Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 26 for “"CIED"”.
-
A randomized trial of non-fasting vs. fasting for cardiac implantable electronic device procedures (Fast-CIED Study)
… such as cardiac implantable electronic device (CIED) procedures for 4-6 h since their inceptions. However, there is no data available on safety and efficacy of a non-fasting strategy for these procedures. Strict fasting restrictions may be difficult for patients to abide by, and might even be …
-
Clinical outcomes associated with cardiac implantable electronic devices
… use of cardiac implantable electronic devices (CIEDs) has been increased dramatically in term of numbers as the broadening indications, not only for bradycardia management, but also for treating ventricular arrhythmias and preventing sudden cardiac death. Despite the undeniable benefit of CIED …
-
Living with a Cardiac Implantable Electronic Device: A Multimethod Exploration of Patients’ Psychosocial Experiences
… Cardiac implantable electronic devices (CIEDs), including permanent pacemakers (PPMs), implantable cardioverter-defibrillators (ICDs), and cardiac resynchronisation therapy (CRT) devices, are potentially life-saving treatments for patients with cardiovascular diseases such as arrhythmias …
-
Expanding Magnetic Resonance Imaging Access for Patients with Cardiovascular Implantable Electronic Devices
… cardiovascular implantable electronic devices (CIEDs), which lack magnetic resonance imaging (MRI) components, are unable to undergo MRI. Context. The Heart Rhythm Society guidelines for patient device management and Centers for Medicare and Medicaid Services requirements for persons with …
-
Prognostische Wertigkeit der Herzfrequenz in Abhängigkeit von implantierten Devices bei akuter Herzinsuffizienz: Ergebnisse des prospektiven AHF-Registers Würzburg
… a cardiovascular implantable electronic device (CIED), is associated with worse prognosis during and after an episode of acutely decompensated heart failure (AHF). Methods and Results Six hundred and twenty-three patients participating in an ongoing prospective cohort study that phenotypes and …
-
Patienten mit Herzschrittmachern und Kardioverter-Defibrillatoren in der Strahlentherapie
… kardial implantierten elektronischen Geräten (CIED, „cardiac implantable electronic device“) ein erhöhtes Sicherheitsrisiko darstellen. Zur Minimierung dieses Risikos wurde 2012 durch die Abteilungen für Kardiologie, Strahlentherapie und Anästhesie der Charité – Universitätsmedizin Berlin ein …
-
Evaluierung der Sicherheit der kurzfristig unterbrochenen Therapie mit Apixaban, Rivaroxaban und Dabigatran hinsichtlich Blutungskomplikationen nach CIED-Implantationen oder ähnlichen Prozeduren, im Vergleich zu Phenprocoumon
… implantierbaren elektronischen Devices (CIED), Aggregataustausches oder ähnlichen Prozeduren unterziehen, werden antikoaguliert. Die Sicherheit der perioperativen kontinuierlichen Gabe von Vitamin-K-Antagonisten (VKA) wurde in mehreren Studien untersucht und im Vergleich zur …
-
Analysis of Alternative Convoy Route Patrol Procedures for Countering Improvised Explosive Devices Deployed During Asymmetric Warfare in Afghanistan-like Rural Settings
… done on Counter Improvised Explosive Device (CIED) procedures. This paper explores the potential of CIED procedures as a casualty reduction mechanism by comparing two observed tactical procedures used in patrolling convoy routes.
