Showing 1 to 20 of 37 for “"CFST"”.
-
Inelastic Behavior of Direct RC Column to CFST Pile Connections
Concrete filled steel tubes (CFSTs) are a composite structural component consisting of a steel tubewith concrete infill. Prior research has shown that CFST structural elements have greater strength and stiffness than typical reinforced concrete structural elements of similar size, result in …
-
Design Expressions and Dynamic Evaluation of CFST Bridges Subjected to Seismic Hazards
Concrete filled steel tubes (CFSTs) consist of a steel tube with concrete infill. CFST columns offer an effcient and economical alternative to conventional reinforced concrete bridge columns, in that CFST columns can offer larger strength and stiffness and facilitate rapid construction. The first …
-
Nondeterministic long-term behavior and stability analysis of concrete-filled steel tubular (CFST) structures with uncertainty
Structures with concrete-filled steel tubular (CFST) sections have been widely accepted and rapidly used owing to its advantageous structural style. However, a notable drawback of CFST members is the time-dependent deformation caused by the creep of the inner concrete. In order to maintain a …
-
Long-term analysis of structural behaviour and stability of concrete-filled steel tubular arches
… and buckling of a concrete-filled steel tubular (CFST) arch under sustained loading are very much related to creep and shrinkage of its concrete core. The creep and shrinkage of the concrete core will produce time-dependent structural deformations and change equilibrium configuration of the CFST …
-
Nonlinear Analysis of Rectangular Concrete-Filled Steel Tubular Columns at Elevated Temperatures
… thin-walled concrete-filled steel tubular (CFST) slender columns under axial and eccentric loads may undergo local and global interaction buckling when exposed to fire. Computational studies on the fire and post-fire behavior of rectangular short and slender CFST columns including local …
-
The behaviour and design of demountable connections to promote the reduction and reuse of structural steel in steel and composite buildings
… connection for concrete-filled steel tubular (CFST) columns, through which the CFST columns can be readily dismantled at the end of their service life. For the proposed demountable connection, a number of blind bolts are utilised to connect four separate side-plates with the CFST columns. In …
-
Thermal Stability of Concrete and Concrete-Filled Steel Tubular Arches
… popularity of concrete-filled steel tubular (CFST) arch bridges. Hence, due to the inherent complex structural function of arches when coupled with the increasing construction of CFST arches, research into the response and stability of CFST arches under all possible environmental conditions is …
-
Fire Resistance of Ultra-High Strength Concrete Filled Steel Tubular Columns
… has been done on concrete filled steel tubular (CFST) columns and design codes are available for fire resistant design, guideline of high strength steel (HSS) and UHSC on CFST is not available. The present research aims to extend the design codes by investigating the behavior of high strength …
-
Nonlinear inelastic analysis of concrete-filled steel tubular slender beam-columns
… thin-walled concrete-filled steel tubular (CFST) slender beam-columns may undergo local and global buckling when subjected to biaxial loads, preloads or cyclic loading. The local buckling effects of steel tube walls under stress gradients have not been considered in existing numerical models …
-
Seismic Behavior of concrete filled steel Tubular Built-up columns
With the advantages of CFST built-up columns, including the higher confinement in the concrete, delay of the steel local buckling, higher compressive and flexural strength, earthquake and fire resistance, rapid construction, savings in the construction costs, etc. CFST built-up columns are …
-
Numerical and experimental research on the fire resistance of composite columns with steel sections embedded in concrete and high strength materials
… pilares tubulares de acero rellenos de hormigón (CFST) son un tipo de elementos estructurales mixtos que han ganado popularidad recientemente debido a su excelente comportamiento estructural y al uso racional de los materiales en su fabricación. Con la introducción de un perfil de acero dentro de …
-
Local Buckling Restraining Behavior Of Concrete-Filled Steel Tubular Columns Under Seismic Loads
… consist of concrete-filled steel tubular (CFST) columns have more benefits than ordinary reinforced concrete and steel systems. The CFST column increases earthquake resistant capabilities due to the concrete filling inside the steel tubes and are ideal for buildings subjected to large …
-
Vicarious Traumatization, Secondary Traumatic Stress, and Burnout in Sexual Assault and Domestic Violence Agency Staff and Volunteers
… Fatigue Self-test for Psychotherapists [CFST]) combines PTSD and burnout symptomatology explaining sudden adverse reactions to survivors. Burnout (BO; Maslach Burnout Inventory [MBI]), links emotional exhaustion, depersonalization, and deficient personal accomplishment to inadequate …
-
Structural Behaviour of Concrete Filled Steel Tubes With High Strength Materials.
… steel (HSS), stub concrete filled steel tube (CFST) columns, CFST beams, and slender CFST beam-columns. For evaluation, test results were compared with Eurocode 4 predictions. It was found that ultra-high resistance could be achieved. Therefore, they are most suitable to be applied in high-rise …
-
Fire Design of Concrete Filled Steel Tube Continuous Column Subjected to Concentric or Eccentric Axial Loading
… for concrete filled steel tubular (CFST) columns in fire are based on the results of experimental standard fire testing of CFST members where the same temperature is applied to the column over the full column height. However, this is not representative of a CFST column in a typical …
-
The Lateral and Post-Impact Residual Lateral Strength of Reinforced Concrete Columns
… From these tests it was determined that the CFST specimens exhibited both the largest lateral and residual lateral capacities of 37.37 kN and 40.17 kN, respectively. The CFST member had the highest retention of lateral load capacity for both low and high impact energy, retaining 75% and 107% …
-
Axial load capacity of circular steel tube columns filled with high strength concrete
… Steel Tube columns using High Strength Concrete (CFST-HSC). Emphasis is drawn to the enhanced axial capacity of short columns attributed to the lateral confinement of the concrete infill provided by the steel encasement. The degree of confinement has been found to be dependent on several geometric …
-
The behaviour of composite beam-to-column flush end plate connections using blind bolts
… achieved by using concrete-filled steel tubular (CFST) columns in multi-storey construction have been appreciated for decades. Tubular sections are more effective than open sections due to higher load carrying capacity, superior seismic capacity, improved ductility and fire resistance. However, …
-
Blast Resistance of Steel-Concrete Composite Structures
… behaviour of concrete filled steel tubular (CFST) columns subject to blast loading. The proposed approach will possess a closed form solution approach and the capability to analyse a structure, which respond both in flexural as well as in shear. The thesis will also study the blast resistant …
-
Efeito do silício no desenvolvimento da mancha marrom do trigo: componentes de resistência e respostas fisiológicas e bioquímicas
… de compostos fenólicos solúveis totais (CFST), a concentração de derivados da lignina-ácido tioglicólico (LATG), e a atividade das enzimas quitinases (QUI), peroxidades (POX) e polifenoloxidases (PFO). Neste estudo verificou-se que a concentração foliar de Si foi 90,5% superior em plantas …
Page 1 of 2