Showing 1 to 20 of 45 for “"CHROMATOGRAPHY COLUMNS"”.

  1. Semi-Packed Micro Gas Chromatography Columns

    Separation of complex gaseous mixtures using gas chromatography (GC) is an important step in analytical systems for environmental monitoring, medical diagnosis, and forensic science. Due to its high resolving power, analysis speed, and small sample size, GC, has become the premier technique for …

    vt Repository record for Semi-Packed Micro Gas Chromatography Columns (opens in a new tab)

  2. Density Modulated Semi-Packed Micro Gas Chromatography Columns

    With the continued evolution of MEMS-based gas chromatography, the drive to develop new standalone systems with lower power consumptions and higher portability has increased. However, with improvements come tradeoffs, and trying to reduce the pressure drop requirements of previously reported …

    vt Repository record for Density Modulated Semi-Packed Micro Gas Chromatography Columns (opens in a new tab)

  3. Design, Fabrication, and Evaluation of Micro Gas Chromatography Columns

    … of these developments allows creating microcolumns with performance comparable to commercial fused silicon columns.

    uiuc Repository record for Design, Fabrication, and Evaluation of Micro Gas Chromatography Columns (opens in a new tab)

  4. Studies of a DNA modification methyltransferase from Rhodobacter sphaeroides

    … cloned and sequenced. The purification used four chromatography columns, and yielded up to 100 $\mu$g of enzyme. M$\cdot$RsrI was overexpressed in E. coli and the yield of the purification improved by about 100-fold with respect to that from R. sphaeroides.

    uiuc Repository record for Studies of a DNA modification methyltransferase from Rhodobacter sphaeroides (opens in a new tab)

  5. Microbial transport through porous media: The effect of hydraulic conductivity and injection velocity

    … through porous media was investigated. Glass chromatography columns were packed separately with clean quartz sand of two diameters (0.368 mm or 0.240 mm) and two hydraulic conductivities (1.37 $\times$ 10$\sp{-1}$ cm/sec and 3.65 $\times$ 10$\sp{-2}$ cm/sec respectively). Three injection …

    rice Repository record for Microbial transport through porous media: The effect of hydraulic conductivity and injection velocity (opens in a new tab)

  6. Identification and Quantitation of Cannabinoid Solute-Column Interactions Using the Hydrophobic-Subtraction Model to Predict Separation in High-Performance Liquid Chromatography

    … for identification of similar and orthogonal chromatography columns since its inception in 2002 but only had limited uses as a predictive tool. Recent refinement of the model has improved the prediction accuracy to a level that offers promise for use in high-performance liquid chromatography …

    ecu Repository record for Identification and Quantitation of Cannabinoid Solute-Column Interactions Using the Hydrophobic-Subtraction Model to Predict Separation in High-Performance Liquid Chromatography (opens in a new tab)

  7. Application of soil mechanics and the finite element method (FEM) to High Performance Liquid Chromatography (HPLC) columns

    <p>The efficiency of High Performance Liquid Chromatography columns is often reduced due to radial variations of the density or void ratio of the silica packing material. This heterogeneity is due to wall friction effects during column preparation, and although the friction reduces the column …

    ut-knoxville Repository record for Application of soil mechanics and the finite element method (FEM) to High Performance Liquid Chromatography (HPLC) columns (opens in a new tab)

  8. Non-medical applications of imaging techniques : multi-dimensional NMR imaging

    … explored in three different areas of interest: Chromatography columns. Porous rock samples and Wood samples. A variety of NMR imaging sequences have been used to study some interesting and challenging features of these systems which clearly extends the scope of NMR imaging science.

    ubc Repository record for Non-medical applications of imaging techniques : multi-dimensional NMR imaging (opens in a new tab) Download PDF for Non-medical applications of imaging techniques : multi-dimensional NMR imaging (opens in a new tab)

  9. Optimization and nonlinear model predictive control of some simulated moving bed process variants

    … non-conventional arrangements of the train of chromatography columns that make up the SMB technology. Some of the most relevant and popular are the ModiCon and the VariCol processes, obtained by the periodic modulations of feed concentration and the length of arrangements of columns. …

    brazil-uerj Repository record for Optimization and nonlinear model predictive control of some simulated moving bed process variants (opens in a new tab)

  10. Optimization of Downstream Purification of Lucentis

    … The base case consisted of using a series of chromatography columns including anion exchange, cation exchange, and hydrophobic interaction chromatography (TOSOH Bioscience) resins followed by a 30 kDa tangential flow filtration (TFF) cassette (Pall Corp). Alternative case 1 consisted of a …

    unr Repository record for Optimization of Downstream Purification of Lucentis (opens in a new tab)

