energy consumption in the United States and 25% in Canada. Therefore, it is so essential to design and operate energy-efficient smart buildings. About 15 to 30% of the energy in the commercial buildings would be wasted if the heating, …
-
An Automated Building Energy Model Calibration Workflow to Improve Indoor Climate Controls
Calibrating a white-box building energy model (BEM) is time-consuming and prohibitively expensive due to the large number of required model inputs and the limited availability of measurements. Therefore, this research aims to increase the calibration efficiency by proposing an improved workflow to …
-
Performance of chillers under variable operating conditions and the effectiveness of energy recovery via enthalpy wheels for building applications.
… wheels in air handling units in the HVAC system in the Baylor Research and Innovation Collaborative (BRIC) were evaluated. The data used in the evaluation were collected by the Siemens Building Automation System (BAS). Data were measured on the two identical 500-ton York chillers in the …
-
An Information Exchange Framework For BIM, BAS, And IoT Data Using Semantic Web Technologies
With digital technologies like Building Information Modeling (BIM), Internet of Things (IoT), and Building Automation System (BAS), an increasing amount of data is being created. Data silos in Architecture Engineering and Construction (AEC) industry emerged. The isolation between BIM-based building …
-
Ongoing commissioning of heat recovery process in a central heating and cooling plant
… to compare the incoming data collected by the building automation system against expected values. One approach is to develop inverse models from measured normal performance. The current thesis is based on data collected in a central heating and cooling plant operated in Montreal. As a measure …
-
NETWORK TRAFFIC CHARACTERIZATION AND INTRUSION DETECTION IN BUILDING AUTOMATION SYSTEMS
… operational trends and behaviors of a realworld building automation system (BAS) network for creating building device models to detect anomalous behaviors and attacks, (2) to design a framework for evaluating BA device security from both the device and network perspectives, and (3) to leverage …
-
THERMODYNAMIC MODELING OF CENTRIFUGAL CHILLERS
… The chiller plant is totally controlled by a Building Automation System (BAS), and comprises four units of centrifugal chillers (two chillers of 900 RT each and the other two of 450 RT each). They are configured to operate in parallel and can be scheduled to operate efficiently by the BAS, …
-
Development of Terminal Box Maintenance, FDD & Issue Management
… captured by rules. The thermal loads of the building spaces being unsatisfied by the terminal boxes cause faults that are captured by FDD. High thermal load building spaces can cause faults. The thermal loads can be exterior environmental loads such as solar radiation, conduction, convection, …
-
Development of Terminal Box Maintenance, FDD & Issue Management
… captured by rules. The thermal loads of the building spaces being unsatisfied by the terminal boxes cause faults that are captured by FDD. High thermal load building spaces can cause faults. The thermal loads can be exterior environmental loads such as solar radiation, conduction, convection, …
-
Energy modeling and calibration of a mixed-use building with laboratories, offices, and classrooms
In general, mixed-use building with laboratories, office, and classrooms consume a significant amount of energy and very energy intensive. These buildings provide great opportunities for energy efficiency improvement from mechanical and energy system, including Heating, Ventilation and …
-
Data Driven Energy Efficiency Strategies for Commercial Buildings Using Occupancy Information
Most building automation systems operate with settings based on design assumptions with fixed operational schedules and fixed occupancy, when in fact both schedules and occupancy levels vary dynamically. In particular, the heating ventilation and air conditioning (HVAC) system provides a minimum …
-
Calibration of a Building Energy Model Using Measured Data for a Research Center
… bottom-up methodology to calibrate a building energy model starting at the zone level, and finishing with the whole building level. The calibration is based as much as possible on measurements taken from the existing Building Automation System (BAS). This study presents the calibration …
Page 1 of 3