Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 115 for “"CIMS"”.
-
PLTW/CIMS Workcell Design
Not included.
-
Studies of current-perpendicular-to-plane magnetoresistance (CPP-MR) and current-induced magnetization switching(CIMS)
Thesis (Ph. D.)--Michigan State University. Department of Physics and Astronomy, 2005
-
New particle formation: sulfuric acid and amine Chemical nucleation photochemical reaction chamber studies and the laboratory cluster-CIMS.
… Chemical Ionization Mass Spectrometer (cluster-CIMS) has been developed, in collaboration with colleagues at the National Center for Atmospheric Research, to characterize homogeneously nucleated molecular clusters produced in a controlled laboratory environment. The cluster-CIMS gently ionizes …
-
Social class: the role of class identity management strategies in higher education
… role of class identity management strategies (CIMS). Such strategies are utilized among university students from working-class backgrounds in response to status devaluation. Four commonly observed CIMS in the university context are outlined: (1) desire to change, (2) assimilation, (3) hiding, …
-
Use of chemical ionization mass spectrometry for study of photochemical properties: ketone photolysis quantum yields
… mass spectrometer with iodide reagent ions (I-CIMS) and wide band light source instrument design, which was used to measure the quantum yield for CH3C(O) from acetone photolysis, through measurement of CH3C(O)O2. Acetone is the most abundant oxygenated organic gas in the troposphere and its …
-
Connecting our nation's Crisis Information Management Systems
… Crisis Information Management Systems (CIMS) to integrate situational awareness, notification and disaster assessment tools utilized in Emergency Operation Centers (EOC)s and to eliminate separate stovepipe communications. In February 2004, the Department of Homeland Security (DHS) …
-
New York City Fire Department chief officer's evaluation of the citywide incident management system as it pertains to interagency emergency response
… created the Citywide Incident Management System (CIMS) to address these shortcomings. The goal of this research is to provide an evaluation of CIMS several years after implementation; has it changed emergency response in New York City or are the same problems occurring? A survey of the FDNY chief …
-
Concentração inibitória mínima de vancomicina para staphylococcus sp. coagulase negativa resistente à meticilina : comparação entre os métodos de microdiluição em caldo e etest e correlação com falha terapêutica em pacientes com bacteremia
… com concentrações inibitórias mínimas (CIMs) próximas do limite do ponto de corte de suscetibilidade, conforme critérios do CLSI, indicando falha terapêutica. Entretanto, existem poucos estudos à respeito dos Staphylococcus sp. coagulase negativa resistentes à meticilina (SCoNRM). …
-
Multiplicative factorization of multi-valued NIN-AND tree causal models
… number of causes. Causal independence models (CIMs) are proposed to tackle this issue by exploiting causal independency among variables. However CIMs are not directly utilizable by common inference algorithms including lazy propagation. Multiplicative factorization (MF) is proposed as an …
-
Development, characterization, and deployment of a high-resolution time-of-flight chemical ionization mass spectrometer (HR-TOF-CIMS) for the detection of carboxylic acids and trace-gas species in the troposphere
… chemical ionization mass spectrometers (HR-TOF-CIMS) for gas-phase measurements is presented. Recent literature detailing the description of the HR-TOF-CIMS is critically evaluated and put into the context of the historical literature. The development of the HR-TOF-CIMS with reagent ion …
-
A sensitive laser-induced fluorescence system for the detection of trace level sulfur dioxide in the remote troposphere
… iodide chemical ionisation mass spectrometer (I−CIMS). Given their limits of detection (LoD, 3 σ) of 0.07, 0.4 and 2 ppb at 10 seconds for the LIF, PF and I−CIMS respectively, the percentage of data below their LoDs across the three flights were 9, 91 and 98 % respectively. Therefore, a …
-
Transition Pathways and Capabilities of Climate-Induced Migrants: The Case of Ready-Made Garment Workers in Bangladesh
… investigates how climate-induced migrants (CIMs) navigate their transitions into urban life, focusing particularly on their efforts to rebuild livelihoods and pursue stability after displacement due to environmental and climatic disasters. It critically analyses the multi-stage transitions …
-
Prevalência da concentração inibitória mínima elevada da vancomicina e a relação desta com o desfecho de pacientes com pneumonia causada por Staphylococcus aureus meticilina resistentes
… O objetivo deste estudo foi avaliar as CIMs para vancomicina em pacientes com diagnóstico de pneumonia por MRSA, descrever a relação entre a CIM da vancomicina obtido por Etest® e microdiluição em caldo com mortalidade em 30 dias em pacientes com pneumonia por MRSA internados em um …
-
Reactions of Bromide Ions with Atmospheric Trace Gases and Aerosols
… Br- as a chemical ionization mass spectrometry (CIMS) reagent ion for the detection and measurement of both atmospheric trace gases and aerosol species. The primary goals of this study are to obtain fast, very sensitive measurements of nitrate and sulfate and to ascertain if gas phase PAN and …
-
Charge and spin transport through magnetic molecules
… to the current-induced magnetic switching (CIMS) phenomenon, known from other magnetic systems, for instance, nanowires or spin valves. The origin of the CIMS mechanism in SMMs stems from angular momentum transfer between a spin-polarized current and the molecule, and it allows for …
-
Molecular and Physicochemical Characterization of Aerosols Relevant to Their Atmospheric Formation and Growth
… Ionization Ion Drift Mass Spectrometry (TD-ID-CIMS) designed for the collection and chemical analysis of nucleation to accumulation mode aerosols with sizes between 2 and 200 nm. The TD-ID-CIMS instrument has been applied to the analysis of collected nano- to sub-micrometer-sized aerosol …
-
Aqueous-phase Organic Chemistry in the Atmosphere
… Chemical Ionization Mass Spectrometry (Aerosol CIMS), was employed to quantitatively monitor aqueous-phase OH oxidation of glyoxal and methylglyoxal. Quantification of all the major reaction products was achieved, permitting complete reaction mechanisms to be presented. An unexpected class of …
-
A structured approach to production control in integrated manufacturing systems
… ln a Computer Integrated Manufacturing System (CIMS) these decisions and algorithms span several functions, require information from several sources, and have consequences in several sectors of the manufacturing system. This dissertation is concerned with the development of a structured …
-
Suscetibilidade e adaptações metabólicas do agente da cromoblastomicose Fonsecaea pedrosoi frente ao itraconazol e ao triciclazol utilizando FTIR e quimiometria
… predição das concentrações inibitórias mínimas (CIMs) do ITC para isolados de F. pedrosoi e suas respectivas adaptações metabólicas, com adição de TCZ, utilizando FTIR e análises quimiométricas. Métodos: Foram estudados 36 isolados genotipados de F. pedrosoi. A suscetibilidade ao ITC foi …
-
Calibration of a cycloidal ion mass spectrometer
… of a cycloidal type ion mass spectrometer (CIMS) for analysis of space plasmas. Crossed electric and magnetic fields are used to force incoming ions to execute cycloidal trajectories with a net displacement proportional to the mass per unit charge of the ions. The magnetic field is produced …
Page 1 of 6