Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 31 for “"C3F8"”

  1. Some Electrical Characteristics of C3F8 Electrode Systems

    This paper treats with corona discharges at normal pressure and at room temperature in C_3 F_3 and air with the following electrode systems: ¾” diameter sphere to 1 ¾” diameter plane, point to 1 ¾” diameter plane, point to point, 1” diameter sphere to 1” square plane, superimposed on a 1 ¾” …

    sdstate Repository record for Some Electrical Characteristics of C3F8 Electrode Systems (opens in a new tab)

  2. Bubble growth dynamics for C3F8 bubble chambers

    … perturbation method is applied to superheated C3F8 to describe the acoustic background discrimination achieved by the PICO experiment. We reproduced the delay in water and confirmed its occurrence in C3F8. We hypothesized that the delay can be used for optical background discrimination. …

    laurentian Repository record for Bubble growth dynamics for C3F8 bubble chambers (opens in a new tab)

  3. Dark Matter Limits from a 2L C3F8 Filled Bubble Chamber

    The PICO-2L C3F8 bubble chamber search for Weakly Interacting Massive Particle (WIMP) dark matter was operated in the SNOLAB underground laboratory at the same location as the previous CF3I filled COUPP-4kg detector. Neutron calibrations using photoneutron sources in C3F8 and CF3I filled …

    chicago Repository record for Dark Matter Limits from a 2L C3F8 Filled Bubble Chamber (opens in a new tab)

  4. RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI

    … considering the particular MR parameters of C3F8 by the following approaches: (i) Exploration of coil designs capable of imaging both proton (1H – 63.8 MHz at 1.5T) and fluorine (19F – 60.1 MHz at 1.5T) nuclei involved: 1. The novel use of microelectromechanical systems to switch a single …

    whiterose Repository record for RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI (opens in a new tab)

  5. Response of Superheated C3F8 and C2H2F4 to Nuclear and Electron Recoils: Applications to Dark Matter Detection

    … as part of this thesis, was operated using C3F8 and C2H2F4 (refrigerant R-134a) within its 25 c.c. active volume. These compounds are favored as WIMP scattering targets for dark matter direct detection. This thesis reports on high-statistics calibration studies from a C3F8 and R-134a filled …

    chicago Repository record for Response of Superheated C3F8 and C2H2F4 to Nuclear and Electron Recoils: Applications to Dark Matter Detection (opens in a new tab)

  6. Corona Induced Bond Cleavage in Gaseous Fluorocarbons

    … characteristics were obtained for the CF4 and C3F8 gases over a considerable period of time in the presence of additives. The substances used for additives were those for which there was existing evidence that they could function as corona inhibitors. Thus, additives showing an ability to act …

    sdstate Repository record for Corona Induced Bond Cleavage in Gaseous Fluorocarbons (opens in a new tab)

  7. Μελέτη επίδρασης υλικών επιπωματισμού στα ανατομικά και λειτουργικά αποτελέσματα ασθενών με αποκόλληση αμφιβληστροειδούς που υπεβλήθησαν σε υαλοειδεκτομή

    … Gas tamponade was performed using either C3F8 14% or SF6 20%. All participants underwent slit-lamp examination, fundoscopy, spectral domain-optical coherence tomography, optical coherence tomography angiography and completed the VFQ-25 Questionnaire at month 6 postoperatively. The fellow …

    greece Repository record for Μελέτη επίδρασης υλικών επιπωματισμού στα ανατομικά και λειτουργικά αποτελέσματα ασθενών με αποκόλληση αμφιβληστροειδούς που υπεβλήθησαν σε υαλοειδεκτομή (opens in a new tab)

  8. Thermo-dynamical measurements for ATLAS Inner Detector (evaporative cooling system)

    … (R116) C2F6 and Octafluoropropane(R218) C3F8 at differing ratios instead of just pure C3F8 coolant presently used. For this purpose, a new "blending" machine was assembled in the SR1 laboratory, with a new device an "on-line acoustic flow meter and fluorocarbon coolant mixture analyzer" …

    glasgow Repository record for Thermo-dynamical measurements for ATLAS Inner Detector (evaporative cooling system) (opens in a new tab)

  9. A comprehensive investigation of halogenated plasmas: from mechanistic studies to applications

    Octafluoropropane (C3F8) and octafluorocyclobutane (C4F8) plasmas were used to deposit thin fluorocarbon (FC) films on Si substrates. The effects of applied rf power (P), substrate position and pulsing the plasma on film composition and thickness were studied. Plasma parameters that limited ion …

    colostate Repository record for A comprehensive investigation of halogenated plasmas: from mechanistic studies to applications (opens in a new tab)

