Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 117 for “"CBCT imaging"”

  1. Accuracy and Reliability of CBCT imaging for Assessing Adenoid Hypertrophy

    … and accuracy of cone-beam computed tomography (CBCT) for assessing adenoid size compared to nasoendoscopy (NE), 2) Influence of clinical experience on CBCT diagnosis. Methods: Four blinded evaluators reviewed randomized CBCT images. Adenoid size was graded on a 4-point scale for CBCT and NE (by …

    alberta Repository record for Accuracy and Reliability of CBCT imaging for Assessing Adenoid Hypertrophy (opens in a new tab)

  2. Sinus Pathology Detection in Panoramic Radiographs Verified by CBCT Imaging

    … dose compared to cone-beam computed tomography (CBCT). However, questions remain about their reliability in detecting various sinus pathologies. Objective: This study seeks to evaluate the diagnostic accuracy of PR for identifying maxillary sinus abnormalities, using CBCT and expert oral …

    temple Repository record for Sinus Pathology Detection in Panoramic Radiographs Verified by CBCT Imaging (opens in a new tab)

  3. Ratio of RME Appliance Expansion to Increase in Arch Perimeter Using CBCT Imaging

    Objective: This study measured CBCT images to determine if a consistent ratio exists between the quantifiable number of millimeters a cemented rapid palatal expansion appliance is opened and the subsequent increase in the arch perimeter obtained due to lateral expansion of the arch. Methods: The …

    loma-linda Repository record for Ratio of RME Appliance Expansion to Increase in Arch Perimeter Using CBCT Imaging (opens in a new tab)

  4. Posterior Cranial Base Growth and Development Changes as Assessed Through CBCT Imaging in Adolescents

    … (3D) cone beam computed tomography (CBCT). An adolescent population was then used to assess growth related dimensional changes of the previously selected landmarks. Methods: Systematic review was conducted via the PRISMA guidelines. Reliability and accuracy were assessed using CBCT’s …

    alberta Repository record for Posterior Cranial Base Growth and Development Changes as Assessed Through CBCT Imaging in Adolescents (opens in a new tab)

  5. Data acquisition modeling and hybrid coronary tree 3D reconstruction in C-arm CBCT imaging

    L'angiographie coronarienne RX (ou coronarographie) reste la modalité de référence permettant de déterminer avec précision le degré et le nombre de sténoses coronariennes ainsi que le nombre de vaisseaux atteints. L'objectif de ce travail de thèse de doctorat concerne l'amélioration de la …

    star-france Repository record for Data acquisition modeling and hybrid coronary tree 3D reconstruction in C-arm CBCT imaging (opens in a new tab)

  6. Cortical Bone Density and Thickness Assessment of Intraradicular Sites in Adolescent Patients Using CBCT Imaging

    … for the use of cone beam computed tomography (CBCT) in orthodontics has grown since it was first introduced and dentists are discovering new ways that 3D images enhance diagnosis and treatment planning. Evaluating bone quality and quantity can be measured as bone density and thickness in CBCT …

    unlv Repository record for Cortical Bone Density and Thickness Assessment of Intraradicular Sites in Adolescent Patients Using CBCT Imaging (opens in a new tab)

  7. Assessment of Measurement Accuracy in CBCT Imaging of Simulated Lesions With and Without Radiographic Phantoms

    … in dental cone-beam computed tomography (CBCT). This study sought to compare measurements obtained using standard subjective visual adjustments against an objective calibration protocol utilizing a physical radiographic phantom as a reference. Methods: An in vitro model utilizing fresh …

    iupui Repository record for Assessment of Measurement Accuracy in CBCT Imaging of Simulated Lesions With and Without Radiographic Phantoms (opens in a new tab)

  8. Anterior and Middle Cranial Base Growth and Development Changes as Assessed Through CBCT Imaging in Adolescents

    … adolescents with the use of landmarks. Methods: CBCTs of 10 dry skulls were used to assess reliability and accuracy of landmarks. Secondly, CBCTs of adolescents at two time points (19 months apart) were assessed for dimensional changes due to growth using the landmarks selected in the first step. …

    alberta Repository record for Anterior and Middle Cranial Base Growth and Development Changes as Assessed Through CBCT Imaging in Adolescents (opens in a new tab)

  9. Temporomandibular Joint Condylar/Fossa Positional Changes Post Herbst And Xbow Treatments In Adolescents Assessed Through CBCT Imaging

    … three groups (Herbst, Xbow, and control). Two CBCT images were taken for each patient, corresponding to pre-and post-treatment. The mandibular condyle and glenoid fossa position relative to the reference planes were assessed using Avizo© software using landmark to plane distance calculation. …

    alberta Repository record for Temporomandibular Joint Condylar/Fossa Positional Changes Post Herbst And Xbow Treatments In Adolescents Assessed Through CBCT Imaging (opens in a new tab)

  10. Beam Hardening and Scatter Artifact with Metal Objects Inside and Outside the Field of View in CBCT Imaging

    … left maxilla and imaged using Accuitomo 170 CBCT with limited FOV. Sixteen scans (7 with metal inside the FOV, 7 with metal outside the FOV, and two controls) were obtained. The artifacts were objectively evaluated by calculating the standard deviation (SD) of grayscale values using ImageJ …

    tamu Repository record for Beam Hardening and Scatter Artifact with Metal Objects Inside and Outside the Field of View in CBCT Imaging (opens in a new tab)

  11. Diagnosing Occult Radiocarpal Fractures in Aotearoa: What is the Current Detection Rate, and Which Patients Are Accessing Early CBCT Imaging?

