Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"C-column"”.

  1. Separation and quantitation of B-6 vitamers in rat plasma by high performance liquid chromatography

    … were accomplished using a reverse phase C₁₈ column; a binary system of methanol and heptane sulfonic acid, the ion pair; and a fluorescence detector using 300 nm excitation and 375 nm emission filters. The minimum detectable quantity was determined to be 5 ng for PL and PN and 4 ng for PM. …

    vt Repository record for Separation and quantitation of B-6 vitamers in rat plasma by high performance liquid chromatography (opens in a new tab)

  2. Liquid chromatographic separation and quantitation of B-6 vitamers in rat liver, kidney, and brain tissues

    … of a binary mobile phase, a µBondapak C₁₈ column, and a fluorescence detector was used to separate the B-6 vitamers pyridoxal (PL), pyridoxine CPN), and pyridoxamine (PM) as well as the internal standard deoxypyridoxine. An extraction procedure, compatible with the HPLC system, was …

    vt Repository record for Liquid chromatographic separation and quantitation of B-6 vitamers in rat liver, kidney, and brain tissues (opens in a new tab)

  3. Purification and partial characterization of a peptide cross reacting with antibodies to gastric inhibitory polypeptide

    … not adsorbed to alginic acid was applied to the column and the fraction which bound to the ligand was eluted with 100 mM HC1. The immunoreactive material was rotary evaporated to dryness and further purified to a monocomponent by HPLC. A µBondapak C₁₈ column and a linear gradient of acetonitrile …

    ubc Repository record for Purification and partial characterization of a peptide cross reacting with antibodies to gastric inhibitory polypeptide (opens in a new tab) Download PDF for Purification and partial characterization of a peptide cross reacting with antibodies to gastric inhibitory polypeptide (opens in a new tab)

  4. High resolution gas chromatography of conjugated estrogens with glass capillary columns

    … and β-estradiol/α-dihydroequilin, capillary column gas chromatography was investigated. A variety of derivatives of estrogens, suitable for gas chromatography, such as trimethylsilyl ethers, methoxime-trimethyl-silyl ethers, tert.butyl dimethyl silyl ethers, heptafluorobutyrates, …

    ubc Repository record for High resolution gas chromatography of conjugated estrogens with glass capillary columns (opens in a new tab) Download PDF for High resolution gas chromatography of conjugated estrogens with glass capillary columns (opens in a new tab)

  5. The transport of mineral and organic matter into the soil profile by Lumbricus rubellus Hoffmeister

    … with a newly developed method, using soil columns to which ¹⁴C labelled plant material was added. The feeding habits of the worm were positively influenced by temperature in wet soils (> -15m of water) and were negatively influenced in dry soil (< -15 m of water). The total egestion rate …

    ubc Repository record for The transport of mineral and organic matter into the soil profile by Lumbricus rubellus Hoffmeister (opens in a new tab) Download PDF for The transport of mineral and organic matter into the soil profile by Lumbricus rubellus Hoffmeister (opens in a new tab)

  6. Studies on rat gastrointestinal neuropeptide Y

    … was achieved using a HPLC with a μBondapak C₈ column and a 45-50% acetonitrile concentration gradient. A polyethylene glycol separation technique was used in conjunction with the HPLC purified tracer to improve assay conditions. Although many studies aimed at elucidating the actions of NPY have …

    ubc Repository record for Studies on rat gastrointestinal neuropeptide Y (opens in a new tab) Download PDF for Studies on rat gastrointestinal neuropeptide Y (opens in a new tab)

  7. A sensitive GLC-ECD method for determination of metoclopramide in biological fluids

    … rate: 40 ml/ min. A 1.8 m, 2 mm i . d . glass column packed with 3% OV-17 coated on Chromosorb W (80-100 mesh) was used. GLC/MS - The structure of the HFB derivative was elucidated by GLC-electron impact mass spectrometry. The following conditions were used: injection temperature: 250°C column …

    ubc Repository record for A sensitive GLC-ECD method for determination of metoclopramide in biological fluids (opens in a new tab) Download PDF for A sensitive GLC-ECD method for determination of metoclopramide in biological fluids (opens in a new tab)

  8. Koncepční řešení podvěsného dopravníku pro velkosériovou výrobu automobilů

    Tématem této bakalářské práce je podvěsný dopravník. Práce obsahuje rešerši o podvěsných dopravnících, technické zadání pro 3 okruhy a jejich zpracování.

    brno-tech Repository record for Koncepční řešení podvěsného dopravníku pro velkosériovou výrobu automobilů (opens in a new tab)