Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 93 for “"CLAMPING FORCE"”
-
OPTIMAL CLAMPING FORCE ANALYSIS AND SOFTWARE IMPLEMENTATION FOR NC INTELLIGENT FIXTURING
… shortcoming still in these systems is that the clamping forces, often excessive, cannot be precisely controlled and remain constant both in locations and magnitudes. An excessive clamping force may cause distortion of a workpiece, which ultimately leads to dimensional and shape inaccuracy in …
-
The Evaluation of Performance of Spindle Connector and its Finite Element Analysis
… tilting values of the KM4X100 with the standard clamping force of 100 kN are 0.376 mm/m, 0.2755 mm/m, and 0.191 mm/m at 4600 N-m, 4100 N-m, and 3500 N-m applied bending moment, respectively. By reducing the clamping force to 80 kN, the average tool tilting value of the KM4X100 is 0.347 mm/m at …
-
Axial Clamping Behaviour of V-band clamps at Ambient and High temperature
… a V-band clamp must generate enough axial clamping load to prevent leakage at the joint. It must do this whilst being subjected to severe thermal cycling, in addition to the mechanical loads. The existing theoretical models of V-band clamps show a weak experimental correlation for low …
-
An Investigation of Bonding Formation in Ultrasonic Welding of Aluminum
… is suggested. The ef¬fects of weld time and clamping force on the weld strength were also examined. Weld strength was found to be an asymptotic increasing function of weld time and an optimal clamping force was obtained.
-
Finite Element Modeling and Analysis of the Asymmetric Friction Connection (AFC) With and Without Belleville Springs (BeSs)
… loading, including bolt-tension evolution, clamping-force variation, and sliding hysteresis. In the present research, these results were analysed in detail to identify the mechanisms governing post-sliding bolt-tension loss and to establish the optimal installed bolt pretension level. It was …
-
The effects of water displacing corrosion preventatives on the fatigue behaviour of mechanically fastened aluminium joints
… these mechanisms. The effects of lamping force, interference fit, maximum axial load and WDCP on fatigue performance of the joint are included in the models. The effect of WDCP is assumed to give a reduction in friction coefficient. Three types of stress reduction factors are proposed in …
-
Control and measurement of clamping and machining forces in intelligent fixturing
The thesis presents a novel force measurement technique in a fixturing arrangement with instrumented locators. The developed system aims to overcome the problems associated with the dynamometer and this study could lead to the feasibility of fixturing set-ups with instrumented locators as a viable …
-
Fatigue Vulnerability Analysis for existing metallic Structures
… are still in service after over 100 years. Clamping force originates when the hot rivet is placed into the hole of the plates and the rivet shorten in length due to cooling. In Europe, a large number of railway bridges are riveted. Moreover, all over the world, the rivet assembly technique …
-
SHEAR TRANSFER STRENGTH OF CONCRETE PLACED AGAINST HARDENED CONCRETE
… shear transfer mechanism. Three sets of Reinforced, un-reinforced, compressed test specimens and finite element analysis models were studied in this research, it was established that (a) ACI 318-2011 over estimates the shear strength for joints with high clamping force. (b) The shear strength …
-
Friction Spot Welding da Liga de Alumínio 6082-T6
… rotational velocity, plunge depth, weld time and clamping force. After performing the welds, a lap shear stress test was done, where the stress and displacement were measured. After this last test completed, a metallographic analysis was performed in the way of understanding the behave of the …
-
Modeling and control of switched reluctance machines for electro-mechanical brake systems
… systems. The overall goal is to design a robust clamping force controller without position sensors for the SRM. An accurate model and precisely estimated parameters are critical to the successful implementation of the control system. An inductance based model for switched reluctance machine is …
-
An Experimental Investigation of Bolt Preload Relaxation in Pultruded GFRP Composite Joints
… effects. The positive effects of increasing the clamping force in bolted joints are well known. To maintain a safe operation of the assembly a minimum clamping force must be guaranteed. But since these materials show time-dependent effects, the bolt-preload relaxes over a period of time. The …
-
Design optimization of compliant attachment mechanisms enabling frame assembly
… the design and optimization of a novel self-clamping attachment mechanism referred to as the B.R.I.D.G.E. connection (Bent Rigid Interlocking Device Guaranteeing Efficient connection). The objective was to develop a reusable, compliant connection enabling modular assembly, automated …
-
Etorinių kontaktinių lęšių padėties ant akies stabilumo tyrimas /
… on the eye crack opening, corneal shape, eyelid clamping force, as well as the refractive defect size and astigmatism axis.
Page 1 of 5