    … injuries are common, and radiographic (X-ray) imaging remains the standard first-line diagnostic tool. However, its limited sensitivity for detecting carpal fractures can result in misdiagnosis, leading to delayed treatment, and prolonged recovery. Advancements in high-resolution imaging, …

    auckland-tech Repository record for Diagnosing Occult Radiocarpal Fractures in Aotearoa: What is the Current Detection Rate, and Which Patients Are Accessing Early CBCT Imaging? (opens in a new tab)

  12. Evaluation of a novel palatal suture maturation classification as assessed by CBCT imaging of a pre- and post-expansion treatment cohort

    … maturation stages, with accessible pre-expansion CBCTs. The retrospective observational longitudinal (cohort) study evaluated 63 pre-adolescent and adolescent patients aged 11-17 years old with full permanent dentition treated with tooth-borne RME appliances who have CBCTs records taken at T1 pre- …

    alberta Repository record for Evaluation of a novel palatal suture maturation classification as assessed by CBCT imaging of a pre- and post-expansion treatment cohort (opens in a new tab)

  13. Assessment of changes in the size of periapical radiolucencies 3-12 months post non-surgical root canal treatment using CBCT imaging: A pilot study

    … 3-12 months following root canal treatment using CBCT. Patients who had non-surgical root canal therapy (NSRCT) or non-surgical retreatment (ReTx) from July 30,2014 to August 19, 2015 with a periapical lesion of endodontic origin and received NSRCT or ReTx and had a pre-treatment or …

    vcu Repository record for Assessment of changes in the size of periapical radiolucencies 3-12 months post non-surgical root canal treatment using CBCT imaging: A pilot study (opens in a new tab)

  14. Accuracy and reliability of CBCT imaging for adenoid hypertrophy screening among a sample of oral maxillofacial radiologists and orthodontists and by an automated commercial imaging software

    … different dental specialists and a modern dental imaging software to evaluate adenoidal hypertrophy compared with the current reference standard diagnosis by an Otorhinolaryngologist – Head and Neck Surgeon (OHNS) using Nasopharyngoscopy (NP). The specific questions to be answered were: (1) the …

    alberta Repository record for Accuracy and reliability of CBCT imaging for adenoid hypertrophy screening among a sample of oral maxillofacial radiologists and orthodontists and by an automated commercial imaging software (opens in a new tab)

  15. Outcome of Endodontic Microsurgery: Success and Survival Rates at Virginia Commonwealth University

    … 2-dimensional PA radiographs and 3 dimensional CBCT imaging. Methods: Patient records were pooled from graduate resident cases completed at Virginia Commonwealth University in the Graduate Endodontic Clinic between the years 2010 to 2020. Cases were identified using the CDT codes and a key word …

    vcu Repository record for Outcome of Endodontic Microsurgery: Success and Survival Rates at Virginia Commonwealth University (opens in a new tab)

  16. Generative AI for cone-beam CT dose reduction and intensity correction in adaptive radiotherapy

    … (IGRT), cone-beam computed tomography (CBCT) is used to align patients in the treatment position. CBCT scans administer radiation exposure and subject patients to secondary cancer risk. However, lowering CBCT imaging dose continues to be challenging as the image quality degrades. In …

    lmu-germany Repository record for Generative AI for cone-beam CT dose reduction and intensity correction in adaptive radiotherapy (opens in a new tab)

  17. INVESTIGATION OF OPTIMIZATION-BASED ALGORITHMS FOR TOMOGRAPHIC IMAGE RECONSTRUCTION

    Among all tomographic imaging devices, X-ray cone-beam computed tomography (CBCT) and positron emission tomography are two important tools used widely in numerous medical imaging applications, and both have enjoyed tremendous progress in both hardware and reconstruction algorithm development in the …

    chicago Repository record for INVESTIGATION OF OPTIMIZATION-BASED ALGORITHMS FOR TOMOGRAPHIC IMAGE RECONSTRUCTION (opens in a new tab)

  18. A combination of motion-compensated cone-beam computed tomography iame reconstruction and electrical impedance tomography

    Cone-beam computed tomography (CBCT) is an imaging technique used in conjunction with radiation therapy. CBCT is used to verify the position of tumours just prior to radiation treatment session. The accuracy of the radiation treatment of thoracic and upper abdominal tumours is heavily affected by …

    bath Repository record for A combination of motion-compensated cone-beam computed tomography iame reconstruction and electrical impedance tomography (opens in a new tab)

  19. Reliability of upper pharyngeal airway assessment using dental CBCT

    … Upper airway analysis is an often-cited use of CBCT imaging in orthodontics, however the reliability of airway measurements using this technology is not fully understood. The purpose of this study was to determine the intra-examiner and inter-examiner reliability of the complete process of …

    ubc Repository record for Reliability of upper pharyngeal airway assessment using dental CBCT (opens in a new tab)

  20. A classification of maxillary premolar sockets in relation to the osseous housing for immediate implant placement

    … and evaluation of the varying morphologies using CBCT imaging. Selection criteria included dentulous patients ages 15-85 that had CBCT imaging taken for varying treatment. A total of 400 maxillary premolars were classified by their root morphology as Type I (two-rooted premolar with interradicular …

    bu Repository record for A classification of maxillary premolar sockets in relation to the osseous housing for immediate implant placement (opens in a new tab)

Page 1 of 6