Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 55 for “"C-scan"”.
-
Neural Network Prediction of Ultimate Compression After Impact Loads in Graphite-Epoxy Coupons from Ultrasonic C-Scan Images
… 24-ply graphite-epoxy coupons from ultrasonic C-scan images. The 24-ply graphite-epoxy coupons were manufactured with bidirectional preimpregnated tape and cut into 21 coupons, 4 inches by 6 inches each. The coupons were impacted at known impact energies of 10, 12, 14, 16, 18, and 20 Joules in …
-
Advanced Projection Ultrasound Imaging with CMOS-based Sensor Array: Development, Characterization, and Potential Medical Applications
… of a projection imaging system. Three C-scan prototypes, which included prototypes #1, #2 and an ultrasound mammography system, were constructed. Systematic and Evaluative studies included ultrasound CT, 3-D ultrasound, and multi-modality investigations were also performed. Furthermore, a …
-
Damage assessment of a swirl glass mat reinforced polyurethane composite using nondestructive test methods
… samples were examined nondestructively, using C-scan ultrasonics and light-transmission microscopy (LTM). Additionally, selected samples that failed during the tests were further examined by scanning electron microscopy (SEM) to evaluate the extent of damage in the vicinity of the fracture …
-
Mapping totally-focused flaw signal variation introduced by interface curvature in ultrasonic array inspection
… Method (TFM) for performing ultrasonic C-scans of components with irregular and curved surfaces. Ultrasonic inspection depends on an understanding of the link between an ultrasonic indication and flaw size. Some existing methods at Rolls-Royce use target defects of a known size and metal …
-
Strain Rate Dependence And Impact Behavior Of Abs (acrylonitrile-Butadiene-Styrene) Amorphous Thermoplastic
… evaluation methods, such as ultrasonic C-Scan and laser scanning microscopy, were utilized to detect damaged areas and surface imperfections, respectively. The detected damaged areas by ultrasonic C-Scan were also compared to the numerically predicted damaged areas.
-
Real-Time 3D-Echokardiographie des Herzens : Validierung der in vitro Volumenbestimmung, Validierung der Flächenbestimmung an künstlichen Defekten, sowie Flächenbestimmung bei natürlichen Vorhofseptumdefekten
… 3,5 MHz-Schallkopf und mittels B- und <br>C-Scan vermessen wurden, ergab: <br>- Die RT3DE- Volumina stimmen mit den wahren Volumina sehr gut überein (mittl. <br>Abweichung 0,3% ± 2) und korrelieren ausgezeichnet (r= 0,99). Der B-Scan <br>überschätzt geringfügig (0,5% ± 0,2), der C-Scan …
-
Nondestructive inspection and characterization of complex engineering materials via ultrasound techniques.
… of an oblique-incidence through transmission c-scan ultrasound technique. As laminated composites are incorporated into new aircraft, there is an increased desire for nondestructive methods for not just damage inspections but also for characterizing the material properties of the part …
-
Nondestructive inspection of load induced damage in fiber reinforced polyphenylene sulfide
… nondestructive testing methods, including C-scan, ultrasonic attenuation, acoustic emission, X-ray radiography, and edge replication, were applied to study the damage developed under quasi-static tension loading of this material. The C-scan, edge replication, and X-ray radiography tests were …
-
Fatigue behaviour of a barely visible impact damaged carbon fibre reinforced epoxy laminate
… damage was characterized using ultrasonic C-scan and thermography. Residual strength testing revealed that the compressive static strength of the test specimens was reduced by over 50%. Digital image correlation was used to characterize the growth of damage and the local strain during …
-
The spatial cross-correlation coefficient as an ultrasonic detection statistic
… coefficients are calculated between A-scans digitized at adjacent measurement positions and can be formed into images that are similar to C-scan images. We also describe an approach for generating simulated acoustic noise with a spatial correlation coefficient distribution and maximum …
-
Impact damage resistance and tolerance of advanced composite material systems
… these materials. The damage area detected by C-scan is observed to develop linearly with the impact velocity for impact velocities higher than a threshold value. Brittle material systems have lower threshold velocities and higher damage area growth rates than toughened systems. The impact damage …
-
Intelligent Non-destructive Measurement and Evaluation Techniques for Aircraft Composites
… image reconstruction for ultrasonic C-scan, ultrasonic 3D reconstruction, and polynomial fitting techniques for infrared thermography inspection. These researches focus on the improvement and optimization of current ultrasonic testing and infrared thermography inspection. They are …
-
An investigation of stiffness reduction as an indicator of fatigue damage in graphite epoxy composites
… Nondestructive testing techniques such as C-scan and edge replication were also performed to aid in the observation of damage development. Results describe the response of each laminate orientation in tension-tension fatigue, including a record of changes in the stiffness properties at …
-
Ultrasonic stochastic localization of hidden discontinuities in composites using multimodal probability beliefs
… two-dimensions based on statistical data of A-Scans and C-Scans. Multiple experiments have been performed on carbon fiber reinforced plastics including artificial delaminations and porosity at different depths in the thickness of material. A probabilistic approach, which precisely localizes …
-
Computerized Ultrasonic Raytracing Model for C-scans of Solid Steel Bridge Pins
… the results of computerized ultrasonic C-scanning of solid steel bridge pins using a raytrace model. The raytrace model was developed to facilitate interpretation of data obtained from an ultrasonic C-scanning system for the Virginia Transportation Research Council (VTRC). The report …
-
Development of a Handheld Scanning Transducer Probe for Ultrasound Imaging
The scanning transducer technique is a simple and cost effective approach to achieve ultrasound imaging. By mechanically scanning a single-element transducer with a motor stage, the time-variant ultrasound field at an array of locations can be recorded for image reconstruction. When compared with …
-
Μελέτη της επαναληψιμότητας μετρήσεων τοπογραφικών συστημάτων του κερατοειδούς στην οφθαλμολογία
… Maps). Two topographic systems the TechnoMed C-Scan and the TOMEY Topographic Modeling System (TMS-2Ν) were examined to demonstrate our method. Results. Graphic representation of coefficient of variance offered a detailed representation of examination variability both in calibration surfaces and …
-
Synthesis, evaluation and machine learning integration of fire-retardant fiber composites for aviation industries
… and shear strength. Microscopic images, C-scan, and SEM results confirmed good bonding between matrix and fiber. Smoke density and toxicity test results were encouraging, demonstrating nearly no smoke formation and very little release of harmful gases because of the improved fire-shielding …
-
Nondestructive evaluation of layered ceramic materials using terahertz imaging
… signal amplitude variations in an experimental C-Scan image with the density of voids over slices of the abradable coating. In the second half of the work, an automated data processing procedure was developed for detecting embedded test flaws in a group of oxide/oxide ceramic matrix composites and …
-
Impact response of interleaved composite materials
… laminate did not show any ultrasonic C-scan indication up to an impact of 2.45 ft-lb. The increase of delamination with increasing impact energy was slower in the interleaved specimen. The eddy current method is not effective in detecting damage in the interleaved laminate because of the …
Page 1 of 3