  10. <p>NANOFIBER REINFORCED EPOXY COMPOSITE</p>

    … composite. Two kinds of plasma treated fibers (C3F8, HMDSO) were studied in producing the composite samples. It is shown that the composites reinforced by surface modified VGCF exhibit marginally higher compressive strength and lower porosity compared to composites with unmodified fiber. The …

    ohiolink Repository record for <p>NANOFIBER REINFORCED EPOXY COMPOSITE</p> (opens in a new tab)

  11. Recovery of valuable products from polytetrafluoroethylene (PTFE) waste

    … the different products, namely C2F4, C2F6, C3F6, C3F8 and c-C4F8. Different conceptual reactors were designed and built for different tests on filled and unfilled PTFE. These included a laboratory scale Rotating-kiln Reactor for testing the depolymerisation properties in a horizontal reactor, a …

    nwu-za Repository record for Recovery of valuable products from polytetrafluoroethylene (PTFE) waste (opens in a new tab)

  12. Plasma modification of metal oxides and textiles: tailoring surface properties for improved gas sensor and protective clothing applications

    … and resuspension. These studies employed C3F8 and H2O(v) plasmas to treat four common lab coat materials. XPS and water contact angle goniometry confirm that the C3F8 plasma treatment increases the hydrophobicity of the fabrics and the H2O(v) plasma increases the wettability of most …

    colostate Repository record for Plasma modification of metal oxides and textiles: tailoring surface properties for improved gas sensor and protective clothing applications (opens in a new tab)

  13. Bubble formation and growth In superheated liquid bubble chambers

    … using a Lennard-Jones potential to model the C3F8 molecule. We also successfully triggered nucleation by low-mass high kinetic energy projectile from within the superheated liquid. This process mimics what is believed to occur in superheated liquid such as C3F8, which is used in PICO bubble …

    laurentian Repository record for Bubble formation and growth In superheated liquid bubble chambers (opens in a new tab)

  14. Σύνδρομο υαλοειδοαμφιβληστροειδικής έλξης: κλινική πορεία - θεραπεία

    … and tamponade (air, 20% SF6 or 12% C3F8) was used in 41 patients. Retinal breaks were identified intraoperatively in four patients. Regression analysis demonstrated that the preoperative BCVA was the only parameter affecting the postoperative visual outcome. CONCLUSION: In the …

    greece Repository record for Σύνδρομο υαλοειδοαμφιβληστροειδικής έλξης: κλινική πορεία - θεραπεία (opens in a new tab)

  15. Comparison of Electric Strength of Nitrogen and C4F8 Various Wave Shapes

    … Testing has been carried on with such gases as C3F8, C4F8, SF6, and NF3. These tests have been done in the areas of lightning impulses and 60 cycles. The next stop is to extend the work by using wave shapes between these two extremes and compare their breakdown strengths to the two extremes. …

    sdstate Repository record for Comparison of Electric Strength of Nitrogen and C4F8 Various Wave Shapes (opens in a new tab)

  16. The PICO-2L program: Towards Background-Free Dark Matter Direct Detection Using Bubble Chambers

    … a 2 litre bubble chamber filled with superheated C3F8 and over the next three years, conducted two separate WIMP-search experiments. The first run was conducted at 4 different energy thresholds ranging from 3.2 keV to 8.1 keV and a total of 12 candidate events were observed during a total exposure …

    queens Repository record for The PICO-2L program: Towards Background-Free Dark Matter Direct Detection Using Bubble Chambers (opens in a new tab)

  17. Packaging de composants grand gap haute température et haute tension

    … et leurs GWP faibles : l'octafluoropropane (C3F8) et l'octafluorocyclobutane (c-C4F8), l'azote (N2) faisant référence pour comparaison. Au préalable, une étude sur les céramiques les plus utilisées à haute température est réalisée. Cette étude montre un changement du mécanisme de conduction …

    star-france Repository record for Packaging de composants grand gap haute température et haute tension (opens in a new tab)

  18. Matériaux fluorés nanostructurés pour le stockage chimique du fluor moléculaire F2

    … qui utilisent des agents tels que CF4, C2F6, C3F8 ou NF3 comme sources de fluor atomique pour le nettoyage des enceintes et la gravure. De même, le cycle du combustible nucléaire implique des fluorations sous HF puis F2 pour la séparation isotopique et l'enrichissement de l'uranium. Leur …

    star-france Repository record for Matériaux fluorés nanostructurés pour le stockage chimique du fluor moléculaire F2 (opens in a new tab)

Page 1 of 2