  11. MEMS-Based Micro Gas Chromatography: Design, Fabrication and Characterization

    … of high performance MEMS-based micro gas chromatography columns having wide range of applications in the pharmaceutical industry, environmental monitoring, petroleum distillation, clinical chemistry, and food processing. The first part of this work describes different approaches to achieve …

    vt Repository record for MEMS-Based Micro Gas Chromatography: Design, Fabrication and Characterization (opens in a new tab)

  12. MALDI MASS SPECTROMETRY BASED ASSAYS FOR SCREENING AMINOGLYCOSIDE KINASES

    … the fabrication of sol-gel derived bioaffinity chromatography columns. The MS-based kinase assays developed herein are highly amenable to high throughput screening, and have the potential to be extended to other important therapeutic targets.</p>

    mcmaster Repository record for MALDI MASS SPECTROMETRY BASED ASSAYS FOR SCREENING AMINOGLYCOSIDE KINASES (opens in a new tab)

  13. Molecularly imprinted polymers : rational design, controlled synthesis and novel applications

    … analytical method, Molecularly Imprinted Liquid Chromatography-Tandem Mass Spectrometry (MILC-MS/MS) for the detection of ketamine in hair. A key requirement was the production of ketamine imprinted polymer particulates in an appropriate physical format for the direct packing of the imprinted …

    strathclyde Repository record for Molecularly imprinted polymers : rational design, controlled synthesis and novel applications (opens in a new tab)

  14. BINDING KINETICS INVESTIGATION OF A PEPTIDE FRAGMENT OF THE PSYCHIATRIC RISK PROTEIN, DISC1, TO THE KINASE GSK3β

    … a series of affinity and ion exchange liquid chromatography columns. This process was optimized to obtain GSK3β with a purity level of 80% to use in subsequent studies. Binding interaction studies using surface plasmon resonance technology were conducted to determine the suspected binding site …

    sask Repository record for BINDING KINETICS INVESTIGATION OF A PEPTIDE FRAGMENT OF THE PSYCHIATRIC RISK PROTEIN, DISC1, TO THE KINASE GSK3β (opens in a new tab)

  15. Application of an Ionic Liquid Column to the Analysis of Flavor and Fragrance Ingredients

    … (polyethylene glycol/wax) stationary phase gas chromatography columns pose challenges for flavor and fragrance analysis particularly in regards to thermal instability at high temperatures, degradation when exposed to water, unchanging selectivity, and relatively short shelf lives. Recently, …

    shu-thes Repository record for Application of an Ionic Liquid Column to the Analysis of Flavor and Fragrance Ingredients (opens in a new tab)

  16. Use of small extracellular vesicles for diagnosis of Mycoplasma bovis : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science (MSc) in Genetics at Massey University, Manawatū, New Zealand

    … within bioreactor flasks. Using Size Exclusion Chromatography columns, sEVs were isolated from the harvests of the bioreactor flasks. Liquid Chromatography Tandem Mass Spectrometry assessed the sEV proteome to compare differences created by M. bovis infection. Results: Infection was indicated by …

    massey Repository record for Use of small extracellular vesicles for diagnosis of Mycoplasma bovis : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science (MSc) in Genetics at Massey University, Manawatū, New Zealand (opens in a new tab)

  17. Custom affinity chromatography : development of a novel platform for rapid creation and validation of affinity media using DNA aptamer based ligands

    … DSP platforms is the use of protein A affinity chromatography to capture and purify the product directly from clarified culture supernatants. Unfortunately, effective ligands for affinity capture of non-mAb biologics are generally not available. But this could change through the development of a …

    ubc Repository record for Custom affinity chromatography : development of a novel platform for rapid creation and validation of affinity media using DNA aptamer based ligands (opens in a new tab) Download PDF for Custom affinity chromatography : development of a novel platform for rapid creation and validation of affinity media using DNA aptamer based ligands (opens in a new tab)

  18. High Flow Air Sampler for Rapid Analysis of Volatile and Semi-Volatile Organic Compounds

    … constructed by bundling analytical capillary gas chromatography columns together in parallel. As low as single digit ppt detection limits were reached in less than 25 min with this trap, and as high as 8.0 L/min flow rate was sampled. The simple and compact multi-capillary trap could be easily …

    byu Repository record for High Flow Air Sampler for Rapid Analysis of Volatile and Semi-Volatile Organic Compounds (opens in a new tab) Download PDF for High Flow Air Sampler for Rapid Analysis of Volatile and Semi-Volatile Organic Compounds (opens in a new tab)

Page 1 of 3