Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 89 for “"CARDIAC RHYTHM"”.

  1. Safety of implantable cardiac rhythm management devices /

    … treatments, such as pacemakers (PM), implantable cardiac defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices, are used for numerous cardiac conditions. Cardiac rhythm management devices perform different functions, including monitoring for arrhythmias, bradycardia pacing, …

    vilnius Repository record for Safety of implantable cardiac rhythm management devices / (opens in a new tab)

  2. Exercise-Associated Cardiac Rhythm Disorders in Thoroughbred Racehorses

    Cardiac arrhythmias negatively impact horseracing through concerns for horse and jockey safety and welfare. The most clinically relevant rhythm disorders in Thoroughbred racehorses (TBs) are atrial fibrillation (AF), which typically causes poor performance, and fatal arrhythmias which precipitate …

    adelaide Repository record for Exercise-Associated Cardiac Rhythm Disorders in Thoroughbred Racehorses (opens in a new tab)

  3. Critical care nurses' knowledge of cardiac rhythm strips

    … ACLS-certified are able to accurately interpret cardiac rhythms. Patricia Benner's model of skill acquisition was used as the theoretical framework. Critical care nurses who are ACLS-certified are assumed to be in at least the competent level of skill acquisition; The sample was comprised of 99 …

    unlv Repository record for Critical care nurses' knowledge of cardiac rhythm strips (opens in a new tab) Download PDF for Critical care nurses' knowledge of cardiac rhythm strips (opens in a new tab)

  4. CARDIAC RHYTHM DURING MECHANICAL VENTILATION AND WEANING FROM VENTILATION

    … by heart rate variability [HRV]). Although cardiac dysrhythmias are an important manifestation of hemodynamic alterations, development of dysrhythmias during MV and weaning and subsequent impact on length of MV has received little attention. The purposes of this dissertation were to 1) …

    uky-thes Repository record for CARDIAC RHYTHM DURING MECHANICAL VENTILATION AND WEANING FROM VENTILATION (opens in a new tab)

  5. Automated Cardiac Rhythm Diagnosis for Electrophysiological Studies, an Enhanced Classifier Approach

    INTRODUCTION Heart function can be impaired by rhythm disturbances (cardiac arrhythmia), illustrated by electrocardiogram (ECG) recordings. Computerised arrhythmia diagnosis is well established for ECG’s but less for intracardiac electrophysiological (EP) testing. Accurate diagnosis is …

    city-london Download PDF for Automated Cardiac Rhythm Diagnosis for Electrophysiological Studies, an Enhanced Classifier Approach (opens in a new tab)

  6. Psychological Contributions to Exercise Associated Cardiac Rhythm Disturbances in the Standardbred Racehorse

    Psychogenic contributions to arrhythmogenesis reflecting autonomic changes are established in medical literature but not in the horse, despite the incidence of complex ventricular arrhythmia (CVA) and sudden cardiac death in the Standardbred racehorse. This study examined associations between …

    guelph Repository record for Psychological Contributions to Exercise Associated Cardiac Rhythm Disturbances in the Standardbred Racehorse (opens in a new tab) Embargoed until 2027-08-04

  7. The Paired-Like Homeodomain Transcription Factor 2 (PITX2) Regulates Atrial Metabolism and Cardiac Rhythm

    … fibrillation is the most common supraventricular cardiac arrhythmia, affecting 2-3% of Canadians with increased morbidity and mortality. There is a clear heritable component to atrial fibrillation, with the paired-like homeodomain transcription factor 2 (PITX2) identified as a strong genetic risk …

    sask Repository record for The Paired-Like Homeodomain Transcription Factor 2 (PITX2) Regulates Atrial Metabolism and Cardiac Rhythm (opens in a new tab)

  8. Universal Engineering Programmer – An In-House Development Tool for Developing and Testing Implantable Medical Devices in St. Jude Medical

    … device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In …

    calpoly Repository record for Universal Engineering Programmer – An In-House Development Tool for Developing and Testing Implantable Medical Devices in St. Jude Medical (opens in a new tab)

  9. STT Event Stream Feature to Assist Software Testing of Impantable Devices in St. Jude Medical

    … device functionality, engineers in the cardiac rhythm management industry use a patient simulator to ensure device functionality properly before device is tested with an animal or a human. The patient simulator is also used in the formal device product testing. In St. Jude Medical, a …

    calpoly Repository record for STT Event Stream Feature to Assist Software Testing of Impantable Devices in St. Jude Medical (opens in a new tab)

  10. Pharmacological action of atropine on cardiac muscle

    Does Atropine influence the cardiac rhythm and the power of the heart's contractions by direct action on its muscular tissue, and if so, to what extent and under what conditions? It is my purpose therefore in this work to determine the pharmacological action of atropine on cardiac muscle, using the …

    missouri Repository record for Pharmacological action of atropine on cardiac muscle (opens in a new tab)

  11. A machine learning framework for spatio-temporal cardiac assessment of echocardiographic cines

    … (echo) plays an important role in cardiac imaging and provides a non-invasive, low-cost, and widely available diagnostic tool for the comprehensive evaluation of cardiac structure and function. However, ultrasound image interpretation remains a challenge, particularly for the …

    ubc Repository record for A machine learning framework for spatio-temporal cardiac assessment of echocardiographic cines (opens in a new tab) Download PDF for A machine learning framework for spatio-temporal cardiac assessment of echocardiographic cines (opens in a new tab)

  12. Antikoaguliantų naudojimas implantuojant širdies ritmą reguliuojančius prietaisus /

    … of anticoagulation therapy during implantable cardiac rhythm management device procedures. Methods. Randomized controlled trials and observational studies in English language published between 2015 and 2022 were included in the literature review. Studies, which compared different management …

    vilnius Repository record for Antikoaguliantų naudojimas implantuojant širdies ritmą reguliuojančius prietaisus / (opens in a new tab)

  13. Implantuojamų elektrokardiogramos registravimo prietaisų panaudojimas sinkopių diagnostikai /

    … modalities. By continuously monitoring the cardiac rhythm over extended periods, ILR increases the likelihood of establishing a correlation between the recorded events and the cardiac rhythm. This feature enhances the diagnostic utility of ILR and renders them a valuable tool for clinicians …

    vilnius Repository record for Implantuojamų elektrokardiogramos registravimo prietaisų panaudojimas sinkopių diagnostikai / (opens in a new tab)

  14. Shocked: Confronting The Decision To Accept Or Decline An Implantable Cardioverter Defibrillator (ICD)

    Background And Aim: Primary cardiac rhythm management device (CRMD) provides potentially lifesaving treatment for people at risk of sudden cardiac death. Yet the enormity and uncertainty of benefits and harms present challenges for patient decision-making surrounding device implantation. There was …

    whiterose Download PDF for Shocked: Confronting The Decision To Accept Or Decline An Implantable Cardioverter Defibrillator (ICD) (opens in a new tab)

  15. Influence of Right Ventricular Leads of Cardiac Devices on Tricuspid Valve Function and Occurrence of Tricuspid Regurgitation

    … In Germany, many Pacemakers (PM) and cardiac rhythm devices are implanted at specialized clinics each year. However, the impact of right ventricular leads on the tricuspid valve (TV) function as well as possible effects on mortality are largely unexamined. Previous studies show …

    fu-berlin Repository record for Influence of Right Ventricular Leads of Cardiac Devices on Tricuspid Valve Function and Occurrence of Tricuspid Regurgitation (opens in a new tab)

Page 1 of 5