-
Möglichkeiten der modernen kardialen Device-Therapie – von der Diagnose bis über den Tod hinaus
… und die Herzinsuffizienz. Diagnostische CIED machen wichtige Therapieentscheidungen möglich, nicht nur innerhalb der Gerätemedizin, sondern auch bezüglich diverser anderer Ansatzpunkte wie Medikation oder invasive Therapien. Der BioMonitor 2-AF (Biotronik) hat sich dabei als …
-
Safety of implantable cardiac rhythm management devices /
… tachyarrhythmias. Estimating the exact rate of CIED infections is challenging due to varying definitions, differences in patient populations, and the discrepancies between retrospective and prospective study rates. CIED infections typically occur through two main mechanisms. The most common is …
-
Predicting the Severity of Cardiac Implantable Electronic Device Infection with a Desirability of Outcome Ranking Scale: a secondary analysis of the PADIT Trial
… for cardiac implantable electronic device (CIED) infection predict whether an infection occurs and often collapse infections of differing severity. The Desirability of Outcome Ranking (DOOR) framework ranks each patient's overall outcome on an ordered scale but has only been used to compare …
-
Strengthening patient safety in radiation oncology: a nursing-led protocol for monitoring patients with cardiovascular implantable electronic devices
… cardiovascular implantable electronic devices (CIEDs) undergoing radiation therapy are at increased risk for device malfunction. Inconsistent communication, unclear role delineation, and lack of standardized procedures contribute to gaps in monitoring and follow-up, increasing the potential for …
-
Comprehensive evaluation of clinical care in patients with cardiac implanted electronic devices and arrhythmias: action towards improved workflow and outcomes
… with a Cardiac Implantable Electronic Device (CIED). Second, to determine optimal CIED selection for patients requiring continuous heart rhythm monitoring. Last, to define the utility of modern digital technology for heart rhythm assessment with a focus on atrial fibrillation (AF) screening. …
-
Single Center Erfahrung mit der Laser-Extraktion von Herzschrittmacher- und Kardioverter-Defibrillator-Sonden
… implantierbaren elektronischen Geräten (CIED) steigt auch die Anzahl der Komplikationen, die mit einem chirurgischen Zweiteingriff einhergehen. Nicht selten müssen die vorhandenen Sonden dabei extrahiert bzw. explantiert werden. Allein in Deutschland wurden laut Jahresbericht 2018 des …
-
Advancements in Magnetic Resonance Image Guided Radiotherapy
… Similarly, cardiac implanted electronic devices (CIEDs) result in magnetic susceptibility artifacts primarily due to ferromagnetic components. These artifacts manifest as banding artifacts in bSSFP images and make tracking structures in or near the heart challenging during treatment imaging. The …
-
The Influence of Exercise Training on Cardiovascular Health Outcomes in Adults with Cardiac Implantable Electronic Devices
… with cardiac implantable electronic devices (CIEDs). Study 1 retrospectively examined the changes in physical (e.g., cardiorespiratory fitness [CRF]), and mental health (e.g., anxiety levels) outcomes in patients with CIEDs completing an exercise-based cardiovascular rehabilitation (CR) …
-
Clinical Decision Support Algorithm for Prediction of Postoperative Atrial Fibrillation Following Coronary Artery Bypass Grafting
… with cardiac implantable electronic devices (CIED), and 3 patients with no CABG (valve replacement only). POAF was exhibited by 54 (34%) of patients. Factors significantly associated (P<0.05) with POAF were longer postoperative hospital stay, advanced age, larger left atrial (LA) volume, …
-
Perioperative Blutungskomplikationen bei Prozeduren mit kardialen implantierbaren elektronischen Devices: Ein Vergleich von Vitamin-K Antagonisten und NOAKs
… wurden die Informationen von Patienten mit einer CIED-Prozedur und gleichzeitiger perioperativer Antikoagulation im Zeitraum von Februar 2013 bis Oktober 2017 erfasst. Es wurden verschiedene Blutungs- und thromboembolische Komplikationen als primäre – und sekundäre Endpunkte festgelegt. Für die …
-
Transvenous lead extraction in a single centre: 20 year experience and long term follow up
… for cardiac implantable electronic devices (CIED’s) continue to expand. Increases in the number of devices implanted have resulted in an increased incidence of complications. These complications sometime require extraction of CIED leads for definitive treatment. I explore the indications, …
-
Propriedades físico-químicas e pigmentação coronária causada por cimentos biocerâmicos : estudo in vitro e ex vivo
… Zahnfabrik, Bad Säckingen, Germany) and CIELab, CIED 2000 and WID indexes were calculated to compare baseline tooth color with color measurements recorded after 24h, 30, 45 and 180 days. Tooth dicoloration was compared amongst the experimental groups in the four simulated clinical situations. …
Page 1 of 2